妇科肿瘤高剂量率近距离放射治疗中的交互式治疗计划

Interactive Treatment Planning in High Dose-Rate Brachytherapy for Gynecological Cancer

Huan Liu, Chang M Ma, Xun Jia, Chenyang Shen, Peter Klages, Kevin Albuquerque

摘要:

高剂量率近距离放射治疗(HDRBT)广泛用于妇科癌症治疗。尽管商业治疗计划系统(TPS)具有逆优化模块,但是需要若干迭代来调整计划目标以实现令人满意的计划。交互式计划修改模块可以实时修改计划并可视化结果,但它们基于简单的几何或启发式算法更新计划,这无法确保最终的计划最优性。本计画开发一个互动式的妇科肿瘤HDRBT计划最佳化模组。通过实时有效地解决优化问题,它允许用户可视化计划并交互式地修改它以提高质量。我们制定了一个优化问题的目标函数包含一个加权和的剂量到正常器官受用户指定的目标覆盖范围。开发了允许用户使用滚动条调整器官重量的用户界面。通过简单的鼠标点击,利用高效的交替方向乘数法和热启动优化策略,在几秒钟内即可解决优化问题。立即显示器官的临床相关D2cc结果。这允许用户以令人满意的质量直观地调整计划。我们测试了我们的开发在宫颈癌病例中的有效性,这些病例采用串联卵形敷贴器进行治疗。在每个实例中,解决优化问题最多需要3秒。通过交互优化功能,<1分钟即可获得满意的计划。在我们的诊所中,尽管使用TPS中简单的交互式计划修改工具,计划调整时间通常<10分钟,但最终的计划并不能确保最优性。我们的计划比临床计划平均低5%的D2cc,同时保持目标覆盖率。

英文摘要:

High dose-rate brachytherapy (HDRBT) is widely used for gynecological cancer treatment. Although commercial treatment planning systems (TPSs) have inverse optimization modules, it takes several iterations to adjust planning objectives to achieve a satisfactory plan. Interactive plan-modification modules enable modifying the plan and visualizing results in real time, but they update plans based on simple geometrical or heuristic algorithms, which cannot ensure resulting plan optimality. This project develops an interactive plan optimization module for HDRBT of gynecological cancer. By efficiently solving an optimization problem in real time, it allows a user to visualize a plan and interactively modify it to improve quality. We formulated an optimization problem with an objective function containing a weighted sum of doses to normal organs subject to user-specified target coverage. A user interface was developed that allows a user to adjust organ weights using scroll bars. With a simple mouse click, the optimization problem is solved in seconds with a highly efficient alternating-direction method of multipliers and a warm start optimization strategy. Resulting clinically relevant D2cc of organs are displayed immediately. This allows a user to intuitively adjust plans with satisfactory quality. We tested the effectiveness of our development in cervix cancer cases treated with a tandem-and-ovoid applicator. It took a maximum of 3 seconds to solve the optimization problem in each instance. With interactive optimization capability, a satisfactory plan can be obtained in <1 min. In our clinic, although the time for plan adjustment was typically <10min with simple interactive plan modification tools in TPS, the resulting plans do not ensure optimality. Our plans achieved on average 5% lower D2cc than clinical plans, while maintaining target coverage.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑