The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19+-0.02.
Polytetrafluoroethylene (PTFE), also known as Teflon, is a common material used in the construction of liquid xenon detectors due to its high reflectivity for the VUV scintillation light of xenon. We present transmission measurements of PTFE for xenon scintillation light with peak emission at a wavelength of 175 nm. PTFE discs of different thicknesses are installed in front of a photosensor in two setups. One is filled with gaseous xenon, the other with liquid xenon. The measurements performed with the gaseous xenon setup at room temperature yield a transmission coefficient of $λ= \bigl(350{{}…
First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less then 1 ns (FWHM) were measured with 5.5 MeV alpha-particles and 511 keV gamma-rays, respectively. The quantum efficiency of the photodiode for xenon scintillation light (wavelength 178 nm) is estimated to be ~100%.
Proportional scintillation in liquid xenon has a promising application in the field of direct dark matter detection, potentially allowing for simpler, more sensitive detectors. However, knowledge of the basic properties of the phenomenon as well as guidelines for its practical use are currently limited. We report here on measurements of proportional scintillation light emitted in liquid xenon around thin wires. The maximum proportional scintillation gain of $287^{+97}_{-75}$ photons per drift electron was obtained using 10 $μ$m diameter gold plated tungsten wire. The thresholds for electron mu…
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that…
Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet wavelength region (175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work we report on measurements of PTFE reflectance, including its angular distribution, for the xenon …
Understanding liquid xenon scintillation and ionization processes is of great interest to improve analysis methods in current and future detectors. In this paper, we investigate the dynamics of the scintillation process for excitation by $\mathcal{O}$(10 keV) electrons from a $^{83m}$Kr source and $\mathcal{O}$(6 MeV) $α$-particles from a $^{222}$Rn source, both mixed with the xenon target. The single photon sampling method is used to record photon arrival times in order to obtain the corresponding time distributions for different applied electric fields between about 0.8 V/cm to 1.2 kV/cm. En…
Xenon-doped liquid argon has been proposed as a good alternative to pure liquid argon in scintillation detectors. In this study, we report on the measurement of the time profile of scintillation light emitted from xenon-doped liquid argon with molar concentrations up to 1600 ppm. A compact setup has been developed for this study, with silicon photomultiplier (SiPM) as the photosensor and $^{210}\mathrm{Po}$ and $^{90}\mathrm{Sr}$ as scintillation sources. An effective model based on the de-excitation processes has been developed to describe the data. The results show that xenon-doped liquid ar…
We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in detail, and a new waveform model is established and used to fit the average waveform. The time profile of the scintillation photon in the xenon-doped liquid argon and of the TPB emission are presented. The quantities of xenon-doped are controlled by a Mass Flow Controller which is calibrated via a Redusial Gas Analyzer to ensure that the xenon concentration is ac…
Scintillation produced in liquid xenon by alpha particles and gamma rays has been studied as a function of applied electric field. For back scattered gamma rays with energy of about 200 keV, the number of scintillation photons was found to decrease by 64+/-2% with increasing field strength. Consequently, the pulse shape discrimination power between alpha particles and gamma rays is found to reduce with increasing field, but remaining non-zero at higher fields.
The attenuation length and refractive index of liquid xenon for intrinsic scintillation light (178nm) have been measured in a single experiment. The value obtained for attenuation length is 364 +- 18 mm. The refractive index is found to be 1.69 +- 0.02. Both values were measured at a temperature of 170 +- 1 K.
The use of xenon-doped liquid argon is a promising alternative for large pure liquid-argon TPCs. Not only xenon-doped liquid argon enhances the light production, mitigating the possible suppression due to impurities, but also it increases the wavelength of the scintillation light, enlarging the effective Rayleigh scattering length and improving the detection uniformity. ProtoDUNE Dual-Phase is a 300-ton active volume LAr TPC, a prototype for the Deep Underground Neutrino Experiment (DUNE), a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon …
The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as a reference for the determination of the number of charge carriers produced by the scintillation pulse and, thus, the number of VUV photons impinging the photodiode. A value of 140 photons/kV was obtai…
The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 deg. was measured to be 0.64 +/- 0.02 (stat.) +/- 0.06 (sys.) of that at -100 deg. Using the reported light yield at -100 deg. (46 photons/keV), the measured light yield at 1 deg. corresponds to 29 photons/keV. This result shows that liquid xenon scintillator gives high light yield even at room temperature.
We perform a theoretical study of the scintillation efficiency in the low-energy region crucial for liquid-xenon dark-matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid xenon and calculate the nuclear quenching effect due to atomic collisions. We use the electronic stopping power extrapolated from the experimental data to the low-energy region, and take into account the effects of electrons escaping from the electron-ion pair recombination using the generalized Thomas-Imel model fitted to scintillation data. Our result agr…
We present a systematic study of the time and band-resolved scintillation in xenon-based time projection chambers (TPCs), performed simultaneously for the primary (S1) and secondary (S2) components in a small, purity-controlled, setup. We explore a range of conditions of general academic interest, focusing on those of relevance to contemporary TPCs: pressure range ([1- 10] bar), pressure-reduced electric fields ([0-100] V/cm/bar in the drift region (S1) and up to the proportional scintillation regime in the multiplication region (S2)), wavelength-band ([145-250], [250-400], [400-600] nm), and …
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (…
In order to assess the performance of liquid xenon detectors for use in positron emission tomography we studied the scintillation light and ionization charge produced by 511 keV photons in a small prototype detector. Scintillation light was detected with large area avalanche photodiodes while ionization electrons were collected on an anode instrumented with low noise electronics after drifting up to 3 cm. Operational conditions were studied as a function of the electric field. Energy resolutions of <10 % (FWHM) were achieved by combining the scintillation light and ionization charge signals. T…
We present a detector apparatus, DireXeno (DIRectinal Xenon), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments, however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits correlation in light emission such as super-radiance, which depends on the type of interaction. Such properties of scintillation light may open a new window …
The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~$μ$s after de-excitation emission, scintillation photons are separated to the fast and slow components. The fast component does not show dependence on the track angle relative to the drift electric field, on the other…
Liquid xenon has several attractive features, which make it suitable for applications to nuclear medicine, such as high scintillation yield and fast scintillation decay time, better than currently used crystals. Since the '90s, several attempts has been made to build Positron Emission Tomography scanners based on liquid xenon, which can be divided into two different approaches: on one hand, the detection of the ionization charge in TPCs, and, on the other one, the detection of scintillation light with photomultipliers. PETALO (Positron Emission Tof Apparatus with Liquid xenOn) is a novel conce…
Liquid argon (LAr) is a common choice as detection medium in particle physics and rare-event searches. Challenges of LAr scintillation light detection include its short emission wavelength, long scintillation time and short attenuation length. The addition of small amounts of xenon to LAr is known to improve the scintillation and optical properties. We present a characterization campaign on xenon-doped liquid argon (XeDLAr) with target xenon concentrations ranging from 0 to 300 ppm by mass encompassing the measurement of the photoelectron yield $Y$ , effective triplet lifetime $τ_3$ and effect…
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm, using a three-dimensional sensitive liquid xenon time projection chamber with high energy and position resolutions. Our measurement of signal responses to nuclear recoils agrees with predictions from the NEST model. However, our measured ionization (scintillation) yields for electronic recoils are consistently higher (lower) than those from the NEST model by ab…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for max…
We present measurements of the scintillation pulse shape in liquid xenon for nuclear recoils (NR) and electronic recoils (ER) at electric fields of 0 to 0.5 kV/cm for energies $<$ 15 keV and $<$ 70 keV electron-equivalent, respectively. The average pulse shapes are well-described by an effective model with two exponential decay components, where both decay times are fit parameters. We find significant broadening of the pulse for ER due to delayed luminescence from the recombination process. In addition to the effective model, we fit a model describing the recombination luminescence for ER at z…
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We rep…
A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O(1 keV) to O(1 MeV) and electric fields between 0 and O(10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, im…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. The measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted $γ$ cascades can provide the nuclei with up to $0.3$ keV$_\text{nr}$ of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below…
Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where $\sim 10 - 1000$ ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fu…
An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an ab…
The operational characteristics of a Micromegas operating in pure xenon at the pressure range of 1 to 10 bar are investigated. The maximum charge gain achieved in each pressure is approximately constant, around 4x10^2, for xenon pressures up to 5 bar and decreasing slowly above this pressure down to values somewhat above 10^2 at 10 bar. The MM presents the highest gains for xenon pressures above 4 bar, when compared to other micropattern gaseous multipliers. The lowest energy resolution obtained for X-rays of 22.1 keV exhibits a steady increase with pressure, from 12% at 1bar to about 32% at 1…
We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241 alpha source. The gain of the SiPM at this temperature was estimated to be 1.8 x 10^6 with bias voltage at 52 V. Based on the geometry of the setup, the quantum efficiency of the SiPM was estimated to be 22% at the Xe wavelength of 178 nm. The low excess noise factor, high single photoelectron detection efficiency, and low bias voltage of SiPMs make them attractive…
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric …
We present a measurement of scintillation efficiency for a few tens of keV nuclear recoils (NR) with a liquid argon time projection chamber under electric fields ranging from $0$ to $3\ {\rm kV/cm}$. The calibration data are taken with $^{252}{\rm Cf}$ radioactive source. Observed scintillation and electroluminescence spectra are simultaneously fit with spectra derived from Geant4-based Monte Carlo simulation and an NR model. The scintillation efficiency extracted from the fit is reported as a function of recoil energy and electric field. This result can be used for designing the detector and …
Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded io…
Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the d…
A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from …
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below $0.3$ keV$_\text{NR}$ via the asymmetric emission of $γ$ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimi…
The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field dependence at recoil energies less than 10 keV. In this paper we present results of such measurements using a specialized detector. Recoil energies are determined via the Compton coincidence technique at four drift fields relevant for liquid xenon dark matter detectors: 0.19, 0.48, 1.02, and 2.32 kV/cm. Mean recoil energies down to 1 keV were measured with u…
The ionization yield in the two-phase liquid xenon dark-matter detector has been studied in keV nuclear-recoil energy region. The newly-obtained nuclear quenching as well as the recently-measured average energy required to produce an electron-ion pair are used to calculate the total electric charges produced. To estimate the fraction of the electron charges collected, the Thomas-Imel model is generalized to describing the field dependence for nuclear recoils in liquid xenon. With free parameters fitted to experiment measured 56.5 keV nuclear recoils, the energy dependence of ionization yield f…
Measurement of the scintillation resolution in liquid xenon and its impact for future segmented calorimeters
Los Alamos National Laboratory(洛斯阿拉莫斯国家实验室);Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València(粒子物理研究所(IFIC),西班牙科学委员会与瓦伦西亚大学);Donostia International Physics Center, BERC Basque Excellence Research Centre(多诺西亚国际物理中心,巴斯克卓越研究中心);Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València(分子成像仪器研究所(I3M),西班牙科学委员会-巴伦西亚理工大学混合中心);Instituto Universitario de Matemática Pura y Aplicada (IUMPA), Universitat Politècnica de València(纯数学与应用数学大学研究所(IUMPA),巴伦西亚理工大学)
We present the precision calibration of 35 Hamamatsu R11410-22 photomultiplier tubes (PMTs) with xenon scintillation light centred near 175 nm. This particular PMT variant was developed specifically for the LUX-ZEPLIN (LZ) dark matter experiment. A room-temperature xenon scintillation cell coupled to a vacuum cryostat was used to study the full-face PMT response at both room and low temperature $\textrm{($\sim$ -100$^\circ$C)}$, in particular to determine the quantum efficiency (QE) and double photoelectron emission (DPE) probability in LZ operating conditions. For our sample with an average Q…
We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. …
As liquid xenon TPCs increase in target mass while pursuing the direct detection of WIMP dark matter, the technical challenges arising due to their size call for new solutions and open the discussion on alternative detector concepts. Proportional scintillation in liquid xenon allows for a single-phase design evading all problems related to the liquid-gas interface and the precise gas gap required in a dual-phase TPC. Aside from a different scintillation mechanism, the successful detection- and analysis scheme of state-of-the-art experiments is maintained in this approach. We study the impact o…
A two-phase argon detector has high discrimination power between electron recoil and nuclear recoil events based on the pulse shape discrimination and the ionization/scintillation ratio (S2/S1). This character is very suitable for the dark matter search to establish the low background experiment. However, the basic properties of S2/S1 of argon are not well known, as compared with xenon. We report the evaluation of S2/S1 properties with a two-phase detector at drift-fields of 0.2-3.0 kV/cm. Finally, the discrimination power against electron recoil background of S2/S1 is discussed.
The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axion-like particles, as opposed to weakly interacting massive particles which are predicted to scatter with atomic nuclei. Recently, liquid-xenon scintillation light has been observed from electronic recoils down to 2.1 keV, but without applied electric fields that are used in most xenon dark matter searches. Applied electric fields can reduce the scintillation yield by hindering the electron-ion …
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this energy regime a correct treatment of the detector threshold and resolution remains unclear. The energy dependence of the scintillation yield of liquid xenon for nuclear recoils also bears heavily on detector sensitivity, yet numerous measurements have not succeeded in obtaining concordant results. In this article we show that the ratio of detected ionization…
The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that surround the active volume. To improve the light collection in such detectors the active volume is usually surrounded by polytetrafluoroethylene (PTFE) reflector panels, used due to its very high reflectance -- even at the short wavelength of scintillation light of LXe (peaked at $178\,\text{nm}$). In this work, which contributed to the overall R\&D effort towards …
The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with gamma-rays indicate a high VUV light collection efficiency resulting in ~5.5 photoelectrons per 1 keV of deposited energy. The energy resolution (FWHM) is 18% and 22%, for 122 keV and 511 keV gamma-rays, respectively. An algorithm for the reconstruction of the scintillation coordinates in (x,y) plane was developed and tested. The position resolution is estimated…
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies above 15 keV. This novel method will be applied for background rejection in the CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) experiment looking for dark matter Weakly Interactin…
Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by th…
We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median ap…
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.