基于纯闪烁的液态氙中核粒子和电子粒子的脉冲形状鉴别

Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon

K. Ueshima, K. Abe, K. Hiraide, S. Hirano, Y. Kishimoto, K. Kobayashi, Y. Koshio, J. Liu, K. Martens, S. Moriyama, M. Nakahata, H. Nishiie, H. Ogawa, H. Sekiya,… 展开作者

K. Ueshima, K. Abe, K. Hiraide, S. Hirano, Y. Kishimoto, K. Kobayashi, Y. Koshio, J. Liu, K. Martens, S. Moriyama, M. Nakahata, H. Nishiie, H. Ogawa, H. Sekiya, A. Shinozaki, Y. Suzuki, A. Takeda, M. Yamashita, K. Fujii, I. Murayama, S. Nakamura, K. Otsuka, Y. Takeuchi, Y. Fukuda, K. Nishijima, D. Motoki, Y. Itow, K. Masuda, Y. Nishitani, H. Uchida, S. Tasaka, H. Ohsumi, Y. D. Kim, Y. H. Kim, K. B. Lee, M. K. Lee, J. S. Lee the XMASS Collaboration

摘要:

在一个专门的测试设置在神冈天文台,我们研究了脉冲形状歧视(PSD)在液体氙(LXe)的暗物质搜索。PSD在LC 10是基于观察到的闪烁光从电子事件发射的时间比核反冲事件,我们的方法使用了一个简单的比率早期总闪烁光发射在一个单一的闪烁事件。需要50%的核反冲保留效率,我们将能量在4.8和7.2 keVee之间的电子背景降低到7.7 \pm 1.1(stat)\pm 1.2 0.6(sys)\times 10-2,并将能量在4.8和7.2 keVee之间的电子背景降低到7.7 \pm 2.8(stat)\pm 2.5 2.8(sys)\times 10- 2。3,能量在9.6至12 keVee之间,闪烁光产量为20.9 p.e./凯通过掩蔽一些光以将该产率降低至4.6p.e./ keV,相同的方法导致电子事件减少2.4 \pm 0.2(stat)\pm 0.3 0.2(sys)\times 10-1以上较低的能量区域。我们还观察到,在对比核反冲的波动,我们的早期电子事件的总比率大于预期的统计波动。

英文摘要:

In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑