Development of a low-level Ar-37 calibration standard
R. M. Williams, C. E. Aalseth, T. W. Bowyer, A. R. Day, E. S. Fuller, D. A. Haas, J. C. Hayes, E. W. Hoppe, P. H. Humble, M. E. Keillor, B. D. LaFerriere, E. K.… 展开作者
R. M. Williams, C. E. Aalseth, T. W. Bowyer, A. R. Day, E. S. Fuller, D. A. Haas, J. C. Hayes, E. W. Hoppe, P. H. Humble, M. E. Keillor, B. D. LaFerriere, E. K. Mace, J. I. McIntyre, H. S. Miley, A. W. Myers, J. L. Orrell, C. T. Overman, M. E. Panisko, A. Seifert
备注:
Proceedings of the 20th International Conference on Radionuclide Metrology and its Applications 8-11 June 2015, Vienna, Austria
发表信息:
Applied Radiation and Isotopes, Volume 109, March 2016, Pages 430-434
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level Ar-37 standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level Ar-37 standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.
Characterization of High Temperature Calibration Bath through Stability and Uniformity Tests with Data Acquisition using Standard Platinum Resistance Thermometer and Precision Multimeter
Automatic Model Extraction of the Match Standard in Symmetric--Reciprocal--Match Calibration
Graz University of Technology(格拉茨工业大学);Institute of Microwave and Photonic Engineering, Graz University of Technology(格拉茨工业大学微波与光子工程研究所);Christian Doppler Laboratory for Technology-Guided Electronic Component Design and Characterization (TONI)(技术引导电子元件设计与表征基督教多普勒实验室)
Fully stabilized 25 GHz frequency comb for frequency calibration of optical spectrum analyzer
Korea Research Institute of Standards and Science (KRISS)(韩国计量科学研究院);University of Science and Technology (UST)(韩国科学技术院);Chungnam National University(忠南国立大学);Chung-Ang University(中央大学)
微波领域的一级功率标准是使用量热技术实现的,通常与所使用的测量系统相一致,即,微量热计经过适当的系统校准后,其相对精度至少在微波域(1 GHz-18 GHz)为10^-3量级。在此,我们描述了在Istituto Nazionale di Ricerca Metrologica(意大利)实现基于间接加热热电偶的同轴功率标准的校准过程。特别注意的是专门描述用于确定微量热计的损失和它们对被测量精度的影响的接近理想的热负荷。
The Choice of Line Lengths in Multiline Thru-Reflect-Line Calibration
Institute of Microwave and Photonic Engineering, Graz University of Technology(格拉茨工业大学微波与光子工程研究所);Christian Doppler Laboratory for Technology-Guided Electronic Component Design and Characterization (TONI)(技术引导电子元件设计与表征基督教多普勒实验室)