稀疏概率评估用于治疗计划:一项在IMPT头颈患者中的可行性研究

Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients

Erasmus MC Cancer Institute(伊拉斯谟斯癌症研究所);HollandPTC(荷兰PTC);Leiden University Medical Center(莱顿大学医学中心);RaySearch laboratories(雷搜索实验室)

Jenneke I. de Jong, Steven J. M. Habraken, Albin Fredriksson, Johan Sundström, Erik Engwall, Sebastiaan Breedveld, Mischa S. Hoogeman

AI总结:

本研究提出稀疏概率评估方法,用于提高IMPT治疗计划中目标覆盖与器官保护的平衡,通过优化网格设置实现高效计算,验证了其在头颈癌患者中的可行性。

摘要:

概率评估改善了IMPT中目标覆盖与OAR保护之间的权衡,但计算上仍具有挑战性。本研究提出了一种计算高效的稀疏概率评估(SPE)方法,该方法集成到临床治疗计划系统中。纳入了2024年治疗的20例IMPT头颈癌患者临床计划。SPE使用预定义的设置和范围误差网格,并通过蒙特卡洛计算剂量分布。评估了两种网格设置:最大误差Emax(3σ或4σ)和设置误差点数nsetup(7、33、123)。在校准组(5名患者)中,评估了每个网格下SPE的准确性和持续时间。模拟了1000次治疗,其中随机误差(σ=1 mm)和系统误差(σ=0.92 mm)均按正态分布。每个分数分配最近的误差点在网格中的剂量分布。SPE导出的概率分布与基于35,000次蒙特卡洛计算的参考进行比较。找到的最优网格(Emax=3σ,nsetup=33)应用于验证组(15名患者)。在校准组中,SPE的准确性随着误差点数从7(tavg=2分钟)增加到33(tavg=9分钟)显著提高,33到123个误差点之间无进一步改进(tavg=27分钟)。仅当Emax值超过第98百分位数时,增加Emax才提高准确性。将SPE应用于验证组,得到10th百分位数D99.8% CTV分布的中位误差为0.02 Gy RBE(范围:-0.11至0.07),95th百分位数D0.03cc,SpinalCord Core分布的中位误差为0.0 Gy RBE(范围:-0.14至0.23)。稀疏概率评估在要求临床可接受的计算时间的同时实现了足够的准确性,为临床实践中概率评估铺平了道路。

英文摘要:

Probabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS. Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients). Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution. Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑