In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV magnetometer attained a magnetic sensitivity of $4.3 ~ \mathrm{nT} / \sqrt{\mathrm{Hz}}$ and a volume-normalized sensitivity of $3.6 ~ \mathrm{pT} / \sqrt{\mathrm{Hz} \cdot \mathrm{mm}^{-3}}$, which are 5 times better than the already existing method under the same conditions. Based on the proposed magnetometer configuration, a burst eddy current (BEC) testing prototype achieves a minimum detectable sample smaller than ${300~μ \mathrm{m}}$ and measurement accuracy of $9.85~\mathrmμ \mathrm{m}$., which is employed to image different metallic specimens and detect the layered internal structures. Since our prototype comprises superb high sensitivity, it exhibits various potential applications in the fields of deformation monitoring, security screening, and quality control. Moreover, its biocompatibility and promising nanoscale resolution paves the way for electromagnetic testing in the fields of biomaterials.
Ensembles of nitrogen-vacancy (NV) centers in diamonds are widely utilized for magnetometry, magnetic-field imaging and magnetic-resonance detection. They have not been used for magnetometry at zero ambient field because Zeeman sublevels lose first-order sensitivity to magnetic fields as they are mixed due to crystal strain or electric fields. In this work, we realize a zero-field (ZF) magnetometer using polarization-selective microwave excitation in a 12C-enriched HPHT crystal sample. We employ circularly polarized microwaves to address specific transitions in the optically detected magnetic …
Nitrogen vacancy (NV) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors. However, high sensitivity measurements usually come with additional constraints on the pumping intensity of the laser and the pulse control applied. Here, we demonstrate high sensitivity NV ensemble based magnetic field measurements with low-intensity optical excitation. DC magnetometry methods like, e.g., continuous-wave optically detected magnetic resonance and continuously excited Ramsey measurements combined with lock-in detection, are compared to get an optimization. G…
Diamond nitrogen-vacancy (NV) center magnetometry has recently received considerable interest from researchers in the fields of applied physics and sensors. The purpose of this review is to analyze the principle, sensitivity, technical development potential, and application prospect of the diamond NV center magnetometry. This review briefly introduces the physical characteristics of NV centers, summarizes basic principles of the NV center magnetometer, analyzes the theoretical sensitivity, and discusses the impact of technical noise on the NV center magnetometer. Furthermore, the most critical…
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is calculated as 8$\times 10 ^{5}$\,S/m\,$\sqrt[]{\textrm{Hz}}$ at 3.5\,MHz, for a cylindrical sample with radius $r_0$\,=\,1\,mm and height $h$\,=\,0.1\,mm (volume $\sim$\,0.3\,mm$^3$), at a distance of…
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for…
Detection of AC magnetic fields at the nanoscale is critical in applications ranging from fundamental physics to materials science. Isolated quantum spin defects, such as the nitrogen-vacancy center in diamond, can achieve the desired spatial resolution with high sensitivity. Still, vector AC magnetometry currently relies on using different orientations of an ensemble of sensors, with degraded spatial resolution, and a protocol based on a single NV is lacking. Here we propose and experimentally demonstrate a protocol that exploits a single NV to reconstruct the vectorial components of an AC ma…
Millimeter-scale rigid diamond probe for high sensitivity endoscopic-magnetometry applications
School of Instrumentation and Optoelectronic Engineering, Beihang University(北京航空航天大学仪器科学与光电工程学院);Beijing Quantum Technology Research and Development Center(北京量子技术研发中心)
Solid-state spin systems including nitrogen-vacancy (NV) centers in diamond constitute an increasingly favored quantum sensing platform. However, present NV ensemble devices exhibit sensitivities orders of magnitude away from theoretical limits. The sensitivity shortfall both handicaps existing implementations and curtails the envisioned application space. This review analyzes present and proposed approaches to enhance the sensitivity of broadband ensemble-NV-diamond magnetometers. Improvements to the spin dephasing time, the readout fidelity, and the host diamond material properties are ident…
Sensing small magnetic fields is relevant for many applications ranging from geology to medical diagnosis. We present a fiber-coupled diamond magnetometer with a sensitivity of (310 $\pm$ 20) pT$/\sqrt{\text{Hz}}$ in the frequency range of 10-150 Hz. This is based on optically detected magnetic resonance of an ensemble of nitrogen vacancy centers in diamond at room temperature. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study.
The nitrogen vacancy (NV) center in diamond has emerged as a leading solid-state quantum sensor for applications including magnetometry, electrometry, thermometry, and chemical sensing. However, an outstanding challenge for practical applications is that existing NV-based sensing techniques require bulky and discrete instruments for spin control and detection. Here, we address this challenge by integrating NV based quantum sensing with complementary metal-oxide-semiconductor (CMOS) technology. Through tailored CMOS-integrated microwave generation and photodetection, this work dramatically redu…
Unconditional full vector magnetometry using spin selectivity in Nitrogen Vacancy centers in diamond
University of the Basque Country(巴斯克大学);Centro de Fisica de Materiales (CFM), CSIC-UPV/EHU(材料物理中心,西班牙国家研究委员会/巴斯克大学);Donostia International Physics Center(圣塞巴斯蒂安国际物理中心);IKERBASQUE, Basque Foundation for Science(伊卡巴斯基克,巴斯克科学基金会)
The NV center in a diamond is a quantum sensor with exceptional quality for highly sensitive nanoscale analysis of NMR spectra and thermometry. In this study, we investigate nanoscale phase change detection of lipid bilayers utilizing ensemble-averaged nuclear spin detection from small volume ~ (6 nm)$^{3}$, which was determined by the depth of the NV center. Analysis of nanoscale NMR signal confirm thickness of lipid bilayer to be 6.2 nm $\pm$ 3.4 nm with proton density of 65 proton/nm$^{3}$ verifying formation of lipid bilayer on top of diamond sample. Correlation spectroscopy from nanoscale…
Magnetic field sensing, with its recent advances, is emerging as a viable alternative to measure functional activity of single neurons in the brain by sensing action potential associated magnetic fields (APMFs). Measurement of APMFs of large axons of worms have been possible due to their size. In the mammalian brain, axon sizes, their numbers and routes, restricts using such functional imaging methods. With segmented model of mammalian pyramidal neurons, we show that the APMF of intra-axonal currents in the axon hillock are two orders of magnitude larger than other neuronal locations. Expected…
Nitrogen-vacancy quantum defects in diamond offer a promising platform for magnetometry because of their remarkable optical and spin properties. In this Letter, we present a high-sensitivity and wide-bandwidth fiber-based quantum magnetometer for practical applications. By coating the diamond surface with silver reflective film, both the fluorescence collection and excitation efficiency are enhanced. Additionally, tracking pulsed optically detected magnetic resonance spectrum allowed a magnetic field sensitivity of $35$ pT$/\sqrt{\rm{Hz}}$ and a bandwidth of $4.1$ KHz. Finally, this magnetomet…
Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing, promising increased sensitivity for applications ranging from geophysics to biomedicine. Conventional sensing schemes involve monitoring the change in red fluorescence from the NV center under green laser and microwave illumination. Due to the strong fluorescence background from emission in the NV triplet state and low relative contrast of any change in output, sensitivity is severely restricted by a high optical shot noise level. Here, we propose a means to avoid this issue, by usi…
Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries in a noninvasive detection. We demonstrate a microwave-free AC magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between NV centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructive solid-state battery imaging. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the externa…
Scanning diamond magnetometers based on the optically detected magnetic resonance of the nitrogen-vacancy centre offer very high sensitivity and non-invasive imaging capabilities when the stray fields emanating from ultrathin magnetic materials are sufficiently low (< 10 mT). Beyond this low-field regime, the optical signal quenches and a quantitative measurement is challenging. While the field-dependent NV photoluminescence can still provide qualitative information on magnetic morphology, this operation regime remains unexplored particularly for surface magnetisation larger than $\sim$ 3 mA. …
Engineering a layer of nitrogen-vacancy (NV) centers on the tip of a diamond anvil creates a multipurpose quantum sensors array for high pressure measurements, especially for probing magnetic and superconducting properties of materials. Expanding this concept above 100 GPa appears to be a substantial challenge. We observe that deviatoric stress on the anvil tip sets a limit at 40-50 GPa for practical magnetic measurements based on optically detected magnetic resonance (ODMR) of NV centers under pressure. We show that this limit can be circumvented up to at least 130 GPa by machining a micropil…
Sensing vector magnetic fields is critical to many applications in fundamental physics, bioimaging, and material science. Magnetic-field sensors exploiting nitrogen-vacancy (NV) centers are particularly compelling as they offer high sensitivity and spatial resolution even at nanoscale. Achieving vector magnetometry has, however, often required applying microwaves sequentially or simultaneously, limiting the sensors' applications under cryogenic temperature. Here we propose and demonstrate a microwave-free vector magnetometer that simultaneously measures all Cartesian components of a magnetic f…
We demonstrate a vector magnetometer that simultaneously measures all Cartesian components of a dynamic magnetic field using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond. Optical NV-diamond measurements provide high-sensitivity, broadband magnetometry under ambient or extreme physical conditions; and the fixed crystallographic axes inherent to this solid-state system enable vector sensing free from heading errors. In the present device, multi-channel lock-in detection extracts the magnetic-field-dependent spin resonance shifts of NVs oriented along all four tetrahed…
The negatively-charged NV$^-$-center in diamond has shown great success in nanoscale, high-sensitivity magnetometry. Efficient fluorescence detection is crucial for improving the sensitivity. Furthermore, integrated devices enable practicable sensors. Here, we present a novel architecture which allows us to create NV$^-$-centers a few nanometers below the diamond surface, and at the same time in the mode field maximum of femtosecond-laser-written type-II waveguides. We experimentally verify the coupling efficiency, showcase the detection of magnetic resonance signals through the waveguides and…
Diamond containing the negatively charged nitrogen-vacancy (NV) center is emerging as a significant new system for magnetometry. However, most NV sensors require microscopes to collect the fluorescence signals and are therefore limited to laboratory settings. By incorporating micron-scale diamond particles at an annular interface within the cross section of a silicate glass fiber, a high-sensitivity and robust fiber platform for magnetic field sensing is demonstrated here. The fluorescence and spin properties of NV centers embedded in the diamond crystals are well preserved during the fiber dr…
Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrica…
Nitrogen-vacancy (NV) quantum magnetometers offer exceptional sensitivity and long-term stability. However, their use to date in distributed sensing applications, including remote detection of ferrous metals, geophysics, and biosensing, has been limited due to the need to combine optical, RF, and magnetic excitations into a single system. Existing approaches have yielded localized devices but not distributed capabilities. In this study, we report on a continuous system-in-a-fiber architecture that enables distributed magnetic sensing over extended lengths. Key to this realization is a thermall…