This paper reports on the time resolution of two photodetectors operated as single photon counters at high rate: a Hamamatsu R13742-103-M64 "conventional" (based on metal dynodes) multi-anode photomultiplier tube (MaPMT) and a Hamamatsu R10754-07-M16 microchannel plate photomultiplier tube (MCP-PMT). The MCP-PMT shows a time resolution (transit time spread, or jitter) of ~70 ps FWHM (~30 ps RMS) at low photon rates, but saturates above ~100 kHz/mm^2. The MaPMT can handle photon counting rates up to the highest tested, 10 MHz/mm^2. Its time resolution is ~250 ps FWHM (~110 ps RMS) when only the pixel center is illuminated, but pixel edge effects degrade the resolution to ~400 ps FWHM (~170 ps RMS) when the entire pixel area is illuminated.
The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE long-baseline neutrino experiment. In the DUNE dual-phase module, the liquid argon places high pressure on the photo-detectors located at the bottom of the 14-m cryostat. Four Hamamatsu R5912-02Mod PMTs were tested at 4-bar absolute pressure and cryogenic temperature (in liquid nitrogen) for the first time. No mechanical or electrical damage is reported, validating the…
We present a detailed characterisation of the new Hamamatsu R12199-01 HA MOD 3-inch photomultiplier tube (PMT) which is under consideration for the use in segmented optical modules of deep-ice neutrino detectors at the South Pole. Because of the significantly lower operation-temperature range compared to standard applications, a focus of our studies lies on the investigation of the temperature dependence of background characteristics (dark count rate, probability of correlated pulses), timing properties, gain and peak-to-valley ratio of this PMT type. In addition, the performance of the `HA co…
It is common practice to test the optical properties of photomultiplier tubes (PMTs) by illuminating the entire photocathode region from the front at once and measuring the average performance. However, for optimal utilisation of the PMT performance in experiments, especially in the single-photon region, it is essential to also know the systematic variations across the photocathode, which requires measurements with focused light sources that illuminate only small regions of the PMT. We present a detailed uniformity characterisation of the gain, transit time, transit time spread, and pulse shap…
The measurement of late-pulses and after-pulses in the large area Hamamatsu R7081 photomultiplier with improved quantum-efficiency photocathode
INFN - Sezione di Catania(意大利国家核物理研究所卡塔尼亚分部);Dipartimento di Fisica dell’Università e INFN- Via Dodecaneso 33, 16146 Genova,Italy(热那亚大学物理系及意大利国家核物理研究所);Moscow State University(莫斯科国立大学)
Current and future neutrino and direct detection dark matter experiments hope to take advantage of improving technologies in photon detection. Many of these detectors are large, monolithic optical detectors that use relatively low-cost, large-area, and efficient photomultiplier tubes (PMTs). A candidate PMT for future experiments is a newly developed prototype Hamamatsu PMT, the R5912-MOD. In this paper we describe measurements made of the single photoelectron time and charge response of the R5912-MOD, as well as detail some direct comparisons to similar PMTs. Additionally, a 1D scan of the ph…
Measurement of the absolute Quantum Efficiency of Hamamatsu model R11410-10 photomultiplier tubes at low temperatures down to liquid xenon boiling point
The model R5912-20MOD photomultiplier tube(PMT) is made for cryogenic application by Hamamatsu. In this paper, we report on the measurement of relative quantum efficiency (QE) of this model PMT at liquid argon(LAr) temperature. Furthermore, a specially designed setup and relevant test method are introduced. The relative QE is measured in visible wavelengths with the PMT emerged in high purity nitrogen atmosphere. The results show that the change of QE at LAr temperature is within about 5% compared with room temperature around 420 nm. However, the QE increases about 10% in the shorter wavelengt…
Statistical analysis and correction of the pile-up effect in MAPMT single photoelectron counting with the SPACIROC-3 ASIC: application to the Mini-EUSO experiment
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed durin…
We describe an improved in-situ calibration of the single-photoelectron charge distributions for each of the in-ice Hamamatsu Photonics R7081-02[MOD] photomultiplier tubes in the IceCube Neutrino Observatory. The characterization of the individual PMT charge distributions is important for PMT calibration, data and Monte Carlo simulation agreement, and understanding the effect of hardware differences within the detector. We discuss the single photoelectron identification procedure and how we extract the single-photoelectron charge distribution using a deconvolution of the multiple-photoelectron…
JUNO is a 20-kton liquid scintillator detector aiming to determine the neutrino mass ordering, precisely measure the oscillation parameters, detect the astrophysical neutrinos and search for exotic physics. It is designed to reach an energy resolution of 3% at 1 MeV with the highest ever PMT coverage, using two types of 20 inch phototubes: MCP-PMT from NNVT and dynode-PMT from Hamamatsu. In this article, the gain and charge response of the MCP and dynode PMTs are investigated with the study of JUNO Central Detector prototype. The linearity of the MCP-PMT charge output is measured too to check …
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial depe…
We present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel's properties such…
The neutrino detector of the Jiangmen Underground Neutrino Observatory (JUNO) is designed to use 20 kilotons of liquid scintillator and approximately 16,000 20-inch photomultipliers (PMTs).One of the options is to use the 20-inch R12860 PMT with high quantum efficiency which has recently been developed by Hamamatsu Photonics. The performance of the newly developed PMT preproduction samples is evaluated. The results show that its quantum efficiency is $30\%$ at $400 nm$. Its Peak/Valley (P/V) ratio for the single photoelectron is 4.75 and the dark count rate is $27 kHz$ at the threshold of 3 mV…
The RICH detectors of the LHCb experiment provide identification of hadrons produced in high energy proton-proton collisions in the LHC at CERN over a wide momentum range (2 to 100 GeV/c). Cherenkov light is collected on photon detector planes sensitive to single photons. The RICH will be upgraded (in 2019) to read out every bunch crossing, at a rate of 40 MHz. The current hybrid photon detectors (HPD) will be replaced with multi-anode photomultiplier tubes (customisations of the Hamamatsu R11265 and the H12699 MaPMTs). These 8$\times$8 pixel devices meet the experimental requirements thanks t…
Development and characterization of hybrid MCP-PMT with embedded Timepix4 ASIC used as pixelated anode
INFN, Division of Ferrara(意大利国家核物理研究所费拉拉分部);Dept. of Physics and Earth Science, University of Ferrara(费拉拉大学地球科学与物理学系);EP Department, CERN(欧洲核子研究中心实验物理部)
University of California, Santa Barbara(加州大学圣塔芭芭拉分校);Korea University(高丽大学);CERN(欧洲核子研究组织);New York University(纽约大学);The Ohio State University(俄亥俄州立大学);Lebanese University(黎巴嫩大学)
To increase the light yield of a liquid Ar (LAr) detector, we optimized the evaporation technique of tetraphenyl butadiene (TPB) on the detector surface and tested the operability of a silicon photomultiplier (SiPM), namely, the multi-pixel photon counter with through-silicon-via (TSV-MPPC, Hamamatsu Photonics K.K.) at LAr temperature. TPB converts the LAr scintillations (vacuum ultraviolet light) to visible light, which can be detected by high-sensitivity photosensors. Because the light yield depends on the deposition mass of TPB on the inner surface of the detector, we constructed a well-con…
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow γA'$, where the $A'$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF$_2$ cryst…
Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over traditional PMT. In this paper, we developed a single-phase liquid argon detector using eight 1 $\times$1 inch$^2$ Hamamatsu S14161-6050HS 4$\times$4 SiPM arrays. The directly measured light yield is 25.7 $\pm$ 1.6 photo-electrons per keV, which corresponds to 12.8 $\pm$ 0.8 photo-electrons primarily generated by the argon scintillation. The rest is contributed…
The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice for the XENON1T dual-phase time projection chamber. The device has been optimized for a very low intrinsic radioactivity, a high quantum efficiency and a high sensitivity to single photon detection. A total of 248 tubes are currently operated in XENON1T, selected out of 321 tested units. In this article the procedures implemented to evaluate the large number of tubes prior to their installation in XENON1T are described. The parameter distributions for all tested tubes are shown, with an emphasis on those selected for X…