arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1604.08776physics.ins-dethep-ex
收藏

位置敏感硅探测器中的集成冷却通道

Integrated cooling channels in position-sensitive silicon detectors

L. Andricek, M. Boronat, J. Fuster, I. Garcia, P. Gomis, C. Marinas, J. Ninkovic, M. Perello Rosello, M. A. Villarejo, M. Vos

摘要:

我们提出了一种方法来构建一个集成的冷却电路的位置敏感的硅探测器。对样品的测试表明,非常适度的液体流非常有效地冷却器件,直到功率耗散超过10 W/cm $^2$。发现液体流动对机械性能的影响可以忽略不计。有限元模拟预测的冷却性能的精度约为10%。

英文摘要:

We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over 10~W/cm$^2$. The liquid flow is found to have a negligible impact on the mechanical performance. A finite-element simulation predicts the cooling performance to an accuracy of approximately 10~\%.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑