基于深度学习的个体化三维剂量分布预测可行性研究

A Feasibility Study on Deep Learning Based Individualized 3D Dose Distribution Prediction

Jianhui Ma, Dan Nguyen, Ti Bai, Michael Folkerts, Xun Jia, Weiguo Lu, Linghong Zhou, Steve Jiang

摘要:

目的:放射治疗计划是一个反复试验的过程,通常很耗时。基于特定解剖结构的最佳剂量分布可以通过预先训练的深度学习(DL)模型来预测。然而,剂量分布通常不仅基于患者特定的解剖结构进行优化,而且还基于医生在计划靶体积(PTV)覆盖和风险器官(OAR)保留之间的优选权衡进行优化。因此,期望允许医师微调基于患者解剖结构预测的剂量分布。在这项工作中,我们开发了一个DL模型来预测个体化的三维剂量分布,不仅使用解剖结构,而且还使用所需的PTV/OAR权衡,如剂量体积直方图(DVH)所表示的,作为输入。研究方法:所需的DVH,微调医生从最初预测的DVH,首先投影到帕累托表面上,然后转换成一个矢量,然后与掩模特征图连接。用于训练的网络输出是对应于Pareto最优DVH的剂量分布。训练/验证数据集包含77名前列腺癌患者,测试数据集包含20名患者。结果:训练后的模型可以预测近似Pareto最优的3D剂量分布。我们计算了PTV和所有OAR的预测和优化剂量分布之间的差异,作为定量评价。平均剂量的最大平均误差约为处方剂量的1.6%,最大剂量的最大平均误差约为1.8%。结论:在这项可行性研究中,我们开发了一个3D U-Net模型,将解剖结构和所需的DVH作为输入,以预测个性化的3D剂量分布。预测的剂量分布可作为剂量师和医生快速制定临床可接受的治疗计划的参考。

英文摘要:

Purpose: Radiation therapy treatment planning is a trial-and-error, often time-consuming process. An optimal dose distribution based on a specific anatomy can be predicted by pre-trained deep learning (DL) models. However, dose distributions are often optimized based on not only patient-specific anatomy but also physician preferred trade-offs between planning target volume (PTV) coverage and organ at risk (OAR) sparing. Therefore, it is desirable to allow physicians to fine-tune the dose distribution predicted based on patient anatomy. In this work, we developed a DL model to predict the individualized 3D dose distributions by using not only the anatomy but also the desired PTV/OAR trade-offs, as represented by a dose volume histogram (DVH), as inputs. Methods: The desired DVH, fine-tuned by physicians from the initially predicted DVH, is first projected onto the Pareto surface, then converted into a vector, and then concatenated with mask feature maps. The network output for training is the dose distribution corresponding to the Pareto optimal DVH. The training/validation datasets contain 77 prostate cancer patients, and the testing dataset has 20 patients. Results: The trained model can predict a 3D dose distribution that is approximately Pareto optimal. We calculated the difference between the predicted and the optimized dose distribution for the PTV and all OARs as a quantitative evaluation. The largest average error in mean dose was about 1.6% of the prescription dose, and the largest average error in the maximum dose was about 1.8%. Conclusions: In this feasibility study, we have developed a 3D U-Net model with the anatomy and desired DVH as inputs to predict an individualized 3D dose distribution. The predicted dose distributions can be used as references for dosimetrists and physicians to rapidly develop a clinically acceptable treatment plan.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑