An Ultra-Low Background PMT for Liquid Xenon Detectors

D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Coffey,… 展开作者

D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Coffey, L. deViveiros, M. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm, R. G. Jacobsen, L. Kastens, K. Kazkaz, N. Larsen, C. Lee, K. Lesko, A. Lindote, M. I. Lopes, A. Lyashenko, D. C. Malling, R. Mannino, D. McKinsey, D. Mei, J. Mock, M. Morii, H. Nelson, F. Neves, J. A. Nikkel, M. Pangilinan, K. Pech, P. Phelps, T. Shutt, C. Silva, W. Skulski, V. N. Solovov, P. Sorensen, J. Spaans, T. Stiegler, M. Sweany, M. Szydagis, D. Taylor, J. Thomson, M. Tripathi, S. Uvarov, J. R. Verbus, N. Walsh, R. Webb, J. T. White, M. Wlasenko, F. L. H. Wolfs, M. Woods, C. Zhang

摘要:

本文介绍了两种型号的光电倍增管的放射性筛选结果,这种光电倍增管是为当前和未来的液体氙实验而设计的。在LUX暗物质实验中使用的滨松5.6厘米直径R8778光电倍增管,对四种常见的放射性同位素:铀238、钍232、钾40和钴60都产生了阳性检测。LUX材料的筛选使其他探测器材料的背景低于R8778的贡献。还筛选了直径为7.6 cm的原型滨松R11410 MOD PMT,其基准同位素计数测量值为<0.4 238 U/ <0.3 232 Th/ <8.3 40 K/ 2.0+-0.2 60 Co mBq/PMT。这表示在R8778和R11410 MOD之间,光电阴极表面积(4.5 cm至6.4 cm直径)加倍的同时,光电阴极表面积大幅减少,相当于每PMT的\times 1/24 238 U/ \times 1/9 232 Th/ \times 1/8 40 K的变化。PMT之间的60 Co测量值相当,但通过进一步选择材料,可以在未来的R11410 MOD装置中显著降低。假设PMT活性等于测得的90%上限,Monte Carlo估计表明,在进一步选择60 Co还原材料后,用R11410 MOD PMT替换R8778 PMT将使LUX PMT电子反冲背景贡献改变\times 1/25倍,核反冲背景改变\times 1/36倍。在测量的R8778水平以下的背景中的强烈减少使得R11410 MOD在大规模液体氙探测器中的使用成为非常有竞争力的技术。

英文摘要:

Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑