We present two fiberized vector magnetic-field sensors, based on nitrogen-vacancy (NV) centers in diamond. The sensors feature sub-nT/$\sqrt{\textrm{Hz}}$ magnetic sensitivity. We use commercially available components to construct sensors with a small sensor size, high photon collection, and minimal sensor-sample distance. Both sensors are located at the end of optical fibres with the sensor-head freely accessible and robust under movement. These features make them ideal for mapping magnetic fields with high sensitivity and spatial resolution ($\leq$\,mm). As a demonstration we use one of the sensors to map the vector magnetic field inside the bore of a $\geq$ 100\,mT Halbach array. The vector field sensing protocol translates microwave spectroscopy data addressing all diamonds axes and including double quantum transitions to a 3D magnetic field vector.
We present an experimental method to perform dual-channel lock-in magnetometry of time-dependent magnetic fields using a single spin associated with a nitrogen-vacancy (NV) color center in diamond. We incorporate multi-pulse quantum sensing sequences with phase estimation algorithms to achieve linearized field readout and constant, nearly decoherence-limited sensitivity over a wide dynamic range. Furthermore, we demonstrate unambiguous reconstruction of the amplitude and phase of the magnetic field. We show that our technique can be applied to measure random phase jumps in the magnetic field, …
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for…
Improved constraints on exotic spin-dependent interactions are established at the micrometer scale by a magnetometer with ensembles of nitrogen-vacancy (NV) centers in diamond. A thin layer of NV electronic spin ensembles is utilized as the sensor, and a lead sphere is taken as the source of the nucleons. The exotic spin-dependent interactions are explored by detecting the possible effective magnetic fields by the sensor. Stringent bounds on an exotic parity-odd spin- and velocity-dependent interaction are set within the force range from 5 to 500 $μ$m. The upper limit of the corresponding coup…
Nitrogen-vacancy quantum defects in diamond offer a promising platform for magnetometry because of their remarkable optical and spin properties. In this Letter, we present a high-sensitivity and wide-bandwidth fiber-based quantum magnetometer for practical applications. By coating the diamond surface with silver reflective film, both the fluorescence collection and excitation efficiency are enhanced. Additionally, tracking pulsed optically detected magnetic resonance spectrum allowed a magnetic field sensitivity of $35$ pT$/\sqrt{\rm{Hz}}$ and a bandwidth of $4.1$ KHz. Finally, this magnetomet…
A Highly Sensitive Diamond NV Magnetometer Using Ramsey Interferometry with a Short Sensor-to-Sample Distance
Institute of Science Tokyo(东京科学大学);National Institute for Materials Science(国立材料研究所);University of Tsukuba(筑波大学);National Institutes for Quantum Science and Technology(国立量子科学技术研究院);Tohoku University(东北大学);DENSO CORPORATION(电装株式会社)
Diamond defect centers are promising solid state magnetometers. Single centers allow for high spatial resolution field imaging but are limited in their magnetic field sensitivity to around 10 nT/Hz^(1/2) at room-temperature. Using defect center ensembles sensitivity can be scaled as N^(1/2) when N is the number of defects. In the present work we use an ensemble of 1e11 defect centers for sensing. By carefully eliminating all noise sources like laser intensity fluctuations, microwave amplitude and phase noise we achieve a photon shot noise limited field sensitivity of 0.9 pT/Hz^(1/2) at room-te…
The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as $110\%$. The sensitivity of the magnetometer with NV center ense…
Magnetic field sensors that exploit quantum effects have shown that they can outperform classical sensors in terms of sensitivity enabling a range of novel applications in future, such as a brain machine interface. Negatively charged nitrogen-vacancy (NV) centers in diamond have emerged as a promising high sensitivity platform for measuring magnetic fields at room temperature. Transferring this technology from laboratory setups into products and applications, the total size of the sensor, the overall power consumption, and the costs need to be reduced and optimized. Here, we demonstrate a fibe…
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in diamond is limited by number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4e-3 mm$^3$. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers…
We describe here the construction and characterization of a high-resolution optical magnetometer to measure the full vector magnetic field on an ultrathin layer near the surface of the device. This solid-state device is based on quantum sensors created by a layer of nitrogen-vacancy (NV) centers less than 20 nm below the surface of an ultrapure diamond. This ensemble of nanosensors provides a versatile device capable of mapping magnetic fields and surface current densities with a sub-micrometer resolution and high sensitivity, making it suitable for many applications. Here, we show a custom-bu…
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\…
Diamond nitrogen-vacancy (NV) center magnetometry has recently received considerable interest from researchers in the fields of applied physics and sensors. The purpose of this review is to analyze the principle, sensitivity, technical development potential, and application prospect of the diamond NV center magnetometry. This review briefly introduces the physical characteristics of NV centers, summarizes basic principles of the NV center magnetometer, analyzes the theoretical sensitivity, and discusses the impact of technical noise on the NV center magnetometer. Furthermore, the most critical…
Magnetic Resonance Imaging (MRI) can characterize and discriminate among tissues using their diverse physical and biochemical properties. Unfortunately, submicrometer screening of biological specimens is presently not possible, mainly due to lack of detection sensitivity. Here we analyze the use of a nitrogen-vacancy center in diamond as a magnetic sensor for nanoscale nuclear spin imaging and spectroscopy. We examine the ability of such a sensor to probe the fluctuations of the "classical" dipolar field due to a large number of neighboring nuclear spins in a densely protonated sample. We iden…
We report a new method to determine the orientation of individual nitrogen-vacancy (NV) centers in a bulk diamond and use them to realize a calibration-free vector magnetometer with nanoscale resolution. Optical vortex beam is used for optical excitation and scanning the NV center in a [111]-oriented diamond. The scanning fluorescence patterns of NV center with different orientations are completely different. Thus, the orientation information on each NV center in the lattice can be known directly without any calibration process. Further, we use three differently oriented NV centers to form a m…
Squeezing for dispersive readout of NV magnetometer
Russian Quantum Center(俄罗斯量子中心);Moscow Institute of Physics and Technology(莫斯科物理工程技术学院);P.N.Lebedev Physical Institute of the Russian Academy of Science(俄罗斯科学院列别杰夫物理研究所);LLC Sensor Spin Technologies(传感器自旋技术有限责任公司)
Nanoscale electronic transport gives rise to a number of intriguing physical phenomena that are accompanied by distinct spatial patterns of current flow. Here, we report on sensitive magnetic imaging of two-dimensional current distributions in bilayer graphene at room temperature. By combining dynamical modulation of the source-drain current with ac quantum sensing of a nitrogen-vacancy center in a diamond probe, we acquire magnetic field and current density maps with excellent sensitivities of 4.6 nT and 20 nA/$μ$m, respectively. The spatial resolution is 50-100 nm. We further introduce a set…
In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV magnetometer attained a magnetic sensitivity of $4.3 ~ \mathrm{nT} / \sqrt{\mathrm{Hz}}$ and a volume-normalized sensitivity of $3.6 ~ \mathrm{pT} / \sqrt{\mathrm{Hz} \cdot \mathrm{mm}^{-3}}$, which are 5 times better than the already existing method under the same conditions. Based on the proposed magnetometer configuration, a burst eddy current (BEC) testing…
New magnetometry techniques based on Nitrogen Vacancy (NV) defects in diamond have received much attention of late as a means to probe nanoscale magnetic environments. The sensitivity of a single NV magnetometer is primarily determined by the transverse spin relaxation time, $T_2$. Current approaches to improving the sensitivity employ crystals with a high NV density at the cost of spatial resolution, or extend $T_2$ via the manufacture of novel isotopically pure diamond crystals. We adopt a complementary approach, in which optimal dynamic decoupling techniques extend coherence times out to th…
Human Cardiac Measurements with Diamond Magnetometers
Helmholtz-Institut Mainz, GSI Helmholtzzentrum für Schwerionenforschung(亥姆霍兹美因茨研究所,GSI重离子研究中心);Johannes Gutenberg-Universität Mainz(约翰内斯·古腾堡美因茨大学);Zentrum für Angewandte Quantumtechnologie (ZAQuant), University of Stuttgart(斯图加特大学应用量子技术中心)
Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrica…
Wide field-of-view magnetic field microscopy has been realised by probing shifts in optically detected magnetic resonance (ODMR) spectrum of Nitrogen Vacancy (NV) defect centers in diamond. However, these widefield diamond NV magnetometers require few to several minutes of acquisition to get a single magnetic field image, rendering the technique temporally static in it's current form. This limitation prevents application of diamond NV magnetometers to novel imaging of dynamically varying microscale magnetic field processes. Here, we show that the magnetic field imaging frame rate can be signif…
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-freq…
Nitrogen vacancy (NV) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors. However, high sensitivity measurements usually come with additional constraints on the pumping intensity of the laser and the pulse control applied. Here, we demonstrate high sensitivity NV ensemble based magnetic field measurements with low-intensity optical excitation. DC magnetometry methods like, e.g., continuous-wave optically detected magnetic resonance and continuously excited Ramsey measurements combined with lock-in detection, are compared to get an optimization. G…
A single nitrogen-vacancy (NV) center in diamond is a prime candidate for a solid-state quantum magnetometer capable of detecting single nuclear spins with prospective application to nuclear magnetic resonance (NMR) at the nanoscale. Nonetheless, an NV magnetometer is still less accessible to many chemists and biologists, as its experimental setup and operational principle are starkly different from those of conventional NMR. Here, we design, construct, and operate a compact tabletop-sized system for quantum sensing with a single NV center, built primarily from commercially available optical c…
Wideband microwave resonator for NV center vector magnetometry
P.N. Lebedev Institute RAS(俄罗斯科学院列别杰夫物理研究所);LLC Diamond Sensors(钻石传感器有限责任公司);Faculty of Physics and Engineering, ITMO University(ITMO大学物理与工程学院);Russian Quantum Center(俄罗斯量子中心);Moscow Institute of Physics and Technology(莫斯科物理技术学院);National Research Nuclear University “MEPhI”(国立研究核大学“莫斯科工程物理学院”);B.I. Stepanov Institute of Physics NASB(白俄罗斯国家科学院B.I.斯捷潘诺夫物理研究所)
Recently, magnetic field sensors based on an electron spin of a nitrogen vacancy (NV) center in diamond have been studied both from an experimental and theoretical point of view. This system provides a nanoscale magnetometer, and it is possible to detect a precession of a single spin. In this paper, we propose a sensor consisting of an electron spin and a nuclear spin in diamond. Although the electron spin has a reasonable interaction strength with magnetic field, the coherence time of the spin is relatively short. On the other hand, the nuclear spin has a longer life time while the spin has a…
Millimeter-scale rigid diamond probe for high sensitivity endoscopic-magnetometry applications
School of Instrumentation and Optoelectronic Engineering, Beihang University(北京航空航天大学仪器科学与光电工程学院);Beijing Quantum Technology Research and Development Center(北京量子技术研发中心)
Magnetic sensing and imaging instruments are important tools in biological and material sciences. There is an increasing demand for attaining higher sensitivity and spatial resolution, with implementations using a single qubit offering potential improvements in both directions. In this article we describe a scanning magnetometer based on the nitrogen-vacancy center in diamond as the sensor. By means of a quantum-assisted readout scheme together with advances in photon collection efficiency, our device exhibits an enhancement in signal to noise ratio of close to an order of magnitude compared t…
Developing robust microwave-field sensors is both fundamentally and practically important with a wide range of applications from astronomy to communication engineering. The Nitrogen-Vacancy (NV) center in diamond is an attractive candidate for such purpose because of its magnetometric sensitivity, stability and compatibility with ambient conditions. However, the existing NV center-based magnetometers have limited sensitivity in the microwave band. Here we present a continuous heterodyne detection method that can enhance the sensor's response to weak microwaves, even in the absence of spin cont…
In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties of a thin-layer yttrium barium copper oxide (YBCO) superconductor. Using fluorescence-microscopy methods and samples integrated with an NV sensor on a microchip, we measure the temperature of phase tr…
We demonstrate a vector magnetometer that simultaneously measures all Cartesian components of a dynamic magnetic field using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond. Optical NV-diamond measurements provide high-sensitivity, broadband magnetometry under ambient or extreme physical conditions; and the fixed crystallographic axes inherent to this solid-state system enable vector sensing free from heading errors. In the present device, multi-channel lock-in detection extracts the magnetic-field-dependent spin resonance shifts of NVs oriented along all four tetrahed…
We demonstrate room temperature detection of single 20 nm super-paramagnetic nanoparticles (SPNs) with a wide-field optical microscope platform suitable for biological integration. The particles are made of magnetite (Fe3O4) and are thus non-toxic and biocompatible. Detection is accomplished via optically detected magnetic resonance imaging using nitrogen-vacancy defect centers in diamond, resulting in a DC magnetic field detection limit of 2.3 μT. This marks a large step forward in the detection of SPNs, and we expect that it will allow for the development of magnetic-field-based biosensors c…
Single-Spin Nitrogen-Vacancy Hybrid Magnetometer with Enhanced Static Field Sensitivity
University of Calgary(卡尔加里大学);Max Planck Institute for Biophysical Chemistry(马克斯·普朗克生物物理化学研究所);Sichuan University of Science and Engineering(四川理工学院);QNeura;VinUniversity(越南大学);XeedQ GmbH(XeedQ有限公司)
Here, we demonstrate a gradiometry technique that significantly enhances the measurement sensitivity of such static fields, leading to new opportunities in the imaging of weakly magnetic systems. Our method relies on the mechanical oscillation of a single nitrogen-vacancy center at the tip of a scanning diamond probe, which up-converts the local spatial gradients into ac magnetic fields enabling the use of sensitive ac quantum protocols. We show that gradiometry provides important advantages over static field imaging: (i) an order-of-magnitude better sensitivity, (ii) a more localized and shar…
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynamic range; and allows for simultaneous interrogation of multiple transition frequencies. By directly detecting the resonance frequencies of NV centers aligned along each of the diamond's four tetrahedra…
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4\,mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption…