Development and characterization of hybrid MCP-PMT with embedded Timepix4 ASIC used as pixelated anode
INFN, Division of Ferrara(意大利国家核物理研究所费拉拉分部);Dept. of Physics and Earth Science, University of Ferrara(费拉拉大学地球科学与物理学系);EP Department, CERN(欧洲核子研究中心实验物理部)
Riccardo Bolzonella, Jerome Alozy, Rafael Ballabriga, Nicolò Vladi Biesuz, Michael Campbell, Viola Cavallini, Angelo Cotta Ramusino, Massimiliano Fiorini, Edoar… 展开作者
Riccardo Bolzonella, Jerome Alozy, Rafael Ballabriga, Nicolò Vladi Biesuz, Michael Campbell, Viola Cavallini, Angelo Cotta Ramusino, Massimiliano Fiorini, Edoardo Franzoso, Marco Guarise, Xavi Llopart Cudie, Gabriele Romolini, Alessandro Saputi
发表信息:
Nuclear Instruments and Methods in Physics Research Section A, Volume 1082, Part 1, February 2026, 170965
We present a novel single-photon detector based on a vacuum tube incorporating a photocathode, a microchannel plate (MCP), and a Timepix4 CMOS ASIC functioning as a pixelated anode. Designed to handle photon rates up to 1 billion per second across a 7 cm$^2$ active area, the detector achieves outstanding spatial and temporal resolutions of 5-10 $μ$m and below 50 ps r.m.s., respectively.
The Timepix4 ASIC comprises approximately 230,000 pixels, each integrating analog and digital front-end electronics. This enables data-driven acquisition and supports data transmission rates up to 160 Gb/s. External FPGA-based electronics manage both configuration and readout.
In order to test the timing performance of the Timepix4 ASIC we performed preliminary characterization of an assembly bonded to a 100 $μ$m thick n-on-p silicon sensor using a pulsed infrared laser, which demonstrated a per-pixel timing resolution of 110 ps, with cluster-based averaging methods improving to below 50 ps.
Six prototype detectors incorporating different MCP stack configurations and end-spoiling depths were produced by Hamamatsu Photonics. We report on their characterization, including dark count rates, gain, and spatial and timing resolutions, assessed both in laboratory conditions and during a test-beam campaign at CERN's SPS facility.
A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods
3D Particle Track Reconstrution in a Single Layer Cadmium-Telluride Hybrid Active Pixel Detector
在过去的20年里,对无中微子双β衰变的研究推动了各种探测器技术的发展。该领域的一个新分支是高度像素化的半导体探测器-例如CdTe-Timepix探测器。它包括一个14 mm x 14 mm x 1 mm尺寸的碲化镉传感器和一个ASIC,该ASIC具有55 \textmu m像素间距的256 x 256像素,可用于获得每个像素的光谱或定时信息。在常规操作中,它可以提供粒子轨道的二维投影;然而,三维轨道对于无中微子双β衰变和其他应用是理想的。在本文中,我们提出了一种方法来获得这样的轨迹。该方法的开发和测试模拟,假设一些微小的修改Timepix ASIC。此外,我们能够测试的方法实验,并在最好的情况下实现了约90 \textmu m的位置分辨率与电子的4.4 GeV。
Study on Timing Performance of a Readout Circuit for SiPM
近年来,SiPM光电器件在基于飞行时间的正电子发射断层成像(TOF-PET)领域引起了广泛关注。利用它们构造具有良好符合时间分辨率(CTR)的PET探测器一直是研究的热点之一。本文设计了一种基于共基极电流放大器结构的SiPM读出前置放大器,并在前置放大器的基础上引入了零极点(PZ)补偿网络,研究了影响PET探测器时序性能的主要因素。通过实验测量,我们发现CTR与放大器带宽、SiPM偏置电压、比较器阈值以及PZ网络参数有很大关系。测试装置有两个检测器,一个带有与Hamamatsu SiPM(S12642-0404)耦合的LYSO晶体(3 mm 3 mm 10 mm),另一个带有与PMT-R9800耦合的LaBr 3。通过对读出电路的优化设计,得到了两个探测器之间的CTR为266 ps的半高宽。测试结果为下一步读出ASIC芯片的设计提供了指导。
An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation
基于硅光电倍增器(SiPMs)的PET扫描器已经被广泛用作先进的核医学成像技术,其产生局部体内生物学和生物化学的定量图像。SiPM的紧凑尺寸允许闪烁晶体和光电传感器之间的直接一对一耦合,从而产生比必须在光电倍增管(PMT)PET系统中使用的光共享方法更好的定时和能量分辨率。为了减小读出电子设备的体积,具有位置解码器的前端多路复用器是没有高度集成的专用集成电路(ASIC)的一对一系统的常见选择。然而,在这种情况下,我们不能测量每个晶体的沉积能量激发的湮灭光子,所以晶间散射(ICS)事件将导致晶体错位,然后恶化探测器的固有分辨率。此外,考虑到SiPM的增益色散和非线性输出导致的能量窗口内的事件拒绝,需要能量校正机制。然而,缺乏每个晶体的能量信息将引入大的能量校正误差的ICS事件。针对这一问题,本文提出了一种在Kintext-7现场可编程门阵列(FPGA)器件上实现的在线能量校正机制。实验室中的实验使用8 X 8分段LYSO晶体与8 X 8 SiPM(J系列,来自ON Semiconductor)阵列耦合进行,该阵列在22 Na点源激发下。测试结果表明,非ICS和ICS事件的能量都可以精确校正,能量分辨率优于12%。我们还将此方法应用于实际的临床PET扫描仪下的68 Ge线源,以验证其多通道的可靠性。