使用3D打印的拟人头颈体模验证Monte Carlo碘-131放射性药物剂量测定工作流程
Validation of Monte Carlo Iodine-131 radiopharmaceutical dosimetry workflow using a 3D printed anthropomorphic head and neck phantom
摘要:
目的:在这项研究中,我们提出了一个拟人的,头部和颈部,核医学体模的创建及其表征的蒙特卡罗,SPECT图像为基础的,碘-131 RPT剂量测定工作流程的验证。方法:使用3D打印技术从患者CT数据集创建拟人化体模。使用均质、Jaszczak和拟人化体模进行三次碘-131 SPECT/CT成像研究,以量化SPECT图像。使用基于图像的Geant 4 Monte Carlo RPT剂量测定工作流程计算准直器探测器响应(CDR)建模和基于体积的部分体积校正(PVC)对吸收剂量的影响,并与真实场景进行比较。最后,根据最近的EANM指南量化了不确定性。结果:3D打印的拟人化体模是对患者解剖结构(包括骨骼)的准确再现。对于CDR和非CDR情况,外推的Jaszczak回收系数大于3D打印插入物的回收系数(约22.8 ml)。利用Jaszczak体模PVC,在无CDR和有CDR的情况下,吸收剂量分别被低估0.7%和4.9%。使用拟人体模RC,在有和没有CDR的情况下,对吸收剂量的预测均超出3%。包含PVC的所有剂量测定方案均在计算的放射性不确定度范围内。对于体积为0.5 ml至16 ml的Jaszczak球,累积活性的不确定度范围为25.6%至113%。结论:使用拟人体模验证了基于蒙特卡罗的头颈部癌131碘RPT剂量学的准确性。体模的未来应用可能涉及3D打印和表征患者特定体积,以进行更个性化的RPT剂量测定估计。
英文摘要:
Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow. Methods: 3D printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three Iodine-131 SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images. The impact of collimator detector response (CDR) modeling and volume-based partial volume corrections (PVC) upon the absorbed dose was calculated using an image based, Geant4 Monte Carlo RPT dosimetry workflow and compared against a ground truth scenario. Finally, uncertainties were quantified in accordance with recent EANM guidelines. Results: The 3D printed anthropomorphic phantom was an accurate re-creation of patient anatomy including bone. The extrapolated Jaszczak recovery coefficients were greater than that of the 3D printed insert (~22.8 ml) for both the CDR and non-CDR cases. Utilizing Jaszczak phantom PVCs, the absorbed dose was underpredicted by 0.7% and 4.9% without and with CDR, respectively. Utilizing anthropomorphic phantom RCs overpredicted the absorbed dose by 3% both with and without CDR. All dosimetry scenarios that incorporated PVC were within the calculated uncertainty of the activity. The uncertainties in the cumulative activity ranged from 25.6% to 113% for Jaszczak spheres ranging in volume from 0.5 ml to 16 ml. Conclusion: The accuracy of Monte Carlo-based dosimetry for Iodine-131 RPT in head and neck cancer was validated with an anthropomorphic phantom. Future applications of the phantom could involve 3D printing and characterizing patient specific volumes for more personalized RPT dosimetry estimates.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。