In this study, we have developed a new sub-MeV neutron detector that has a high position resolution, energy resolution, directional sensitivity, and low background. The detector is based on a super-fine-grained nuclear emulsion, called the Nano Imaging Tracker (NIT), and it is capable of detecting neutron induced proton recoils as tracks through topological analysis with sub-micrometric accuracy. We used a type of NIT with AgBr:I crystals of (98 +- 10) nm size dispersed in the gelatin. First, we calibrated the performance of NIT device for detecting monochromatic neutrons with sub-MeV energy generated by nuclear fusion reactions, and the detection efficiency for recoil proton tracks of more than 2 um range was consistently 100\% (the 1 sigma lower limit was 83%) in accordance with expectations by manual based analysis. In addition, recoil energy and angle distribution obtained good agreement with kinematical expectation. The primary neutron energy was reconstructed by using them, and it was evaluated as 42% with FWHM at 540 keV. Furthermore, we demonstrated newly developed an automatic track recognition system dedicated to the track range of more than a few micrometers. It achieved a recognition efficiency of (74 +- 4)%, and recoil energy and angle distribution obtained good agreement with manual analysis. Finally, it indicated the very high rejection power for gamma-rays.
Optical shape analysis based on discrete Fourier transform and second order moment calculation of the brightness distribution for the detection of sub-micron range low energy tracks
Toward High-Resolution Detection of Target Fragmentation: TEA-Sensitized NIT for Proton Therapy Applications
Toho University(东海大学);University of Torino(都灵大学);University of Piemonte Orientale(皮埃蒙特东方大学);CNRS/Université de Strasbourg(法国国家科学研究中心/斯特拉斯堡大学);University of Pisa(比萨大学);INFN, Gran Sasso National Laboratories(意大利国家核物理研究所,格兰萨索国家实验室);University of Napoli Federico II(那不勒斯费德里科二世大学);University of Foggia(福贾大学);University of Bologna(博洛尼亚大学);Sapienza University of Rome(罗马第一大学);Nagoya City University West Medical Center(名古屋市立大学西医疗中心);University of Trento(特伦托大学);National Institutes for Quantum Science and Technology (QST)(量子科学技术研究开发机构);University of Bari(巴里大学);University of Camerino(卡梅里诺大学);University of Rome Tor Vergata(罗马第二大学);University of Perugia(佩鲁贾大学);INFN, Frascati National Laboratories(意大利国家核物理研究所,弗拉斯卡蒂国家实验室);Nagoya University(名古屋大学)
A new method for an improved anti-neutrino energy reconstruction with charged-current interactions in next-generation detectors
我们提出并验证了一种方法的反中微子能量重建的带电电流无介子相互作用的复合材料完全活性目标含有氢(如碳氢化合物闪烁体),这是在很大程度上不了解的核效应,通常扭曲和偏见试图测量中微子能量。该方法是基于精确的事件的事件,由事件测量的传出中子动能和随后的评估的动量不平衡的平面上的横向传入的反中微子方向。对于使用细粒度$2\times2\times2$ m $^3$ 3D闪烁体跟踪器测量的峰值约为600 MeV的反中微子通量,中微子能量分辨率预计约为7%,而使用传统中微子能量重建技术预计为15%。对于具有类似特性的其他探测器,可以获得类似的结果。
The Super Fine-Grained Detector for the T2K neutrino oscillation experiment
University of Tokyo(东京大学);Institute for Cosmic Ray Research(宇宙线研究所);Kamioka Observatory(神冈观测所);Lancaster University(兰卡斯特大学);Lebedev Physical Institute of the Russian Academy of Sciences(俄罗斯科学院列别杰夫物理研究所);Tokyo Metropolitan University(东京都立大学);Kyoto University(京都大学);Joint Institute for Nuclear Research(联合核研究所);Louisiana State University(路易斯安那州立大学);Oxford University(牛津大学);Bartoszek Engineering(巴托舍克工程公司);Institute for Nuclear Research of the Russian Academy of Sciences(俄罗斯科学院核研究所);Ecole Polytechnique(巴黎综合理工学院);IN2P3-CNRS(法国国家科学研究中心IN2P3);Laboratoire Leprince-Ringuet(勒布朗-林盖特实验室);Tohoku University(东北大学);Sorbonne Université(索邦大学)