arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1901.03294astro-ph.EPastro-ph.IM
收藏

HARPS摄谱仪的新波长标定

New wavelength calibration of the HARPS spectrograph

Adrien Coffinet, Christophe Lovis, Xavier Dumusque, Francesco Pepe

摘要:

即使HARPS摄谱仪已经运行了15年以上,并且它提供了最精确的多普勒测量,改进仍然是可能的。例如,一个已知的问题是CCD的非完全规则的块拼接,其在某些情况下在测量的径向速度中引入一年周期的寄生信号。其目的是改善HARPS的波长校准,以进一步推动其行星探测能力。的CCD曝光引起的像素大小异常的属性确定与LED平场帧,然后一个物理的,间隙校正的CCD的地图用于拟合模型的光谱阶。我们还使用了一个新的钍线列表,其基于比迄今为止使用的精确度高得多的测量。在2015年光纤升级之前和之后,我们为15年的HARPS数据推导了新的波长解决方案。我们证明,我们校正间隙异常计算的波长解决方案的激光频率梳曝光,无论是考虑和不考虑间隙校正。通过比较HARPS样本中最稳定的恒星的均方根,我们表明,我们在全球范围内降低了数据的径向速度色散,特别是对于改变纤维后获得的数据。最后,几个单独的系统的比较分析表明,我们设法衰减的周期图功率在大多数情况下,在一年。对单个恒星谱线的RV分析也表明,我们修正了辐射引起的RV变化。HARPS光谱仪的这种改进的校准允许更深入地搜索低振幅径向速度信号。通过将钍校准谱与激光频率梳和法布里-珀罗校准谱相结合,不仅对HARPS,而且对HARPS-N和ESTENO也有进一步的改进。

英文摘要:

(abridged) Even if the HARPS spectrograph has been operational for more than 15 years and it provides among the most precise Doppler measurements, improvements are still possible. One known problem, for instance, is the non-fully regular block-stitching of the CCDs, which introduces, in some cases, one-year period parasitic signals in the measured radial velocity. The aim is to improve the wavelength calibration of HARPS to push further its planet-detection capabilities. The properties of the CCD stitching-induced pixel-size anomalies are determined with LED flat-field frames, and then a physical, gap-corrected map of the CCDs is used for the fitting model of the spectral orders. We also use a new thorium line list, based on much higher-accuracy measurements than the one used up to now. We derive new wavelength solutions for the 15 years of HARPS data, both before and after the 2015 fibre upgrade. We demonstrate that we correct the gap anomalies by computing the wavelength solutions of laser frequency comb exposures, both with and without taking the gap correction into account. By comparing the rms of the most stable stars of the HARPS sample, we show that we globally decrease the radial velocity dispersion of the data, especially for the data acquired after the change of fibres. Finally, the comparative analysis of several individual systems shows that we manage to attenuate the periodogram power at one year in most cases. The analysis of the RVs derived from individual stellar lines also shows that we correct the stitching-induced RV variation. This improved calibration of the HARPS spectrograph allows to go deeper in the search for low-amplitude radial-velocity signals. It will be further improved by combining the thorium calibration spectra with laser frequency comb and Fabry-Perot calibration spectra, and not only for HARPS but notably also for HARPS-N and ESPRESSO.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑