arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1403.6841astro-ph.IMastro-ph.EP
收藏

光纤法布里-珀罗干涉仪作为高分辨率光谱仪稳定近红外定标源的研制

Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared Calibration Sources for High Resolution Spectrographs

Samuel Halverson, Suvrath Mahadevan, Lawrence Ramsey, Fred Hearty, John Wilson, Jon Holtzman, Stephen Redman, Gillian Nave, David Nidever, Matt Nelson, Nick Ven… 展开作者

Samuel Halverson, Suvrath Mahadevan, Lawrence Ramsey, Fred Hearty, John Wilson, Jon Holtzman, Stephen Redman, Gillian Nave, David Nidever, Matt Nelson, Nick Venditti, Dmitry Bizyaev, Scott Fleming

摘要:

我们讨论了单模光纤法布里-珀罗(FFP)干涉仪作为高精度径向速度(RV)光谱仪的精确天文光子校准源的持续发展。FFP是简单、廉价的单片单元,可以产生稳定和可重复的输出光谱。FFP是传统标准具的独特替代品,因为干涉腔由单模光纤而不是气隙间隔器制成。这种设计允许出色的准直,高光谱精细度,刚性机械稳定性,对振动不敏感,并且不需要真空操作。我们测试的设备是Micron Optics的市售产品。我们的发展道路是针对校准源的可扩展区行星光谱仪(HPF),近红外光谱仪,旨在检测低质量恒星周围的地球质量行星,但这个参考也可以用于许多现有的和计划中的光纤光谱仪,因为我们说明使用Apache点天文台星系演化实验(APOGEE)仪器。通过对光纤标准具的精确温度控制,我们实现了100 $μ$ K的热稳定性和22 cm s $^{-1}$的相关速度不确定性。我们实现了$\approx$ 2 m s $^{-1}$的精度在一个单一的APOGEE光纤超过12小时,使用这个新的光子参考后,删除系统的相关性。这种高精度(接近预期的光子极限下限)证明了光纤干涉仪出色的固有波长稳定性和APOGEE仪器设计的稳定性。当在所有300个APOGEE光纤上取平均值并去除已知趋势和压力相关性后,12小时内的总体仪器速度精度为80 cm s $^{-1}$,这意味着光纤标准具在本质上稳定到显著更高的精度。

英文摘要:

We discuss the ongoing development of single-mode fiber Fabry-Perot (FFP) Interferometers as precise astro-photonic calibration sources for high precision radial velocity (RV) spectrographs. FFPs are simple, inexpensive, monolithic units that can yield a stable and repeatable output spectrum. An FFP is a unique alternative to a traditional etalon, as the interferometric cavity is made of single-mode fiber rather than an air-gap spacer. This design allows for excellent collimation, high spectral finesse, rigid mechanical stability, insensitivity to vibrations, and no need for vacuum operation. The device we have tested is a commercially available product from Micron Optics. Our development path is targeted towards a calibration source for the Habitable-Zone Planet Finder (HPF), a near-infrared spectrograph designed to detect terrestrial-mass planets around low-mass stars, but this reference could also be used in many existing and planned fiber-fed spectrographs as we illustrate using the Apache Point Observatory Galactic Evolution Experiment (APOGEE) instrument. With precise temperature control of the fiber etalon, we achieve a thermal stability of 100 $μ$K and associated velocity uncertainty of 22 cm s$^{-1}$. We achieve a precision of $\approx$2 m s$^{-1}$ in a single APOGEE fiber over 12 hours using this new photonic reference after removal of systematic correlations. This high precision (close to the expected photon-limited floor) is a testament to both the excellent intrinsic wavelength stability of the fiber interferometer and the stability of the APOGEE instrument design. Overall instrument velocity precision is 80 cm s$^{-1}$ over 12 hours when averaged over all 300 APOGEE fibers and after removal of known trends and pressure correlations, implying the fiber etalon is intrinsically stable to significantly higher precision.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑