Currently in HDR brachytherapy planning, a manual fine-tuning of an objective function is necessary to obtain case-specific valid plans. This study intends to facilitate this process by proposing a patient-specific inverse planning algorithm for HDR prostate brachytherapy: GPU-based multi-criteria optimization (gMCO).
Two GPU-based optimization engines including simulated annealing (gSA) and a quasi-Newton optimizer (gL-BFGS) were implemented to compute multiple plans in parallel. After evaluating the equivalence and the computation performance of these two optimization engines, one preferred optimization engine was selected for the gMCO algorithm. Five hundred sixty-two previously treated prostate HDR cases were divided into validation set (100) and test set (462). In the validation set, the number of Pareto optimal plans to achieve the best plan quality was determined for the gMCO algorithm. In the test set, gMCO plans were compared with the physician-approved clinical plans.
Over 462 cases, the number of clinically valid plans was 428 (92.6%) for clinical plans and 461 (99.8%) for gMCO plans. The number of valid plans with target V100 coverage greater than 95% was 288 (62.3%) for clinical plans and 414 (89.6%) for gMCO plans. The mean planning time was 9.4 s for the gMCO algorithm to generate 1000 Pareto optimal plans.
In conclusion, gL-BFGS is able to compute thousands of SA equivalent treatment plans within a short time frame. Powered by gL-BFGS, an ultra-fast and robust multi-criteria optimization algorithm was implemented for HDR prostate brachytherapy. A large-scale comparison against physician approved clinical plans showed that treatment plan quality could be improved and planning time could be significantly reduced with the proposed gMCO algorithm.
From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy
Clinical test cases for commissioning, QA, and benchmarking of model-based dose calculation algorithms in 192Ir HDR gynecologic tandem and ring brachytherapy
National and Kapodistrian University of Athens(雅典国立卡波季斯里安大学);General Hospital of Athens Alexandra(亚历山德拉雅典综合医院);McGill University(麦吉尔大学);Carleton University(卡尔顿大学);Thomas Jefferson University(托马斯杰斐逊大学);Maastricht University Medical Centre+(马斯特里赫特大学医学中心+)
Automated Treatment Planning for Interstitial HDR Brachytherapy for Locally Advanced Cervical Cancer using Deep Reinforcement Learning
Department of Radiation & Cellular Oncology, University of Chicago(芝加哥大学辐射与细胞肿瘤学系);Department of Physics, University of Chicago(芝加哥大学物理系);Department of Radiation Oncology, Emory University(埃默里大学放射肿瘤学系)
Development and pilot evaluation of a virtual reality simulator for HDR prostate brachytherapy
Toronto Metropolitan University(多伦多都会大学);Sunnybrook Health Sciences Center(森尼布鲁克健康科学中心);University of Toronto(多伦多大学);London Health Sciences Center(伦敦健康科学中心);Western University(韦仕敦大学);Henry Ford Health(亨利福特医疗);Michigan State University(密歇根州立大学)
Automatic Treatment Planning using Reinforcement Learning for High-dose-rate Prostate Brachytherapy
Department of Medical Physics, Memorial Sloan Kettering Cancer Center(医学物理系,纪念斯隆-凯特琳癌症中心);Department of Radiation Oncology and Winship Cancer Institute, Emory University(放射肿瘤学系和Winship癌症研究所,埃默里大学);Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine(Wallace H. Coulter生物医学工程系,佐治亚理工学院和埃默里大学医学院);Department of Biomedical Informatics, Emory University(生物医学信息学系,埃默里大学)