Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment
A. Anastasi, A. Basti, F. Bedeschi, M. Bartolini, G. Cantatore, D. Cauz, G. Corradi, S. Dabagov, G. DI Sciascio, R. Di Stefano, A. Driutti, O. Escalante, C. Fer… 展开作者
A. Anastasi, A. Basti, F. Bedeschi, M. Bartolini, G. Cantatore, D. Cauz, G. Corradi, S. Dabagov, G. DI Sciascio, R. Di Stefano, A. Driutti, O. Escalante, C. Ferrari, A. T. Fienberg, A. Fioretti, C. Gabbanini, A. Gioiosa, D. Hampai, D. W. Hertzog, M. Iacovacci, M. Karuza, J. Kaspar, A. Liedl, A. Lusiani, F. Marignetti, S. Mastroianni, D. Moricciani, G. Pauletta, G. M. Piacentino, N. Raha, E. Rossi, L. Santi, G. Venanzoni
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.
The calibration procedure of a finely granulated digital hadron calorimeter with Resistive Plate Chambers as active elements is described. Results obtained with a stack of nine layers exposed to muons from the Fermilab test beam are presented.
The SoLid experiment aims to make a measurement of very short distance neutrino oscillations using reactor antineutrinos. Key to its sensitivity are the experiments high spatial and energy resolution, combined with a very suitable reactor source and efficient background rejection. The fine segmentation of the detector (cubes of side 5cm), and ability to resolve signals in space and time, gives SoLid the capability to track cosmic muons. In principle a source of background, these turn into a valuable calibration source if they can be cleanly identified. This work presents the first energy calib…
The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 ÷1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of the SND detector with cosmic muons is described. Using this method, the energy resolution of $5.5 % (σ)$ for 500 MeV photons was achieved.
The ATLAS muon spectrometer is designed to measure muon momenta with a resolution of 4% @ 100 GeV/c rising to 10% @ 1 TeV/c track momentum. The spectrometer consists of precision tracking and trigger chambers embedded in a 2T magnetic field generated by three large air-core superconducting toroids. The precision detectors provide 50 micron tracking resolution to a pseudo-rapidity of 2.7. The system also includes an optical monitoring system which measures detector positions with 40 micron precision. This paper reports on the calibration and performance of the ATLAS muon spectrometer.
Large-scale computing in ATLAS is based on a grid-linked system of tiered computing centers. The ATLAS Great Lakes Tier-2 came online in September 2006 and now is commissioning with full capacity to provide significant computing power and services to the USATLAS community. Our Tier-2 Center also host the Michigan Muon Calibration Center which is responsible for daily calibrations of the ATLAS Monitored Drift Tubes for ATLAS endcap muon system. During the first LHC beam period in 2008 and following ATLAS global cosmic ray data taking period, the Calibration Center received a large data stream f…
The results of the extended quadrahedral NaI(Tl) spectrometer`s calibration by cosmic muons are presented. The signal amplitude and energy resolution of the spectrometer have complex dependencies on the voltage at the photomultiplier and the entry point of the particle into the spectrometer in the transverse direction. When the voltage across the photomultiplier divider photomultiplier is U = 1150 V the homogeneous signals area is observed at about 90% of the spectrometer length, the energy resolution is about 7%.
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration progr…
Calibration of the discriminator threshold of the Amplifier-Shaper-Discriminator Chip for the Upgrade of the ATLAS Muon Drift-Tube Chambers for the High-Luminosity LHC
This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the calibration is to determine, for each drift cell, the minimum time delay for signals relative to the trigger, accounting for the drift velocity within the cell. The accuracy of the calibration procedure is influenced by the random arrival time of the cosmic muons relative to the LHC clock cycle. A more refined analysis of the drift velocity was performed during the …
The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.
A high power pulsed laser system has been installed on the high magnetic field muon spectrometer (HiFi) at the ISIS pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high magnetic field, which opens new applications of muon spin spectroscopy. In this report we give an overview of the principle of the HiFi Laser system, and describe the newly developed techniques and devices that enable precisely controlled photoexcitation of samples in the muon instrument. A demonstration e…
Shashlyk-type electromagnetic calorimeter (ECal) of the Multi-Purpose Detector at heavy-ion NICA collider is optimized to provide precise spatial and energy measurements for photons and electrons in the energy range from about 40 MeV to 2-3 GeV. To deal with high multiplicity of secondary particles from Au-Au reactions, ECal has a fine segmentation and consists of 38,400 cells ("towers"). Given the big number of "towers" and the time constraint, it is not possible to calibrate every ECal "tower" with beam. In this paper, we describe the strategy of the first-order calibration of ECal with cosm…
We report on the calibration of a superfluid $^3$He bolometer developed for the search of non-baryonic Dark Matter. Precise thermometry is achieved by the direct measurement of thermal excitations using Vibrating Wire Resonators (VWRs). The heating pulses for calibration were produced by the direct quantum process of quasiparticle generation by other VWRs present. The bolometric calibration factor is analyzed as a function of temperature and excitation level of the sensing VWR. The calibration is compared to bolometric measurements of the nuclear neutron capture reaction and heat depositions b…
A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approximately 1 cubic meter large calorimeter allow large sample studies of behavior of these devices under varying voltage and temperature as well as their saturation behavior. We also present detailed studies of the temperature dependence of the calorimeter signal in muon and hadron beams. The calibrati…
The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system based on a fast laser diode and a system based on one optical switch, several $1 \times 10$ fused fiber splitters, ultra-high vacuum optical feedthroughs and multimode optical patchcords up to 20 m lon…
We have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (MuSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H-) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam accounts for only 0.2% of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neu…
In this work, we describe the calibration and first measurements in the commissioning of MuTe, a hybrid Muon Telescope with two subdetectors --a scintillator hodoscope and a Water Cherenkov Detector (WCD)-- for imaging the inner structures of Colombian volcanoes. The hodoscope estimates the trajectories of particles impinging on the front and rear panel, while the WCD acts as a calorimeter for the through going charged particle. MuTe combines particle identification techniques so as to discriminate noise background from data. It filters the primary noise sources for muography, i.e., the EM-com…
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100 ps and ~1-2 cm, respectively. These values are comparable to those obtained from cosmic-ray bench tests and test beams.
A UV laser calibration system is developed for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based, long baseline reactor anti-neutrino experiment. This system is capable of delivering fast laser pulses (<1 ns) into the detector with a photon intensity ranging from hundreds of keV to a few TeV equivalent energy. An independent intensity monitoring system is developed for this laser, which has achieved a < 0.3% relative uncertainty. Such a system will be used to calibrate the response of the JUNO photosensors and electronics in situ to a sub-percent precisi…
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked.
We performed photometric calibration of the PhotoMultiplier Tube (PMT) and readout electronics used for the new fluorescence detectors of the Telescope Array (TA) experiment using Rayleigh scattered photons from a pulsed nitrogen laser beam. The experimental setup, measurement procedure, and results of calibration are described. The total systematic uncertainty of the calibration is estimated to be 7.2%. An additional uncertainty of 3.7% is introduced by the transport of the calibrated PMTs from the laboratory to the TA experimental site.
Usage of secondary cosmic muons to image the geological structures density distribution significantly developed during the past ten years. Recent applications demonstrate the method interest to monitor magma ascent and volcanic gas movements inside volcanoes. Muon radiography could be used to monitor density variations in aquifers and the critical zone in the near surface. However, the time resolution achievable by muon radiography monitoring remains poorly studied. It is biased by fluctuation sources exterior to the target, and statistically affected by the limited number of particles detecte…
This article describes the Laser calibration system of the Atlas hadronic Tile Calorimeter that has been used during the run 1 of the LHC. First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for …
The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calori…
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the g…
Calibration of three scintillators (EJ232Q, BC422Q and EJ410) in a time-of-flight (TOF) arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors are shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.
In 2002 the first combined beam test of the hadronic and electromagnetic liquid-argon endcap calorimeters of the ATLAS experiment took place at the SPS test beam at CERN. A total of 15 million events from electrons, muons and pions in the energy range from 6 to 200 GeV were recorded. The entire calibration chain, from digital filter weights, over calibration constants, to clustering and energy weights, as is relevant for the energy calibration of hadronic and electromagnetic showers in ATLAS was tested and applied to the beam test data. The calibration methods and first results for the combine…
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator count…
We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method s…
Laser power metrology at the National Institute of Standards and Technology (NIST) ranges 20 orders of magnitude from photon-counting (1000 photons/s) to 100 kW (10^23 photons/s at a wavelength of 1070 nm). As a part of routine practices, we perform internal (unpublished) comparisons between our various power meters to verify correct operation.
As sensitivities improve and more detectors are added to the global network of gravitational wave observatories, calibration accuracy and precision are becoming increasingly important. Photon calibrators, relying on power-modulated auxiliary laser beams reflecting from suspended interferometer optics, enable continuous calibration by generating displacement fiducials proportional to the modulated laser power. Developments in the propagation of laser power calibration via transfer standards to on-line power sensors monitoring the modulated laser power have enabled generation of length fiducials…
In this study, we developed an automated, multipoint primary accelerometer calibration system using a two-axis positioning stage and a heterodyne laser interferometer. The proposed system offers low-cost, convenient, and automated multipoint accelerometer calibration, enabling less calibration lead time. The positioning stage also offers better positioning repeatability of 1 um, which is impossible through manual alignments. We measured the surface deformation of a laser reflection adaptor for a single-ended accelerometer by measuring more than 450 measurement positions. Visualizing the deform…
A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of multi-channels time-of-flight (TOF) detectors with photomultipliers' (PMTs') readout. As available laser diode sources have unfortunately limited peak power, the main experimental problem is the tight light power budget of such a system. In addition, while the technology for fused fiber splitters is common in the Telecom wavelength range ($λ\sim 850, 1300-1500$ nm), it …
The results of calibration by cosmic muons of a shower lead-scintillation spectrometer of the sandwich type designed to work in high-intensity photon and electron beams with an energy of 0.1 - 1.0 GeV are presented. It was found that the relative energy resolution of the spectrometer depends on the angle of entry of cosmic muons into the spectrometer in the vertical plane and does not depend on the angle of entry in the horizontal plane. The relative energy resolution of the spectrometer was 16%. Placing an additional lead-scintillation assembly in front of the spectrometer improved the relati…
We designed a simple setup to measure the muon lifetime and the electron energy spectra of muon decay. A low cost coincidental circuit was designed to select the signals of muon decay events detected by a plastic scintillator detector. It triggered a digital oscilloscope to record the signals of muon decay events for measuring the muon lifetime and electron energy spectrum. A Landau-distribution energy loss method was introduced to conduct the energy calibration of the system. The experimental results were well reproduced by the Monte Carlo simulation. The software and hardware of the system a…
Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibr…
We analyze $μ^+μ^-$ pair production generated by high-energy electrons emerging from a laser-wakefield accelerator. The $μ^+μ^-$ pairs are created in a solid thick high-$Z$ target, following the electron accelerating plasma region. Numerical estimates are presented for electron beams obtained presently in the LBL TW laser experiment \cite{C2} and possible future developments. Reactions induced by the secondary bremsstrahlung photons dominate the dimuon production. According to our estimates, a 20 pC electron bunch with energy of 1 (10) GeV may create about 200 (6000) muon pairs. The produced $…
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration system…
A number of liquid argon time projection chambers (LAr TPC's) are being build or are proposed for neutrino experiments on long- and short baseline beams. For these detectors a distortion in the drift field due to geometrical or physics reasons can affect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration…
The MicroBooNE experiment is a liquid argon TPC experiment designed for short-baseline neutrino physics, currently running at Fermilab. Due to its location near the surface, cosmic muons can be a source of backgrounds to many analyses and having a good understanding of the cosmic rays will be very valuable for the experiment. These proceedings describe the physics motivation, setup, and performance of a small external muon counter system, which will provide improved calibration for the liquid argon TPC and better understanding of the cosmogenic background.
Muons from cosmic-ray interactions in the atmosphere provide a high-statistics source of particles that can be used to study the performance and calibration of the ATLAS detector. Cosmic-ray muons can penetrate to the cavern and deposit energy in all detector subsystems. Such events have played an important role in the commissioning of the detector since the start of the installation phase in 2005 and were particularly important for understanding the detector performance in the time prior to the arrival of the first LHC beams. Global cosmic-ray runs were undertaken in both 2008 and 2009 and th…
A new calibration technique using natural background light of sea water has been recently developed for the ANTARES experiment. The method relies on correlated coincidences produced in triplets of optical modules by Cherenkov light of beta-particles originated from Potassium-40 decays. A simple but powerful approach to atmospheric muon flux studies is currently being developed based on similar ideas of coincidence analysis. This article presents the two methods in certain detail and explains their role in the ANTARES experiment.
The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to the ten PMTs connected to a single flange, by 7m long injection optical patches. Extensive tests of the used components and care in the design of the optical system have guaranteed to each PMT a sizeable calibration signal with minimal distortion, with respect to the original one. Gain equalization of PMTs has reached a 1 per cent resolution. In this proced…
The ANTARES experiment consists of an array of photomultipliers distributed along 12 lines and located deep underwater in the Mediterranean Sea. It searches for astrophysical neutrinos collecting the Cherenkov light induced by the charged particles, mainly muons, produced in neutrino interactions around the detector. Since at energies of $\sim$10 TeV the muon and the incident neutrino are almost collinear, it is possible to use the ANTARES detector as a neutrino telescope and identify a source of neutrinos in the sky starting from a precise reconstruction of the muon trajectory. To get this re…
Several calibration techniques have been proposed in the literature for the calibration of two-component two-dimensional (2C-2D) particle image velocimetry (PIV) and three-component two-dimensional (3C-2D) stereoscopic PIV (SPIV) systems. These techniques generally involve the use of a calibration target that is assumed to be at the exact centre of the laser sheet within the field of view (FOV), which in practice is very difficult to achieve. In 3C-2D SPIV, several methods offer different correction schemes based on the computation of a disparity map, which are aimed at correcting errors produ…
We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose the frequency deviations of the stabilization are measured precisely by means of a frequency comb. This allows to implement several calibration steps that compensate different systematic errors. The resulting frequency deviation is shown to be less than $5.7 $MHz (rms $1.6 $MHz) in the whole wavelength interval $750 - 795 $nm. Wide tuning of a stabilized laser at this exceptional precision is demonstrated.