arXiv 2102.05953physics.med-ph
收藏

用蒙特卡罗模拟和热释光剂量计研究新型192 Ir脉冲剂量率近距离治疗源的剂量学特性

Dosimetric characterization of a new 192Ir pulse dose rate brachytherapy source with the Monte Carlo simulation and thermoluminescent dosimeter

Vahid Lohrabian, Alireza Kamali-Asl, Hossein Arabi, Hamidreza Hemmati, Majid Pournezam Esfahani

摘要:

在这项研究中,AAPM TG- 43(U1)报告的建议已被遵循,以表征新的192 Ir脉冲剂量率源,由应用辐射研究学院,核科学与技术研究所在伊朗提供。根据美国医学物理学家协会AAPM和TG 43(U1)的相关报告计算剂量率常数、径向剂量函数、几何因子和各向异性函数。本研究利用蒙特卡罗模拟对192 Ir源在水模体中的特性进行了表征,并在有机玻璃(PMMA)模体中用热释光剂量计(TOX-100)进行了实验测量。192 Ir PDR的剂量率常数分别为1.131 cGyh-1U-1和1.173 cGyh-1U-1。此外,在这项研究中,几何函数,径向剂量函数g(r),和各向异性函数已计算在距离从0.1到16厘米。这些计算的剂量率常数已与实际192 Ir种子的测量值进行了比较。剂量测定参数的结果,以表格和图形格式,表现出良好的协议,从其他市售的PDR 192 Ir来源的报告。在这项研究中获得的结果是在商业上可用的192 Ir源的特性密切一致。在这项研究中获得的结果可以被视为一个初步评估,这个来源是在传统的治疗计划系统,随后的补充调查。

英文摘要:

In this study, recommendations of the AAPM TG- 43 (U1) report have been followed to characterize the new 192Ir pulse dose rate source, provided by the Applied Radiation Research School, Nuclear Science and Technology Research Institute in Iran. Dose rate constant, radial dose function, geometry factors, and anisotropy function were calculated according to the relevant American Association of Physicists in Medicine AAPM and TG43 (U1) reports. In this study, 192Ir source was characterized using Monte Carlo simulation in water phantom, and in addition, experimental measurements were carried out using thermoluminescent dosimeters (TLD-100) in plexiglass (PMMA) phantoms. The dose-rate constant for the 192Ir PDR was found to be equal to 1.131 cGyh-1U-1 and 1.173 cGyh-1U-1 with TLD measurement and Monte Carlo simulation, respectively. Also in this study, the geometry function, radial dose functions g(r), and the anisotropy function have been calculated at distances from 0.1 to 16 cm. The dose-rate constant of these calculations has been compared with measured values for an actual 192Ir seed. The results of dosimetry parameters, presented in tabulated and graphical formats, exhibited good agreement to those reported from other commercially available PDR 192Ir sources. The results obtained in this study are in close agreement with the characteristics of the commercially available 192Ir sources. The results obtained in this study can be treated as an initial assessment of this source to be employed in the conventional treatment planning systems subsequent to complementary investigations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑