用地面laser扫描仪测量绿岸望远镜主反射镜变形的方法的评价

Evaluating a strategy for measuring deformations of the primary reflector of the Green Bank telescope using a terrestrial laser scanner

Pedro Salas, Paul Marganian, Joe Brandt, Andrew Seymour, John Shelton, Nathan Sharp, Laura Jensen, Marty Bloss, Carla Beaudet, Dennis Egan, Nathaniel Sizemore, … 展开作者

Pedro Salas, Paul Marganian, Joe Brandt, Andrew Seymour, John Shelton, Nathan Sharp, Laura Jensen, Marty Bloss, Carla Beaudet, Dennis Egan, Nathaniel Sizemore, David T. Frayer, Frederic R. Schwab, Felix J. Lockman

摘要:

在分子丰富的3毫米窗口中使用大型反射天线进行天文观测,提供了独特的宇宙视图。为了有效地进行这些观测,必须校正重力和热变形。地面激光扫描仪已被用于测量由于重力引起的大型反射器天线的变形,但尚未用于测量热变形。在这项工作中,我们研究使用地面激光扫描仪测量的绿岸望远镜(GBT)的主反射器上的热变形。我们的方法涉及使用差分测量,以减少地面激光扫描仪的系统影响。我们使用GBT的主反射器的主动表面来验证我们的方法,并探讨其局限性。我们发现,当使用差分测量时,可以精确地测量对应于不同泽尼克多项式的变形,其幅度低至60 $μ$ m。当风速为$\lesssim2$ m s $^{-1}$时,已知变形的振幅与测得的振幅之间的差值为$<140~μ$ m。根据这些差异,我们估计应该有可能将GBT的表面误差降低到$240\pm6~μ$ m。这表明,使用商业现成的地面激光扫描仪,它是可能的测量变形引起的热梯度上的大型抛物面反射器。

英文摘要:

Astronomical observations in the molecule rich 3 mm window using large reflector antennas provide a unique view of the Universe. To efficiently carry out these observations gravitational and thermal deformations have to be corrected. Terrestrial laser scanners have been used to measure the deformations in large reflector antennas due to gravity, but have not yet been used for measuring thermal deformations. In this work we investigate the use of a terrestrial laser scanner to measure thermal deformations on the primary reflector of the Green Bank Telescope (GBT). Our method involves the use of differential measurements to reduce the systematic effects of the terrestrial laser scanner. We use the active surface of the primary reflector of the GBT to validate our method and explore its limitations. We find that when using differential measurements it is possible to accurately measure deformations corresponding to different Zernike polynomials down to an amplitude of 60 $μ$m. The difference between the amplitudes of known deformations and those measured are $<140~μ$m when the wind speed is $\lesssim2$ m s$^{-1}$. From these differences we estimate that it should be possible to bring the surface error of the GBT down to $240\pm6~μ$m. This suggests that using a commercial off-the-shelf terrestrial laser scanner it is possible to measure deformations induced by thermal gradients on a large parabolic reflector.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑