评估部分容积校正对淋巴瘤病灶FDG PET影像组学可重复性的影响
Evaluating the Impact of Partial Volume Correction on FDG PET Radiomics Reproducibility in Lymphoma Lesions
AI总结:
本研究评估部分容积校正(PVC)对淋巴瘤病灶FDG PET影像组学可重复性的影响,发现PVC可显著提升可重复性(尤其大病灶),一阶和GLCM特征稳健,为标准化影像组学及生物标志物开发提供支持,需多中心验证。
摘要:
为评估部分容积校正(PVC)如何影响淋巴瘤病灶中18F-FDG PET影像组学特征的可重复性,并分析其与病灶体积和组织类型的关系。本单中心回顾性研究纳入131例新诊断淋巴瘤患者,均接受基线18F-FDG PET/CT检查。共对1603个病灶(1302个淋巴结、117个脾/肝、150个骨、34个骨/软组织病灶)进行半自动分割,并按体积(<3、3-10、10-30、>30 mL)和组织类型分组。遵循IBSI指南,从非PVC图像及经Richardson-Lucy(RL)和Reblurred Van Cittert(RVC)算法处理的PVC图像中提取93个影像组学特征。采用变异系数(CoV)和组内相关系数(ICC2,绝对一致性)量化可重复性,通过Mann-Whitney U检验和假发现率(FDR)校正进行统计比较。PVC显著提高特征可重复性,尤其对于大病灶(>30 mL),大多数特征类别中位ICC2>0.90。小病灶(<3 mL)稳定性较低(ICC2=0.84-0.94)且CoV较高(0.09-0.21)。一阶(First-Order)和灰度共生矩阵(GLCM)特征总体最稳健(ICC2=0.92-0.99;CoV=0.07-0.11)。骨和脾病灶可重复性最高(中位ICC2约0.95),而淋巴结和肝病灶特征变异性更大。FDR校正后,所有体积和组织相关差异仍具有统计学意义(p<0.05)。使用RL和RVC的PVC显著增强淋巴瘤FDG-PET影像组学可重复性,尤其对于较大且结构均匀的病灶。一阶和GLCM等稳健特征可支持标准化影像组学工作流程,助力开发可靠的预后生物标志物和个性化治疗方案。需多中心验证以确认单中心外的普适性。
英文摘要:
To evaluate how partial volume correction (PVC) affects the reproducibility of 18F-FDG PET radiomic features in lymphoma lesions, with respect to lesion volume and tissue type. This single-center retrospective study included 131 newly diagnosed lymphoma patients who underwent baseline 18F-FDG PET/CT. In total, 1,603 lesions (1,302 lymph nodes, 117 spleen/liver, 150 bone, and 34 bone/soft-tissue) were semi-automatically segmented and grouped by volume (<3, 3-10, 10-30, >30 mL) and tissue type. 93 radiomic features were extracted from non-PVC and PVC images processed with the Richardson-Lucy (RL) and Reblurred Van Cittert (RVC) algorithms following IBSI guidelines. Reproducibility was quantified using the coefficient of variation (CoV) and the intraclass correlation coefficient (ICC2, absolute agreement), with statistical comparisons performed via Mann-Whitney U tests and false-discovery-rate (FDR) correction. PVC significantly improved feature reproducibility, particularly for large lesions (>30 mL), with median ICC2>0.90 across most feature categories. Small lesions (<3 mL) showed lower stability (ICC2=0.84-0.94) and higher CoV (0.09-0.21). First-Order and GLCM features were the most robust overall (ICC2=0.92-0.99; CoV=0.07-0.11). Bone and spleen lesions exhibited the highest reproducibility (median ICC2 approx 0.95), whereas lymph-node and liver features were more variable. All volume- and tissue-dependent differences remained significant after FDR correction (p<0.05). PVC using RL and RVC markedly enhances FDG-PET radiomic reproducibility in lymphoma, particularly for larger and structurally uniform lesions. Robust features such as First-Order and GLCM can support standardized radiomics workflows and the development of reliable biomarkers for prognosis and personalized therapy. Multicenter validation is warranted to confirm generalizability beyond a single-center setting.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。