arXivDaily arXiv每日学术速递 周一至周五更新
arXiv physics/9906017physics.ins-dethep-exphysics.gen-ph
收藏

用声子和闪烁光的同时探测鉴别核粒子和电子粒子

Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light

P. Meunier, M. Bravin, M. Bruckmayer, S. Giordano, M. Loidl, O. Meier, F. Proebst, W. Seidel, M. Sisti, L. Stodolsky, S. Uchaikin, L. Zerle

摘要:

我们研制了一个探测器,它由一个以闪烁晶体为吸收体的低温量热计和一个用于探测闪烁光的第二量热计组成,两者都工作在12 mK。用质量为6g的CaWO_4晶体作吸收体,在15keV以上的能量范围内,实现了对核反冲和电子反冲的区分,抑制因子为99.7%。这种新的方法将被应用于CRESST(低温稀有事件搜索与超导温度计)实验寻找暗物质弱相互作用大质量粒子(WIMPs)的背景拒绝。

英文摘要:

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies above 15 keV. This novel method will be applied for background rejection in the CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) experiment looking for dark matter Weakly Interacting Massive Particles (WIMPs).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑