We study the spatial distributions of $β^+$-activity produced by therapeutic beams of $^3$He and $^{12}$C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit. The contributions from $^{10,11}$C, $^{13}$N, $^{14,15}$O, $^{17,18}$F and $^{30}$P positron-emitting nuclei were calculated and compared with experimental data obtained during and after irradiation. Positron emitting nuclei are created by $^{12}$C beam in fragmentation reactions of projectile and target nuclei. This leads to a $β^+$-activity profile characterised by a noticeable peak located close to the Bragg peak in the corresponding depth-dose distribution. On the contrary, as the most of positron-emitting nuclei are produced by $^3$He beam in target fragmentation reactions, the calculated total $β^+$-activity during or soon after the irradiation period is evenly distributed within the projectile range. However, we predict also the presence of $^{13}$N, $^{14}$O, $^{17,18}$F created in charge-transfer reactions by low-energy $^3$He ions close to the end of their range in several tissue-like media. The time evolution of $β^+$-activity profiles was investigated for both kinds of beams. Due to the production of $^{18}$F nuclide the $β^+$-activity profile measured 2 or 3 hours after irradiation with $^{3}$He ions will have a distinct peak correlated with the maximum of depth-dose distribution. We found certain advantages of low-energy $^{3}$He beams over low-energy proton beams for reliable PET monitoring during particle therapy of shallow located tumours. In this case the distal edge of $β^+$-activity distribution from $^{17}$F nuclei clearly marks the range of $^{3}$He in tissues.
Analysis methods for in-beam PET images in proton therapy treatment verification: a comparison based on Monte Carlo simulations
背景和目的:束内正电子发射断层成像(PET)是质子治疗中可用于体内非侵入性治疗监测的模式之一。可以比较在各种治疗会话期间获得的PET分布,以便识别具有解剖学变化的区域。本工作的目的是在质子治疗验证的分次间PET图像比较的背景下测试和比较不同的分析方法。研究方法:在我们的研究中,我们使用FLUKA Monte Carlo代码和人工生成的CT扫描来模拟质子治疗过程中不同阶段的束内PET分布。我们比较了Beam-Eye-View方法、Most-Likely-Shift方法、基于体素的形态学方法和伽马评估方法,以比较治疗开始时和治疗几周后的PET图像。将结果与CT扫描进行比较。结果和结论:如果有很多统计数据可用,则三维方法(如VBM和伽马)优于二维方法(如MLS和BEV),因为这些方法允许识别具有异常活动的区域。VBM方法的缺点是需要大量的MC模拟。伽马分析的缺点是,在公差标准上不存在临床适应症。在计算时间方面,BEV和MLS方法是优选的。我们建议同时使用这四种方法,以便最好地确定活动变化的位置和原因。
Analysis of time-profiles with in-beam PET monitoring in charged particle therapy
背景资料:在带电粒子治疗中利用PET成像的治疗验证通常通过将空间分布的测量结果与蒙特卡罗(MC)预测进行比较来完成。然而,衰减曲线可以提供关于治疗和被照射组织的额外的独立信息。到目前为止,大多数研究都集中在长时间间隔上。在这里,我们调查的可靠性MC预测的空间和时间(衰变率)的轮廓照射后不久,我们展示了如何衰变率可以给出一个指示的元素,其中的幻影组成。方法和材料:在Bronowice质子治疗中心的回旋加速器中心,在临床和接近临床的条件下对各种幻影进行了辐照。使用平面16 x 16 cm $^2$ PET系统采集PET数据。用FLUKA程序模拟了粒子间的相互作用和光子在体模中的传播。分析包括实验数据和MC模拟的空间和时间分布之间的比较,以及拟合程序,以获得各种同位素的贡献在幻影。结果和结论:在一维空间和衰变率分布中,数据和MC预测之间有很好的一致性。通过用多个简单指数拟合衰变速率获得的$^{11}$ C、$^{15}$ O和$^{10}$ C的分数通常与MC预期一致。与MC中的预测值相比,我们发现数据中的$^{10}$ C略微过量,这在PE体模中尤其明显。
Nuclear fragmentation reactions in extended media studied with Geant4 toolkit
从大量的实验中可以知道,在能量超过100 A MeV的核-核碰撞中,核多重碎裂是产生中等质量碎片的主要机制。在本文中,我们调查的有效性和性能的费米分裂模型和统计多重碎片模型的Geant 4工具包的一部分。本文研究了剧烈核衰变反应对轻、中质量核束在扩展介质中传播的深度-剂量分布和次级碎片产额的影响。离子束癌症治疗和宇宙辐射屏蔽的影响进行了讨论。
Bragg-Curve Simulation of Carbon-Ion Beams for Particle-therapy Applications: a study with the GEANT4 toolkit
我们使用GEANT4 Monte Carlo MC Toolkit模拟碳离子束入射到水、组织和骨骼上,同时考虑到核碎裂反应。在增加初级射束的能量时,布拉格峰的位置转移到体模内部更深的位置。对于不同的材料,峰值位于沿束方向的较浅的深度处,并且随着电子密度NZ的增加而变得尖锐。随后,产生的深度剂量的布拉格曲线,然后基准与德国GSI的实验数据。计算结果与GSI实验数据具有较好的相关性,精度在0.02~0.08cm之间,为在重离子治疗计划中采用MC奠定了基础。Kolmogorov-Smirnov K-S检验从统计学的角度进一步确定了模拟数据与实验测量数据非常匹配。将入口处的二维等剂量线与峰值位置周围和超出峰值的尾部区域中的等剂量线进行比较,表明由于二次剂量,与水和组织相比,骨产生更多剂量。在水中,结果表明,每个碎片沉积的最大能量主要归因于次级碳离子,其次是次级硼和铍。此外,产生的质子数是最高的,从而对尾区的总剂量沉积做出最大贡献。最后分析了中子和光子的关联谱。平均中子能量值为16.29 MeV,次级γ射线为1.03 MeV。然而,中子剂量被认为是可以忽略不计的总剂量相比,由于其较长的范围。
Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
目的:在Geant4(10.7版)中开发一个用于最近发布的环形门架直线加速器的蒙特卡罗(MC)治疗剂量计算工具包,用于放射治疗计划的二次剂量验证。研究方法:对于Halcyon(Varian Medical Systems),对DSMLC进行建模,并使用Geant 4模拟DSMLC和患者体模中的辐射传输。辐射源从相空间文件中采样,用于DSMLC上方的直线加速器头。使用Varian提供的基于云的Monte Carlo(MC)模拟器VirtuaLinac(VL)获得相空间文件。不同方野宽度(2x2、4x4、6x6、8x8、10x10、20x20和28x28 cm 2)的剂量曲线,即,百分比深度剂量(PDD)曲线和横向剖面进行了模拟,并与实验剖面进行了比较。还使用开发的工具包计算了两个解剖部位(前列腺和脑)的IMRT(调强放射治疗)计划,并与TPS计算的剂量进行了比较(Acuros,Eclipse 15.6)。使用3D剂量差和3D伽马分析来评价与TPS计算剂量相比的模拟准确度。结果如下:对于所有模拟射野尺寸,水模中模拟的侧向剂量分布和PDD曲线与测量值匹配良好,相对差异为± 2%。对于前列腺和脑调强放射治疗计划,模拟剂量与TPS计算剂量显示出良好的一致性。两个前列腺和脑计划的3D伽马通过率(3%/3mm)分别为98.08%和95.4%。结论:开发的Halcyon全MC剂量计算工具包在水模体…
Terbium-149 PET/CT: First Quantitative Imaging with a Clinical Long-Axial Field-of-View Scanner
Department of Nuclear Medicine, Inselspital, Bern University Hostpital, University of Bern(伯尔尼大学医院因塞尔斯皮塔尔核医学科);ARTORG Center for Biomedical Engineering Research, University of Bern(伯尔尼大学ARTORG生物医学工程研究中心);Albert Einstein Center for Fundamental Physics (AEC), Laboratory for High Energy Physics (LHEP), University of Bern(伯尔尼大学阿尔伯特·爱因斯坦基础物理中心(AEC)高能物理实验室(LHEP));Center for Radiopharmaceutical Sciences, PSI Center for Life Sciences, Villigen-PSI(维利根-PSI PSI生命科学中心放射药学科学中心);Institut Laue-Langevin(朗之万研究所);Laboratory of Radiochemistry, PSI Center for Nuclear Engineering and Sciences(PSI核工程与科学中心放射化学实验室)
Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
Instituto de Física Corpuscular (CSIC-University of Valencia)(粒子物理研究所(西班牙科学理事会-瓦伦西亚大学));Universitat Politècnica de Catalunya(加泰罗尼亚理工大学);GSI Helmholtzzentrum für Schwerionenforschung(德国重离子研究中心);Institut für Kernphysik, Technische Universität Darmstadt(达姆施塔特工业大学核物理研究所);West German Proton Therapy Centre(西德质子治疗中心)
Weighted Directional Total Nuclear Variation for Joint Yttrium-90 PET/SPECT Reconstruction with CTAC-derived Guidance
University College London (UCL)(伦敦大学学院);The National Physical Laboratory (NPL)(英国国家物理实验室);Oxford University Hospitals NHS Foundation Trust(牛津大学医院NHS基金会信托);University of Oxford(牛津大学);The Christie NHS Trust(克里斯蒂NHS信托);Centre for Inverse Problems(逆问题中心)
First image-guided treatment of a mouse tumor with radioactive ion beams
GSI Helmholtzzentrum für Schwerionenforschung(GSI亥姆霍兹重离子研究中心);Ludwig-Maximilians-Universität München (LMU)(慕尼黑路德维希-马克西米利安大学);Technische Universität Darmstadt(达姆施塔特工业大学);Technische Hochschule Mittelhessen(黑森应用技术大学);Justus-Liebig-Universität Gießen(吉森约翰内斯·谷登堡大学);Helmholtz Research Academy Hesse for FAIR (HFHF)(黑森FAIR亥姆霍兹研究院);University Federico II(那不勒斯费德里科二世大学)