Exotic quantum phenomena have been demonstrated in recently discovered intrinsic magnetic topological insulator MnBi2Te4. At its two-dimensional limit, quantum anomalous Hall (QAH) effect and axion insulator state are observed in odd and even layers of MnBi2Te4, respectively. The measured band structures exhibit intriguing and complex properties. Here we employ low-temperature scanning tunneling microscopy to study its surface states and magnetic response. The quasiparticle interference patterns indicate that the electronic structures on the topmost layer of MnBi2Te4 is different from that of the expected out-of-plane A-type antiferromagnetic phase. The topological surface states may be embedded in deeper layers beneath the topmost surface. Such novel electronic structure presumably related to the modification of crystalline structure during sample cleaving and re-orientation of magnetic moment of Mn atoms near the surface. Mn dopants substituted at the Bi site on the second atomic layer are observed. The ratio of Mn/Bi substitutions is 5%. The electronic structures are fluctuating at atomic scale on the surface, which can affect the magnetism of MnBi2Te4. Our findings shed new lights on the magnetic property of MnBi2Te4 and thus the design of magnetic topological insulators.
A simple, reliable method for preparation of bulk Cr tips for Scanning Tunneling Microscopy (STM) is proposed and its potentialities in performing high-quality and high-resolution STM and Spin Polarized-STM (SP-STM) are investigated. Cr tips show atomic resolution on ordered surfaces. Contrary to what happens with conventional W tips, rest atoms of the Si(111)-7x7 reconstruction can be routinely observed, probably due to a different electronic structure of the tip apex. SP-STM measurements of the Cr(001) surface showing magnetic contrast are reported. Our results reveal that the peculiar prope…
We have used a low-temperature scanning tunneling microscope (STM) to study the surface of heavily doped semiconductor InAs crystals. The crystals are cleaved in situ along the (110) plane. Apart from atomically flat areas, we also observe two major types of atomic scale defects which can be identified as S dopant atoms and as As vacancies, respectively. The strong bias voltage dependence of the STM image of the impurities can be explained in terms of resonant tunneling through localized states which are present near the impurity.
Sample thickness is an important parameter in transmission electron microscopy (TEM) imaging, for interpreting image contrast and understanding the relationship between properties and microstructure. In this study, we introduce a method for determining thickness in scanning transmission electron microscopy (STEM) mode based on scanning moiré fringe (SMF). Sample thickness can be determined in situ in the medium magnification using focal-series SMF imaging, with beam damage and contamination avoided to a large extent. This method provides a fast and convenient way for determining thickness in T…
Electronic conduction pathways in dielectric thin films are explored using automated experiments in scanning probe microscopy (SPM). Here, we use large field of view scanning to identify the position of localized conductive spots and develop a SPM workflow to probe their dynamic behavior at higher spatial resolution as a function of time, voltage, and scanning process in an automated fashion. Using this approach, we observe the variable behaviors of the conductive spots in a 20 nm thick ferroelectric Hf0.54Zr0.48O2 film, where conductive spots disappear and reappear during continuous scanning.…
Electronic transport in semiconducting single-wall carbon nanotubes is studied by combined scanning gate microscopy and scanning impedance microscopy (SIM). Depending on the probe potential, SIM can be performed in both invasive and non-invasive mode. High-resolution imaging of the defects is achieved when the probe acts as a local gate and simultaneously an electrostatic probe of local potential. A class of weak defects becomes observable even if they are located in the vicinity of strong defects. The imaging mechanism of tip-gating scanning impedance microscopy is discussed.
Ultraviolet and visible radiation is observed from the contacts of a scanning tunneling microscope with Si(100) and (111) wafers. This luminescence relies on the presence of hot electrons in silicon, which are supplied, at positive bias on n- and p-type samples, through the injection from the tip, or, at negative bias on p-samples, by Zener tunneling. Measured spectra reveal a contribution of direct optical transitions in Si bulk. The necessary holes well below the valence band edge are injected from the tip or generated by Auger processes.
We have performed the most realistic simulation to date of the operation of a scanning tunneling microscope. Probe-sample distances from beyond tunneling to actual surface contact are covered. We simultaneously calculate forces, atomic displacements, and tunneling currents, allowing quantitative comparison with experimental values. A distance regime below which the probe becomes unstable is identified. It is shown that the real distance differs substantially from previous estimates because of large atomic displacements on the surface and at the probe-tip.
Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe microscopy, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.
The scanning mid-IR-laser microscopy was previously demonstrated as an effective tool for characterization of different semiconductor crystals. Now the technique has been successfully applied for the investigation of CZ Si$_x$Ge$_{1-x}$---a promising material for photovoltaics---and multicrystalline silicon for solar cells.
We have performed scanning capacitance microscopy using a relaxation oscillator. Precision calibrations indicate a sensitivity on the order of 0.05 pF. Surface topography of metallic structures, such as machined grooves and coins, can be readily obtained either in the constant-height (non-contact) or tapping (contact) mode. Spatial resolution of sub-50 $μ$m has been achieved.
We report a novel atom extraction mechanism from the native substrate by means of a scanning tunneling microscope tip-crash on a Ag(111) surface at 5 K. Individual atoms are scattered on the surface when a silver coated tip is dipped into the substrate at low tunneling biases. Quantitative analyses reveal that the mechanical energy supplied by the tip-crash dominates the atom extraction process. Application of this procedure is demonstrated by constructing quantum structures using the extracted atoms on an atom-by-atom basis.
Cesium adsorption structures on Ag(111) were characterized in a low-temperature scanning tunneling microscopy experiment. At low coverages, atomic resolution of individual Cs atoms is occasionally suppressed in regions of an otherwise hexagonally ordered adsorbate film on terraces. Close to step edges Cs atoms appear as elongated protrusions along the step edge direction. At higher coverages, Cs superstructures with atomically resolved hexagonal lattices are observed. Kinetic Monte Carlo simulations model the observed adsorbate structures on a qualitative level.
We present numerical simulations of scattering-type Scanning Near-Field Optical Microscopy (s-SNOM) of 1D plasmonic graphene junctions. A comprehensive analysis of simulated s-SNOM spectra is performed for three types of junctions. We find conditions when the conventional interpretation of the plasmon reflection coefficients from s-SNOM measurements does not apply. Our results are applicable to other conducting 2D materials and provide a comprehensive understanding of the s-SNOM techniques for probing local transport properties of 2D materials.
The graphene moire structures on metals, as they demonstrate both long (moire) and short (atomic) scale ordered structures, are the ideal systems for the application of scanning probe methods. Here we present the complex studies of the graphene/Ir(111) system by means of 3D scanning tunnelling and atomic force microscopy/spectroscopy as well as Kelvin-probe force microscopy. All results clearly demonstrate a variation of the moire and atomic scale contrasts as a function of the bias voltage as well as the distance between the scanning probe and the sample, allowing to discriminate between topo…
Atomically resolved images of monolayer organic crystals have only been obtained with scanning probe methods so far. On the one hand, they are usually prepared on surfaces of bulk materials, which are not accessible by (scanning) transmission electron microscopy. On the other hand, the critical electron dose of a monolayer organic crystal is orders of magnitudes lower than the one for bulk crystals, making (scanning) transmission electron microscopy characterization very challenging. In this work we present an atomically resolved study on the dynamics of a monolayer CuPcCl\textsubscript{16} cr…
The reconstruction on Ge(001) surface is locally and reversibly changed between c(4x2) and p(2x2) by controlling the bias voltage of a scanning tunneling microscope (STM) at 80K. It is c(4x2) with the sample bias voltage V_b =< -0.7V. This structure can be kept with V_b =< 0.6V. When V_b is higher than 0.8V during the scanning, the structure changes to p(2x2). This structure is then maintained with V_b >= - 0.6V. The observed local change of the reconstruction with hysteresis is ascribed to inelastic scattering during the electron tunneling in the electric field under the STM-tip.
We describe the near-field microwave microscopy of microwave devices on a length scale much smaller than the wavelength used for imaging. Our microscope can be operated in two possible configurations, allowing a quantitative study of either material properties or local electric fields.
Thin films of La0.7Sr0.3MnO3 on MgO show a metal insulator transition and colossal magnetoresistance. The shape of this transition can be explained by intrinsic spatial inhomogeneities, which give rise to a domain structure of conducting and insulating domains at the submicrometer scale. These domains then undergo a percolation transition. The tunneling conductance and tunneling gap measured by scanning tunneling spectroscopy were used to distinguish and visualize these domains.
We have investigated the growth of antiferromagnetic Mn3N2(001) on MgO (001) by molecular beam epitaxy and scanning tunneling microscopy . The images show smooth terraces and atomic steps. On some of the terraces a unique and new reconstruction is seen, resolved as square Mn tetramers in a c(4x2) structural arrangement. Two domains of the tetramer reconstruction, rotated by 90$^\circ$ to each other, occur. A model is presented for this square Mn tetramer reconstruction, in which the Mn atoms of the tetramer layer belong to the Mn layer at the surface in the MnN-MnN-Mn stacking sequence.
The thermal properties of amorphous and crystalline phases in chalcogenide phase change materials (PCM) play a key role in device performance for non-volatile random-access memory. Here, we report the nanothermal morphology of amorphous and crystalline phases in laser pulsed GeTe and Ge2Sb2Te5 thin films by scanning thermal microscopy (SThM). By performing SThM measurements and applying quantitative physical models to two film thicknesses, the PCM thermal conductivities and thermal boundary conductances between the PCM and SThM probe are independently estimated for the amorphous and crystallin…
In this study, we have used a Zr-Nb alloy containing well-defined nano-precipitates as a model material in which to study imaging contrast inversions (atomic number or diffraction contrast) observed with the forescattered electron imaging system, ARGUSTM, in a scanning electron microscope (SEM) when imaging a thin foil in a transmission geometry. The study is based on Monte Carlo simulations and analysis of micrographs experimentally acquired under different imaging conditions. Based on the results, imaging conditions that enhance atomic number or diffraction contrast have been proposed. Data …
Nanoscale lithography on SrRuO3 (SRO) thin film surfaces has been performed by scanning tunneling microscopy under ambient conditions. The depth of etched lines increases with increasing bias voltage but it does not change significantly by increasing the tunneling current. The dependence of line width on bias voltage from experimental data is in agreement with theoretical calculation based on field-induced evaporation. Moreover, a three-square nanostructure was successfully created, showing the capability of fabricating nanodevices in SRO thin films.
We use a near-field scanning microwave microscope to simultaneously image the dielectric constant, loss tangent, and topography in a PbTiO_3 crystal. By this method, we study the effects of the local dielectric constant and loss tangent in the geometry of periodic domains on the measured resonant frequency, and quality factor. We also carry out theoretical calculations and the results agree well with the experimental data and reveal the anisotropic nature of dielectric constant.
Scanning tunneling microscopy images of hydrogen-terminated Si(110) surfaces are studied using first-principles calculations. Our results show that the calculated filled-state images and local density of states are consistent with recent experimental results, and the empty-state images appear significantly different from the filled-state ones. To elucidate the origin of this difference, we examined in detail the local density of states, which affects the images, and found that the bonding and antibonding states of surface silicon atoms largely affect the difference between the filled- and empt…
We present a theory and a simulation of thermal diffuse scattering due to the excitation of magnons in scanning transmission electron microscopy. The calculations indicate that magnons can present atomic contrast when detected by electron energy-loss spectroscopy using atomic-size electron beams. The results presented here indicate that the intensity of the magnon diffuse scattering in bcc iron at 300~K is 4 orders of magnitude weaker than the intensity of thermal diffuse scattering arising from atomic vibrations. In an energy range where the phonon and magnon dispersions do not overlap, a mon…
X-ray photoelectron spectroscopy and diffraction (XPS, XPD) and scanning tunneling microscopy (STM) have been used for study of NbOx-structures on the Nb(110) surface. It is shown that niobium atoms are ordered to form a two-dimensional superstructure with equidistant spacing between the chains of niobium atoms. Chemical shifts of Nb3d- and O1s-levels demonstrate that the oxide layer corresponds to niobium monoxide NbO and the most part of oxygen in chemisorbed state is localized on the surface. A model of quasi-ordered structure of NbO on the Nb(110) surface is proposed.
Spatially resolved photocurrent measurements on carbon nanotube field-effect transistors (CNFETs) operated in various transport regimes are reported. It is demonstrated that the photocurrents measured at different biasing conditions provide access to the electronic band structure profile of the nanotube channel. A comparison of the profiles with the device switched into n- or p-type states clearly evidences the impact of chemical doping from the ambient. Moreover, we show that scanning photocurrent microscopy constitutes an effective and facile technique for the quantitative determination of t…
We report on the first principles determination of the conductance properties of Buckminster fullerene adsorbed on a gold surface, comparing them with recent Scanning Tunneling Microscopy/Spectroscopy (STM/S) experiments [J.Chem.Phys.116, 832 (2002)]. Our procedure has the two appealing features of being able to elucidate delicate aspects of STM/S results without resorting to ad hoc fittings or approximations and to provide a complete description of the phenomena involved when the tip approaches the adsorbate.
Electron-electron interactions and excitons in carbon nanotubes are locally measured by combining Scanning tunneling spectroscopy and optical absorption in bundles of nanotubes. The largest gap deduced from measurements at the top of the bundle is found to be related to the intrinsic quasi-particle gap. From the difference with optical transitions, we deduced exciton binding energies of 0.4 eV for the gap and 0.7 eV for the second Van Hove singularity. This provides the first experimental evidence of substrate-induced gap renormalization on SWNTs.
As a consequence of elasticity, mechanical deformations of crystals occur on a length scale comparable to their thickness. This is exemplified by applying a homogeneous electric field to a multi-domain ferroelectric crystal: as one domain is expanding the adjacent ones are contracting, leading to clamping at the domain boundaries. The piezomechanically driven surface corrugation of micron-sized domain patterns in thick crystals using large-area top electrodes is thus drastically suppressed, barely accessible by means of piezoresponse force microscopy.
We predict the occurrence of metastable skyrmionic spin structures such as antiskyrmions and higher-order skyrmions in ultra-thin transition-metal films at surfaces using Monte Carlo simulations based on a spin Hamiltonian parametrized from density functional theory calculations. We show that such spin structures will appear with a similar contrast in spin-polarized scanning tunneling microscopy (SP-STM) images. Both skyrmions and antiskyrmions display a circular shape for out-of-plane magnetized tips and a two-lobe butterfly contrast for in-plane tips. An unambiguous distinction can be achiev…
We show scanning probe microscopy measurements of metallic nanocontacts between controlled electromigration cycles. The nanowires used for the thinning process are fabricated by shadow evaporation. The highest resolution obtained using scanning force microscopy is about 3 nm. During the first few electromigration cycles the overall slit structure of the nanocontact is formed. The slit first passes along grain boundaries and then at a later stage vertically splits grains in the course of consuming them. We find that first the whole wire is heated and later during the thinning process as the sli…
The work describes the capabilities of Laser Scanning Microscopy (LSM) as a spatially resolved method of testing high_Tc materials and devices. The earlier results obtained by the authors are briefly reviewed. Some novel applications of the LSM are illustrated, including imaging the HTS responses in rf mode, probing the superconducting properties of HTS single crystals, development of twobeam laser scanning microscopy. The existence of the phase slip lines mechanism of resistivity in HTS materials is proven by LSM imaging.
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. We present a new algorithm named PRISM that combines features of the two most commonly used algorithms, the Bloch wave and multislice methods. PRISM uses a Fourier interpolation factor $f$ that has typical values of 4-20 for atomic resolution simulations. We show that in many cases PRISM can provide a speedup that scales with $f^4$ compared to multislice simulations, with a negligible loss of acc…
We demonstrate rotational excitation spectroscopy with the scanning tunneling microscope for physisorbed hydrogen and its isotopes hydrogen-deuterid and deuterium. The observed excitation energies are very close to the gas phase values and show the expected scaling with moment of inertia. Since these energies are characteristic for the molecular nuclear spin states we are able to identify the para and ortho species of hydrogen and deuterium, respectively. We thereby demonstrate nuclear spin sensitivity with unprecedented spatial resolution.
PICTS: A Novel Deep Reinforcement Learning Approach for Dynamic P-I Control in Scanning Probe Microscopy
National University of Singapore(新加坡国立大学);Institute of Materials Research and Engineering, Agencies of Science, Technology and Research (A*STAR)(新加坡科技研究局材料研究与工程研究所);NUS Research Institute (NUSRI)(新加坡国立大学研究院)
Nickel islands are grown on W(110) at elevated temperatures. Islands with a thickness of two layers are investigated with scanning tunneling microscopy. Spectroscopic measurements reveal that nanometer sized areas of the islands exhibit distinctly different apparent heights and dI/dV spectra. Spin polarized and paramagnetic band structure calculations indicate that the spectral features are due to fcc(111) and bcc(110) orientations of the Ni film, respectively.
Complex oxide interfaces have been one of the central focuses in condensed matter physics and material science. Over the past decade, aberration corrected scanning transmission electron microscopy and spectroscopy has proven to be invaluable to visualize and understand the emerging quantum phenomena at an interface. In this paper, we briefly review some recent progress in the utilization of electron microscopy to probe interfaces. Specifically, we discuss several important challenges for electron microscopy to advance our understanding on interface phenomena, from the perspective of variable t…
The scanning mid-IR-laser microscopy was previously demonstrated as an effective tool for characterization of different semiconductor crystals. Now the technique has been successfully applied for the investigation of CZ SixGe1-x -- a promising material for photovoltaics - and multicrystalline silicon for solar cells. In addition, this technique was shown to be appropriate for imaging of polishing-induced defects as well as such huge defects as "pin holes". Besides, previously unexplained "anomalous" (cubic power) dependence of signal of the scanning mid-IR-laser microscope in the optical-beam-…
Here a new microscopic method is proposed to image and characterize very thin samples like few-layer materials, organic molecules, and nanostructures with nanometer or sub-nanometer resolution using electron beams of energies lower than 20 eV. The microscopic technique achieves high resolution through the proximity (or near-field) effect, as in scanning tunneling microscopy (STM), while it also allows detection of transmitted electrons for imaging and spectroscopy, as in scanning transmission electron microscopy (STEM). This proximity transmission electron microscopy (PSTEM) does not require a…
The conductance-voltage spectrum of molecular nanostructures measured by scanning tunneling spectroscopy (STS) is generally assumed to reflect the local density of states of the molecule. This excludes the possibility of observing negative differential resistance (NDR). We report here the observation of NDR in the scanning tunneling microscope (STM) current-voltage (I-V) characteristics of self-assembled monolayer (SAM) of 4-p-Terphenylthiol molecules on gold substrate measured using a platinum probe. We argue that the NDR arises from narrow structures in the local density of states at the tip…
The effect of hydrogenation on the topography and the electronic properties of graphene and graphite surfaces are studied by scanning tunneling microscopy and spectroscopy. The surfaces are chemically modified using Ar/H2 plasma. Analyzing thousands of scanning tunneling spectroscopy measurements we determine that the hydrogen chemisorption on the surface of graphite/graphene opens on average an energy band gap of 0.4 eV around the Fermi level. We find that although the plasma treatment modifies the surface topography in a non-reversible way, the change in the electronic properties can be reve…
Epitaxial graphene grown on transition metal surfaces typically exhibits a moiré pattern due to the lattice mismatch between graphene and the underlying metal surface. We use both scanning tunneling microscopy (STM) and atomic force microscopy (AFM) experiments to probe the electronic and topographic contrast of the graphene moiré on the Ir(111) surface. While STM topography is influenced by the local density of states close to the Fermi energy and the local tunneling barrier height, AFM is capable of yielding the 'true' surface topography once the background force arising from the van der Waa…
In this paper we demonstrate atomic-scale lithography on hydrogen terminated Ge(001. The lithographic patterns were obtained by selectively desorbing hydrogen atoms from a H resist layer adsorbed on a clean, atomically flat Ge(001) surface with a scanning tunneling microscope tip operating in ultra-high vacuum. The influence of the tip-to-sample bias on the lithographic process have been investigated. Lithographic patterns with feature-sizes from 200 nm to 1.8 nm have been achieved by varying the tip-to-sample bias. These results open up the possibility of a scanning-probe lithography approach…
We report a detailed study of tunneling spectra measured on 2H-Ta$_x$Nb$_{1-x}$Se$_2$ ($x=0\sim 0.1$) single crystals using a low-temperature scanning tunneling microscope. The prominent gap-like feature unintelligible for a long time was found to be accompanied by some "in-gap" fine structures. By investigating the second-derivative spectra and their temperature and magnetic field dependencies, we were able to prove that inelastic electron tunneling is the origin of these features and obtain the Eliashberg function of 2H-Ta$_x$Nb$_{1-x}$Se$_2$ at atomic scale, providing a potential way to stu…
A carbon nanotube (CNT) tip was fabricated at the apex of an etched tungsten wire by chemical vapor deposition and used for scanning tunneling microscopy. The honeycomb lattice of graphite in the STM images was resolved with a CNT tip at T=79 K. The superior spatial resolution originating from the p orbitals of a CNT is responsible for the image of the honeycomb lattice of graphite in the STM images. The CNT tips are useful to image samples whose lattice constants are small and to get orbital information in samples with orbital ordering due to their superior spatial resolution with the sharp p…
The growth and atomic/electronic structure of molecular beam epitaxy (MBE)-grown ErAs nanoparticles and nanorods embedded within a GaAs matrix are examined for the first time via cross-sectional scanning tunneling microscopy (XSTM) and spectroscopy (XSTS). Cross sections enable the interrogation of the internal structure and are well suited for studying embedded nanostructures. The early stages of embedded ErAs nanostructure growth are examined via these techniques and compared with previous cross sectional TEM work. Tunneling spectroscopy I(V) for both ErAs nanoparticles and nanorods was also…
Nanoscale 3D surface modifications, by scanning tunneling microscopy under ambient conditions, of La0.7Sr0.3MnO3 thin films have been performed. It was demonstrated that there are well defined combinations of bias voltages and scan speeds which allow for controlled surface structuring. Lateral structures with sizes down to 1.5 nm are possible to obtain. Moreover, it is possible to reproducibly control the depth of etching with half a unit cell precision, enabling design of 3D surface structures and control of the surface termination of La0.7Sr0.3MnO3 through etching.
Using low energy electron diffraction (LEED), scanning tunnelling microscopy (STM) and x-ray absorption spectroscopy (XAS) techniques, we have studied the first steps of silicon adsorption onto Cu (001) single crystal substrate. For low coverage (~ 0.5 ML) and after annealing at 100°C, STM images and LEED patterns reveal the formation of an ordered quasi commensurate superstructure. From a quantitative analysis of XAS data, we extract the Si-Cu distance and detail the local atomic arrangement of the structure.
We consider the magnetic structure on the Fe(001) surface and theoretically study the scanning tunneling spectroscopy using a spin-polarized tip (SP-STM). We show that minority-spin surface states induce a strong bias dependence of the tunneling differential conductance which largely depends on the orientation of the magnetization in the SP-STM tip relative to the easy magnetization axis in the Fe(001) surface. We propose to use this effect in order to determine the spin character of the Fe(001) surface states. This technique can be applied also to other magnetic surfaces in which surface stat…
We have developed a method for depositing graphene monolayers and bilayers with minimum lateral dimensions of 2-10 nm by the mechanical exfoliation of graphite onto the Si(100)-2x1:H surface. Room temperature, ultra-high vacuum (UHV) tunnelling spectroscopy measurements of nanometer-sized single-layer graphene reveal a size dependent energy gap ranging from 0.1-1 eV. Furthermore, the number of graphene layers can be directly determined from scanning tunnelling microscopy (STM) topographic contours. This atomistic study provides an experimental basis for probing the electronic structure of nano…
The mechanisms underlying the intrinsic photoresponse of few-layer (FL) molybdenum disulphide (MoS2) field-effect transistors are investigated via scanning photocurrent microscopy. We attribute the locally enhanced photocurrent to band-bending assisted separation of photoexcited carriers at the MoS2/Au interface. The wavelength-dependent photocurrents of few layer MoS2 transistors qualitatively follow the optical absorption spectra of MoS2, providing direct evidence of interband photoexcitation. Time and spectrally resolved photocurrent measurements at varying external electric fields and carr…
We apply high resolution scanning tunneling microscopy to study intrinsic defect states of bulk FeSe. Four types of intrinsic defects including the type I dumbbell, type II dumbbell, top-layer Se vacancy and inner-layer Se-site defect are extensively analyzed by scanning tunneling spectroscopy. From characterized depression and enhancement of density of states measured in a large energy range, the type I dumbbell and type II dumbbell are determined to be the Fe vacancy and Se$_\mathrm{Fe}$ defect, respectively. The top-layer Se vacancy and possible inner-layer Se-site vacancy are also determin…
The presence of structure-dependent edge states of graphite is revealed by both ambient- and ultra-highvacuum- (UHV) scanning tunneling microscopy (STM) / scanning tunneling spectroscopy (STS) observations. On a hydrogenated zigzag (armchair) edge, bright spots are (are not) observed together with (SQRT(3) by SQRT(3))R30 superlattice near the Fermi level (V_S = −30 mV for a peak of the local density of states (LDOS)) under UHV, demonstrating that a zigzag edge is responsible for the edge states, although there is no appreciable difference between as-prepared zigzag and armchair edges in …
Fast scanning probe microscopy enabled via machine learning allows for a broad range of nanoscale, temporally resolved physics to be uncovered. However, such examples for functional imaging are few in number. Here, using piezoresponse force microscopy (PFM) as a model application, we demonstrate a factor of 5.8 improvement in imaging rate using a combination of sparse spiral scanning with compressive sensing and Gaussian processing reconstruction. It is found that even extremely sparse scans offer strong reconstructions with less than 6 % error for Gaussian processing reconstructions. Further,…
The search for topological phases of matter is evolving towards strongly interacting systems, including magnets and superconductors, where exotic effects emerge from the quantum-level interplay between geometry, correlation and topology. Over the past decade or so, scanning tunnelling microscopy has become a powerful tool to probe and discover emergent topological matter, because of its unprecedented spatial resolution, high-precision electronic detection and magnetic tunability. Scanning tunnelling microscopy can be used to probe various topological phenomena, as well as complement results fr…