arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2012.13528astro-ph.IM
收藏

对大型地面望远镜中热背景的物理理解

Towards a physical understanding of the thermal background in large ground-based telescopes

Leonard Burtscher, Ioannis Politopoulos, Sergio Fernández-Acosta, Tibor Agocs, Mario van den Ancker, Roy van Boekel, Bernhard Brandl, Hans Ulrich Käufl, Eric Pa… 展开作者

Leonard Burtscher, Ioannis Politopoulos, Sergio Fernández-Acosta, Tibor Agocs, Mario van den Ancker, Roy van Boekel, Bernhard Brandl, Hans Ulrich Käufl, Eric Pantin, Alex G. M. Pietrow, Ralf Siebenmorgen, Remko Stuik, Konrad R. W. Tristram, Willem-Jan de Wit

摘要:

地面热红外观测具有独特的科学潜力,但由于需要精确地减去高热背景,因此也极具挑战性。由于现有的斩波和点头技术需要进行修改,用于未来的中红外ELT成像仪和摄谱仪(METIS)的观测,我们调查了热背景扣除残差的来源。我们的目标是消除或至少减少点头的需要,以提高METIS的观察效率。为此,我们需要提高我们对斩波残差来源的认识,并设计观测方法,以最有效地去除它们,即以尽可能慢的点头频率。由于VLT/VISIR和GranTeCan/CanariCam的专门观测,我们已经成功地追踪了三种斩波残留物的起源:(1)入射窗,(2)蜘蛛和(3)瞳孔中的其他温暖发射体,特别是VLT M3镜细胞在其停车位置。我们的结论是,为了保持斩波残差在很长一段时间内稳定(因此允许较慢的点头周期),瞳孔照明需要保持恒定,即(成像)观察应在瞳孔稳定模式下进行,而不是场稳定模式,在后处理管道中进行图像去旋转。这现在被预见为所有METIS成像模式的默认观察概念。

英文摘要:

Ground-based thermal-infrared observations have a unique scientific potential, but are also extremely challenging due to the need to accurately subtract the high thermal background. Since the established techniques of chopping and nodding need to be modified for observations with the future mid-infrared ELT imager and spectrograph (METIS), we investigate the sources of thermal background subtraction residuals. Our aim is to either remove or at least minimise the need for nodding in order to increase the observing efficiency for METIS. To this end we need to improve our knowledge about the origin of chop residuals and devise observing methods to remove them most efficiently, i.e. with the slowest possible nodding frequency. Thanks to dedicated observations with VLT/VISIR and GranTeCan/CanariCam, we have successfully traced the origin of three kinds of chopping residuals to (1) the entrance window, (2) the spiders and (3) other warm emitters in the pupil, in particular the VLT M3 mirror cell in its parking position. We conclude that, in order to keep chopping residuals stable over a long time (and therefore allow for slower nodding cycles), the pupil illumination needs to be kept constant, i.e. (imaging) observations should be performed in pupil-stabilised, rather than field-stabilised mode, with image de-rotation in the post-processing pipeline. This is now foreseen as the default observing concept for all METIS imaging modes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑