arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2510.25944physics.med-phphysics.ed-ph
收藏

用于高剂量率前列腺近距离治疗的虚拟现实模拟器的开发与初步评估

Development and pilot evaluation of a virtual reality simulator for HDR prostate brachytherapy

Toronto Metropolitan University(多伦多都会大学);Sunnybrook Health Sciences Center(森尼布鲁克健康科学中心);University of Toronto(多伦多大学);London Health Sciences Center(伦敦健康科学中心);Western University(韦仕敦大学);Henry Ford Health(亨利福特医疗);Michigan State University(密歇根州立大学)

Anton Varlukhin, Mackenzie Smith, Fahad Alam, Amandeep Tagger, Gerard Morton, Moti Paudel, Andrew Loblaw, Lucas Mendez, Douglas Hoover, Raffi Karshafian, Humza Nusrat

AI总结:

本研究开发了基于Unreal Engine的HDR前列腺近距离治疗VR模拟器,含患者准备与针插入两个模块,经两个队列验证,训练后受试者在操作步骤、设备相关的多维度信心均显著提升,可为相关课程设计提供参考。

摘要:

目的:开发一款用于高剂量率(HDR)前列腺近距离治疗的虚拟现实模拟器,并测试参与该模拟器训练是否与两个队列中预先定义的操作领域的自我报告信心即时提升相关。方法:使用Unreal Engine(虚幻引擎)开发并实现了两个模块:患者准备模块与模板引导下的针插入模块。肿瘤科工作人员与受训人员完成了训练前后的调查问卷,评估内容包括回忆操作步骤、讲解操作步骤、识别设备以及讲解设备功能的信心。研究分别在安大略省伦敦市的Hands On Brachytherapy Workshop(HOWBT,近距离治疗实操研讨会)和安大略省多伦多市的Sunnybrook Odette Cancer Centre开展。采用双侧p值的配对Wilcoxon符号秩检验,对比每个模块训练前后的得分。结果:患者准备模块(N=11)中,回忆步骤(W=65,p=0.002)、讲解步骤(W=51,p=0.023)、识别设备(W=65,p=0.002)及讲解设备功能(W=60,p=0.0078)的信心均有所提升。针插入模块(N=27)中,回忆步骤(W=292,p<0.001)、讲解步骤(W=347,p<0.001)、识别设备(W=355,p<0.001)及讲解设备功能(W=354,p<0.001)的信心均有所提升。结论:该模拟器部署可行,且与训练后关键操作领域的自我报告信心提升相关。研究结果可为未来的课程设计与实施工作提供参考。

英文摘要:

Purpose: To develop a virtual reality simulator for high dose rate prostate brachytherapy and to test whether participation is associated with immediate gains in self-reported confidence across predefined procedural domains in two cohorts. Methods: Two modules were developed and implemented using Unreal Engine: patient preparation and template guided needle insertion. Oncology staff and trainees completed pre and post surveys that assessed confidence for recalling steps, explaining steps, identifying equipment, and explaining equipment function. Studies were conducted at the Hands On Brachytherapy Workshop (HOWBT) in London, Ontario, and at Sunnybrook Odette Cancer Centre in Toronto, Ontario. Paired Wilcoxon signed rank tests with two-sided p values compared before and after scores within each module. Results: Patient preparation (N=11) confidence increased for recalling steps (W=65, p=0.002), explaining steps (W=51, p = 0.023), identifying equipment (W=65, p=0.002), and explaining equipment function (W=60, p=0.0078). Needle insertion (N=27) confidence increased for recalling steps (W=292, p<0.001), explaining steps (W=347, p<0.001), identifying equipment (W=355, p<0.001), and explaining equipment function (W=354, p<0.001). Conclusion: The simulator was feasible to deploy and was associated with higher self-reported confidence across key domains immediately after training. Findings may inform future curriculum design and implementation work.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑