arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0708.1691physics.med-ph
收藏

PET监测He-3和C-12束的癌症治疗:使用GEANT4工具包的研究

PET monitoring of cancer therapy with He-3 and C-12 beams: a study with the GEANT4 toolkit

Igor Pshenichnov, Alexei Larionov, Igor Mishustin, Walter Greiner

摘要:

我们研究了$β^+$ -活性的空间分布产生的治疗光束的$^3$ He和$^{12}$ C离子在各种组织样材料。在基于GEANT 4工具包的重离子治疗(MCHIT)蒙特卡罗模型内进行计算。计算了$^{10,11}$ C、$^{13}$ N、$^{14,15}$ O、$^{17,18}$ F和$^{30}$ P正电子发射核的贡献,并与辐照前后的实验数据进行了比较。利用$^{12}$ C束在靶核和射弹核的碎裂反应中产生正电子发射核。这导致$β^+$ -活性曲线,其特征在于在相应的深度-剂量分布中靠近布拉格峰的显著峰。与此相反,由于靶碎裂反应中大部分正电子发射核是由$^3$ He束产生的,因此在辐照期间或辐照后不久计算的总$β^+$ -活度均匀地分布在射弹射程内。然而,我们预测还存在的$^{13}$ N,$^{14}$ O,$^{17,18}$ F创建的电荷转移反应中的低能量$^3$ He离子接近其范围的结束,在几个组织样媒体。对这两种束流的$β^+$活度分布随时间的演化进行了研究.由于$^{18}$ F核素的产生,在用$^{3}$ He离子辐照后2或3小时测量的$β^+$ -活性曲线将具有与深度-剂量分布的最大值相关的明显峰。我们发现,在浅层肿瘤的粒子治疗过程中,低能$^{3}$ He束比低能质子束具有可靠的PET监测的某些优势。在这种情况下,来自$^{17}$ F核的$β^+$活性分布的远侧边缘清楚地标记了组织中$^{3}$ He的范围。

英文摘要:

We study the spatial distributions of $β^+$-activity produced by therapeutic beams of $^3$He and $^{12}$C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit. The contributions from $^{10,11}$C, $^{13}$N, $^{14,15}$O, $^{17,18}$F and $^{30}$P positron-emitting nuclei were calculated and compared with experimental data obtained during and after irradiation. Positron emitting nuclei are created by $^{12}$C beam in fragmentation reactions of projectile and target nuclei. This leads to a $β^+$-activity profile characterised by a noticeable peak located close to the Bragg peak in the corresponding depth-dose distribution. On the contrary, as the most of positron-emitting nuclei are produced by $^3$He beam in target fragmentation reactions, the calculated total $β^+$-activity during or soon after the irradiation period is evenly distributed within the projectile range. However, we predict also the presence of $^{13}$N, $^{14}$O, $^{17,18}$F created in charge-transfer reactions by low-energy $^3$He ions close to the end of their range in several tissue-like media. The time evolution of $β^+$-activity profiles was investigated for both kinds of beams. Due to the production of $^{18}$F nuclide the $β^+$-activity profile measured 2 or 3 hours after irradiation with $^{3}$He ions will have a distinct peak correlated with the maximum of depth-dose distribution. We found certain advantages of low-energy $^{3}$He beams over low-energy proton beams for reliable PET monitoring during particle therapy of shallow located tumours. In this case the distal edge of $β^+$-activity distribution from $^{17}$F nuclei clearly marks the range of $^{3}$He in tissues.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑