arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2107.07798physics.ins-det
收藏

大型单相液氙暗物质探测器的电极设计

On the Electrode Configurations in a Large Single Phase Liquid Xenon Detector for Dark Matter Searches

P. Juyal, K. L. Giboni, X. Ji, J. Liu

摘要:

在不久的将来,将要求在50吨范围内为暗物质的搜索提供非常大的液体氙(氙)探测器。为了避免双相位检测器的不切实际的长的单个漂移空间,使用单相技术似乎是有益的。由于电子可以在任何方向上漂移,我们可以分割均匀介质,从而避免4 m级的过度最大漂移路径。较短的检测器长度具有若干益处,例如,对于相同的漂移场需要较低的阴极电压。我们可以很容易地将TPC分成两个区域,阴极在中心,两个阳极在顶部和底部。还可以使用在相同的液体体积中彼此堆叠的多个TPC,以进一步减小最大漂移长度。通过在中心安装额外的阳极来进一步划分漂移空间将需要S2光子穿过液体,其长度是仅为30 - 40 cm的Lion中的瑞利散射长度的几倍。这对于良好的x - y定位来说似乎是过度的。因此,我们提出了一个几何的两个独立的TPC与两个漂移空间。尽管有早期的出版物,但人们仍然对阴影的影响感到担忧。阳极区域的详细FEM模型示出,在对准的导线布置的情况下,漂移电子在宽度为15 $^{\circ}$ - 20 $^{\circ}$的窄角度范围内侧向撞击在阳极上。大多数S2光子在附近PMT阵列的全视图中发射。大约37%的S2光子被阳极线遮蔽,其中30%将再次反射回金属丝的镀金层。因此,我们可以观察到总S2光的74%。然而,与双相检测器相比,我们不会受到提取效率的影响,有时报告低至50%。

英文摘要:

In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to use the single-phase technique. Since electrons then can drift in any direction, we can segment the homogeneous medium and thus avoid an excessive maximum drift path of order 4 m. The shorter detector length has several benefits, e.g. requiring a lower cathode voltage for the same drift field. We can easily split the TPC into two regions with the cathode in the center and two anodes at the top and bottom. One also can use multiple TPCs stacked on top of each other in the same liquid volume to reduce the maximum drift length even further. A further division of the drift space by installing an additional anode in the center would require S2 photons to traverse the liquid for several times the Rayleigh scattering length in LXe, which is only 30 - 40 cm. This seems to be excessive for good x - y localization. We therefore suggest a geometry of two independent TPCs with two drift spaces each. Despite earlier publications concerns persisted about the effect of shadowing. A detailed FEM model of the anode regions shows that with an aligned wire arrangement the drifting electrons impinge sideways on the anode in a narrow angular range of width 15$^{\circ}$ - 20$^{\circ}$. Most S2 photons are emitted in full view of the close-by PMT array. About 37% of the S2 photons are shadowed by the anode wire out of which 30\% will be reflected back again on the gold plating of the wires. Thus we can observe 74% of the total S2 light. Compared to a dual-phase detector, however, we do not suffer from the extraction efficiency, sometimes reported as low as 50%.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑