arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1811.01005physics.ins-detnucl-ex
收藏

测量0.2 - 2 MeV中子能中子通量的气体质子反冲探测器的研制

Development of a gaseous proton-recoil detector for neutron flux measurements between 0.2 and 2 MeV neutron energy

Paola Marini, Ludovic Mathieu, Mourad Aïche, Serge Czajkowski, Beatriz Jurado, Igor Tsekhanovich

摘要:

中子注量率的绝对测量是中子感生截面测量、中子束线表征和剂量学研究的必要前提。H(n,p)弹性散射截面是用于在高精度测量中执行精确的中子通量测量的非常公知的标准。使用这种技术,与质子反冲探测器,是不直接低于1兆电子伏的入射中子能量,由于在检测到的质子谱的高背景。在AIFIRA设施进行了实验,以调查这种背景并确定其来源和组成。在此基础上,设计了一种低能本底较低的气体质子反冲探测器。该探测器的第一次测试已在AIFIRA设施进行,并将提交第一批结果。

英文摘要:

Absolute measurements of neutron fluence are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. The H(n,p) elastic scattering cross section is a very well known standard used to perform precise neutron flux measurements in high precision measurements. The use of this technique, with proton recoil detectors, is not straightforward below incident neutron energy of 1 MeV, due to a high background in the detected proton spectrum. Experiments have been carried out at the AIFIRA facility to investigate such background and to determine its origin and components. Based on these investigations, a gaseous proton-recoil detector has been designed with a reduced low energy background. A first test of this detector has been carried out at the AIFIRA facility, and first results will be presented.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑