arXiv 2108.07113physics.med-ph
收藏

具有有限角范围数据的双能量CT成像

Dual-energy CT imaging with limited-angular-range data

Buxin Chen, Zheng Zhang, Dan Xia, Emil Y. Sidky, Xiaochuan Pan

摘要:

在双能量计算机断层成像(DECT)中,通常在$360^\circ$的全角度范围(FAR)上收集低kVp和高kVp数据。虽然存在强烈的兴趣,在DECT与低和高kVp的数据采集有限的角度范围(LARs),仍然很少有调查的图像重建DECT与LAR数据。目的:我们研究图像重建与最小化LAR伪影从低和高kVp数据的LARs的$\le 180^\circ$通过使用方向全变分(DTV)算法。研究方法:从LAR数据的图像重建公式化为凸优化问题,其中数据- $\ell_2$最小化与约束的图像的DTV沿正交轴。然后,我们通过应用DTV算法来解决优化问题,实现图像重建。我们进行数值研究,从弧的LARs产生的数据,从$14^\circ$到$180^\circ$,并进行目视检查和定量分析重建的图像。结果如下:用DTV算法从LAR数据获得的感兴趣的单色图像显示出在用现有算法获得的图像中经常观察到的大幅减少的伪影。改进的图像质量还导致对感兴趣的物理量的准确估计,诸如有效原子序数和碘造影剂浓度。结论:我们的研究表明,从低和高kVp的LAR数据,单色图像可以获得视觉上,和物理量可以估计是定量的,在FAR DECT中获得的。重要性:由于LAR DECT具有很高的实际应用价值,因此本文的研究结果对设计具有实际应用意义的LAR扫描结构的DECT具有重要意义。

英文摘要:

In dual-energy computed tomography (DECT), low- and high- kVp data are collected often over a full-angular range (FAR) of $360^\circ$. While there exists strong interest in DECT with low- and high-kVp data acquired over limited-angular ranges (LARs), there remains little investigation of image reconstruction in DECT with LAR data. Objective: We investigate image reconstruction with minimized LAR artifacts from low- and high-kVp data over LARs of $\le 180^\circ$ by using a directional-total-variation (DTV) algorithm. Methods: Image reconstruction from LAR data is formulated as a convex optimization problem in which data-$\ell_2$ is minimized with constraints on image's DTVs along orthogonal axes. We then achieve image reconstruction by applying the DTV algorithm to solve the optimization problem. We conduct numerical studies from data generated over arcs of LARs, ranging from $14^\circ$ to $180^\circ$, and perform visual inspection and quantitative analysis of images reconstructed. Results: Monochromatic images of interest obtained with the DTV algorithm from LAR data show substantially reduced artifacts that are observed often in images obtained with existing algorithms. The improved image quality also leads to accurate estimation of physical quantities of interest, such as effective atomic number and iodine-contrast concentration. Conclusion: Our study reveals that from LAR data of low- and high-kVp, monochromatic images can be obtained that are visually, and physical quantities can be estimated that are quantitatively, comparable to those obtained in FAR DECT. Significance: As LAR DECT is of high practical application interest, the results acquired in the work may engender insights into the design of DECT with LAR scanning configurations of practical application significance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑