While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary example. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) system design integrating conventional spiral cone-beam CT, contemporary interior tomography, deep learning techniques, and technologies of micro-focus X-ray source, photon-counting detector (PCD), and robotic arms for ultrahigh resolution localized tomography of a freely-selected volume of interest (VOI) at a minimized radiation dose level. The whole system consists of a standard CT scanner for a clinical CT exam and VOI specification, and a robotic-arm based micro-CT scanner for a local scan at much higher spatial and spectral resolution as well as much reduced radiation dose. The prior information from global scan is also fully utilized for background compensation to improve interior tomography from local data for accurate and stable VOI reconstruction. Our results and analysis show that the proposed hybrid reconstruction algorithm delivers superior local reconstruction, being insensitive to the misalignment of the isocenter position and initial view angle in the data/image registration while the attenuation error caused by scale mismatch can be effectively addressed with bias correction. These findings demonstrate the feasibility of our system design. We envision that deep learning techniques can be leveraged for optimized imaging performance. With high resolution imaging, high dose efficiency and low system cost synergistically, our proposed CMCT system has great potentials in temporal bone imaging as well as various other clinical applications.
We previously demonstrated near-field speckle scanning based x-ray imaging to be an easy-to-implement phase sensing method capable of providing both high sensitivity and high resolution. Yet, this performance combination could only be achieved at the cost of a significant number of sample exposures and of extensive data acquisition time, thus tempering its implementation for tomography applications. Herein, we show ways of drastically lowering the number of exposures for the speckle scanning method to become attractive for computed tomography (CT) imaging. As the method presented can cope with…
Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer from artifacts and noise, since the phase retrieval and reconstruction are independent ("two-steps") without feedback from the original data. Our goal is to develop a method for material quantitative imaging based on a priori information specifically for the single-scanning data. Method: An iterative method that directly reconstructs the refractive index de…
Edge-Aligned Beam Placement in Scanning Probe Tomography via Reconstruction-Free Sequential Design of Experiments
Mathematics and Computer Science Division, Argonne National Laboratory, Lemont, IL, 60439, USA(阿贡国家实验室数学与计算机科学部);Computer Science Division, Argonne National Laboratory, Lemont, IL, 60439, USA(阿贡国家实验室计算机科学部)
Spatially or temporally resolved phase-based optoretinography with actively-tracked point-scanning optical coherence tomography
Medical Laser Center Lübeck GmbH(吕贝克医学激光中心有限公司);Institute of Biomedical Optics, University of Lübeck(吕贝克大学生物医学光学研究所);Heidelberg Engineering GmbH(海德堡工程有限公司);Airway Research Center North (ARCN), Member of the German Center for Lung Research (DZL)(北气道研究中心(ARCN),德国肺病研究中心(DZL)成员)
Forward-viewing endoscopic optical coherence tomography (OCT) provides 3D imaging in vivo, and can be combined with widefield fluorescence imaging by use of a double-clad fiber. However, it is technically challenging to build a high-performance miniaturized 2D scanning system with a large field-of-view. In this paper we demonstrate how a 1D scanning probe, which produces cross-sectional OCT images (B-scans) and 1D fluorescence T-scans, can be transformed into a 2D scanning probe by manual scanning along the second axis. OCT volumes are assembled from the B-scans using speckle decorrelation mea…
Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for developing countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The source and detector are translated in opposite directions for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In oth…
We demonstrate in vivo endoscopic optical coherence tomography (OCT) imaging in the forward direction using a flexible fiber bundle. In comparison to current conventional forward looking probe schemes, our approach simplifies the endoscope design by avoiding the integration of any beam steering components in the distal probe end due to 2D scanning of a focused light beam over the proximal fiber bundle surface. We describe the challenges that arise when OCT imaging with a fiber bundle is performed, such as multimoding or cross-coupling. The performance of different fiber bundles with varying pa…
The methodology for obtaining two- and three-dimensional magnetic resonance images by using azimuthally symmetric dipolar magnetic fields from ferromagnetic spheres is described. We utilize the symmetric property of a geometric sphere in the presence of a large externally applied magnetic field to demonstrate that a complete two- or three-dimensional structured rendering of a sample can be obtained without the motion of the sample relative to the sphere. Sequential positioning of the integrated sample-sphere system in an external magnetic field at various angular orientations provides all the …
The improvement of computed tomography (CT) image resolution is beneficial to the subsequent medical diagnosis, but it is usually limited by the scanning devices and great expense. Convolutional neural network (CNN)-based methods have achieved promising ability in super-resolution. However, existing methods mainly focus on the super-resolution of reconstructed image and do not fully explored the approach of super-resolution from projection-domain. In this paper, we studied the characteristic of projection and proposed a CNN-based super-resolution method to establish the mapping relationship of…
Confocal microscopy is the backbone of cellular research labs across the world but unfortunately, the imaging is restricted to a single plane. Chromatic confocal microscopy offers the possibility to image multiple planes simultaneously thus providing a manifold increase in the imaging speed whereas eliminating the need for z-axis scanning. Standard chromatic confocal systems have a limited imaging range of the order of a few hundreds of micrometers which limits their applications. In this work, using a single zinc selenide lens, we demonstrate a chromatic confocal tomography system that has an…
Computed Tomography (CT) takes X-ray measurements on the subjects to reconstruct tomographic images. As X-ray is radioactive, it is desirable to control the total amount of dose of X-ray for safety concerns. Therefore, we can only select a limited number of measurement angles and assign each of them limited amount of dose. Traditional methods such as compressed sensing usually randomly select the angles and equally distribute the allowed dose on them. In most CT reconstruction models, the emphasize is on designing effective image representations, while much less emphasize is on improving the s…
Optical tomographic imaging of biological specimen bases its reliability on the combination of both accurate experimental measures and advanced computational techniques. In general, due to high scattering and absorption in most of the tissues, multi view geometries are required to reduce diffuse halo and blurring in the reconstructions. Scanning processes are used to acquire the data but they inevitably introduces perturbation, negating the assumption of aligned measures. Here we propose an innovative, registration free, imaging protocol implemented to image a human tumor spheroid at mesoscopi…
PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measurement across devices. PARTICIPANTS: 55 Fovea-centered Spectral-Domain Optical Coherence Tomography volumes from eleven subjects were analyzed, obtained from Cirrus HD-OCT, RS-3000, Heidelberg Spectralis,…
National Digital Switching System Engineering and Technological Research Center(国家数字交换系统工程技术研究中心);Tsinghua University(清华大学);Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of Education(粒子与辐射成像教育部重点实验室(清华大学))
Limited angle problem is a challenging issue in x-ray computed tomography (CT) field. Iterative reconstruction methods that utilize the additional prior can suppress artifacts and improve image quality, but unfortunately require increased computation time. An interesting way is to restrain the artifacts in the images reconstructed from the practical filtered back projection (FBP) method. Frikel and Quinto have proved that the streak artifacts in FBP results could be characterized. It indicates that the artifacts created by FBP method have specific and similar characteristics in a stationary li…
AI-driven projection tomography with multicore fibre-optic cell rotation
Shanghai Artificial Intelligence Laboratory(上海人工智能实验室);TU Dresden(德累斯顿工业大学);Max Planck Institute for the Science of Light(马克斯·普朗克光科学研究所);Max Planck-Zentrum für Physik und Medizin(马克斯·普朗克物理与医学中心)
ACCELERATION: Sequentially-scanning DECT Imaging Using High Temporal Resolution Image Reconstruction And Temporal Extrapolation
Research Center for Medical Artificial Intelligence, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院医学人工智能研究中心);University of Chinese Academy of Sciences(中国科学院大学)
Sequential-Scanning Dual-Energy CT Imaging Using High Temporal Resolution Image Reconstruction and Error-Compensated Material Basis Image Generation
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);University of Chinese Academy of Sciences(中国科学院大学);Southeast University(东南大学);United Imaging Healthcare Company Ltd.(联影医疗科技股份有限公司)