摘要:

建立了一个基于VME的电荷比较法n-γ鉴别实验系统。利用LabVIEW开发了数据采集程序,通过VME 64 X总线实现对可编程模块的控制和数据的在线处理。给出了Am-Be中子源和Cf中子源记录脉冲的慢分量电荷与总电荷的二维散点图。同时给出了脉冲能量与慢分量电荷占总电荷比例的二维散点图。用优值法检验了n-γ分辨的质量,结果表明在低能区n-γ分辨性能良好。中子和γ射线在50 keVee(电子当量能量)以上分离。在150、250、350、450、550 keVee五个能区,n-γ分辨的质量比其他人的结果有了提高。

英文摘要:

A VME-based experiment system for n-γ discrimination using the charge comparison method was established. A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of LabVIEW. The two-dimensional (2D) scatter plots of the charge in the slow component vs. the total charge of recorded pulses from Am-Be and Cf neutron sources were presented. The 2D scatter plots of the energy vs. the ratio of the charge in the slow component to the total charge of the pulses were presented at the meantime. The quality of n-γ discrimination was checked by the figure-of-merit, and the results showed good performance of n-γ discrimination at low energy range. Neutrons and γ-rays were separated above 50 keVee (electron-equivalent energy). The quality of n-γ discrimination have been improved compared with others' results at 5 energies (150, 250, 350, 450, 550 keVee).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑