非标准高剂量率(HDR)近距离放射治疗导管模式的剂量学等效性

Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns

J. Adam M. Cunha, I-Chow Hsu, Jean Pouliot

摘要:

目的:确定替代HDR前列腺近距离放射治疗导管模式是否可以改善剂量分布,同时提供更好的入路并减少创伤。方法:前列腺HDR近距离放射治疗使用平行针位置网格来引导导管插入。这种几何形状不容易使医生避免刺穿阴茎球附近的关键结构,也不能在耻骨弓干扰的情况下提供位置灵活性。根据10名既往接受治疗的患者的CT数据,按照三种导管模式对新导管进行数字化:圆锥形、双圆锥形和烟花形。锥形图案用于适应使用单个入口点的机器人递送。双锥形和烟花图案是专门设计的,以避免阴茎球附近的关键结构。对于每种导管分布,使用反向规划算法IPSA优化计划,并与治疗所用计划进行比较。与导管几何结构无关,计划必须满足RTOG-0321目标剂量覆盖的剂量标准。结果:优化了10例患者的30个方案。所有非标准模式符合RTOG标准,而临床计划符合。在某些情况下,通过更好地保留危险器官来改善剂量分布。结论:替代导管模式可以为医生提供额外的方法来治疗先前被认为不适合近距离放射治疗的患者(耻骨弓干扰),并促进导管插入的机器人引导。此外,替代导管模式可通过避开阴茎球附近的关键结构来降低毒性,同时仍满足RTOG标准。

英文摘要:

Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. On CT data from ten previously-treated patients new catheters were digitized following three catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage. Results: Thirty plans from ten patients were optimized. All non-standard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑