用瑞利散射Laser光束标定望远镜阵列实验荧光探测器的光电倍增管

Calibration of Photomultiplier Tubes for the Fluorescence Detector of Telescope Array Experiment using a Rayleigh Scattered Laser Beam

Shingo Kawana, Nobuyuki Sakurai, Toshihiro Fujii, Masaki Fukushima, Naoya Inoue, John N. Matthews, Shoichi Ogio, Hiroyuki Sagawa, Akimichi Taketa, Masato Takita… 展开作者

Shingo Kawana, Nobuyuki Sakurai, Toshihiro Fujii, Masaki Fukushima, Naoya Inoue, John N. Matthews, Shoichi Ogio, Hiroyuki Sagawa, Akimichi Taketa, Masato Takita, Stan B. Thomas, Hisao Tokuno, Yoshiki Tsunesada, Shigeharu Udo, Lawrence R. Wiencke

摘要:

我们进行了光度校准的光电倍增管(PMT)和读出电子用于新的荧光探测器的望远镜阵列(TA)实验使用瑞利散射光子从脉冲氮激光束。实验装置,测量程序,校准的结果进行了说明。校准的总系统不确定度估计为7.2%。一个额外的不确定度为3.7%的引入由校准的PMT从实验室到TA实验场所的运输。

英文摘要:

We performed photometric calibration of the PhotoMultiplier Tube (PMT) and readout electronics used for the new fluorescence detectors of the Telescope Array (TA) experiment using Rayleigh scattered photons from a pulsed nitrogen laser beam. The experimental setup, measurement procedure, and results of calibration are described. The total systematic uncertainty of the calibration is estimated to be 7.2%. An additional uncertainty of 3.7% is introduced by the transport of the calibrated PMTs from the laboratory to the TA experimental site.