A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.
The first eight years of operation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge is being reviewed. The instrument has been part of the facility user program since 2009, and more than 250 individual user experiments have been performed to date. CNCS is an extremely powerful and versatile instrument and offers leading edge performance in terms of beam intensity, energy resolution, and flexibility to trade one for another. Experiments are being routinely performed with the sample at extreme conditions: T~0.05K, p>=2GPa and B=8T can be achieved indi…
Many types of neutron spectrometer use a conventional primary spectrometer consisting of some collimator, a crystal monochromator and a second collimator. Conventional resolution descriptions use instrument parameter values to deduce the beam character and thence the instrument transmission and resolution. This article solves the inverse problem of choosing beam elements to deliver some desired beam character and shows that there are many possible choices of elements to deliver any given beam character. Dealing with this multiplicity seems to be a central issue in the search for optimal instru…
Bonner Spheres have been used widely for the measurement of neutron spectra with neutron energies ranged from thermal up to at least 20 MeV. A Bonner Sphere neutron spectrometer (BSS) was developed by extending a Berthold LB 6411 neutron-dose-rate meter. The BSS consists of a $^{3}$He thermal-neutron detector with integrated electronics, a set of eight polyethylene spherical shells and two optional lead shells of various sizes. The response matrix of the BSS was calculated with GEANT4 Monte Carlo simulation. The BSS had a calibration uncertainty of $\pm 8.6\%$ and a detector background rate of…
The exact resolution function in transfer vector for the reflectometer HERMÈS at Laboratoire Léon Brillouin is calculated as an example of neutron time-of-fligh spectrometer with double-disk chopper. Calculation accounts for wavelength distribution of the incident beam, tilt of the chopper axis, collimation and gravity, without approximation of gaussian distributions or independence of these different contributions. Numerical implementation is provided that matches the sections of the paper. We show that data fitting using this exact resolution function allows us to reach much better results t…
SIKA, a high-flux cold-neutron triple-axis spectrometer at the OPAL reactor at the Australian Nuclear Science and Technology Organization, is equipped with a 13-blade analyser and position-sensitive detector. This multiplexing design endows SIKA high flexibility to run in both traditional triple-axis and multiplexing analyser modes. In this study, two different multiplexing modes on SIKA are simulated using Monte-Carlo ray-tracing methods. The simulation results demonstrate SIKA capabilities to work in these operational modes, especially, the multi-Q const-Ef mode. This capability was demonstr…
MIDAS is a miniature detector developed with purpose to assess the radiation field parameters near to an astronaut. Part of the device is a spectrometer for fast neutrons. In missions outside the geomagnetic field, fast neutrons are secondary products of the interaction of Galactic Cosmic Ray heavy ions with the materials in the spaceship or even the astronaut body. The Relative Biological Effectiveness of fast neutrons is high. The neutron spectrometer first prototype has been developed, calibrated and used for measuring 252Cf spectra.
The RESEDA (Resonant Spin-Echo for Diverse Applications) instrument has been optimized for neutron scattering measurements of quasi-elastic and inelastic processes over a wide parameter range. One spectrometer arm of RESEDA is configured for the MIEZE (Modulation of Intensity with Zero Effort) technique, where the measured signal is an oscillation in neutron intensity over time prepared by two precisely tuned radio-frequency (RF) flippers. With MIEZE, all spin-manipulations are performed before the beam reaches the sample, and thus the signal from sample scattering is not disrupted by any depo…
A high power pulsed laser system has been installed on the high magnetic field muon spectrometer (HiFi) at the ISIS pulsed neutron and muon source, situated at the STFC Rutherford Appleton Laboratory in the UK. The upgrade enables one to perform light-pump muon-probe experiments under a high magnetic field, which opens new applications of muon spin spectroscopy. In this report we give an overview of the principle of the HiFi Laser system, and describe the newly developed techniques and devices that enable precisely controlled photoexcitation of samples in the muon instrument. A demonstration e…
We propose the design of a Resonance SPin-echo spECtrometer for exTreme studies, RESPECT, that is ideally suited for the exploration of non-dispersive processes such as diffusion, crystallization, slow dynamics, tunneling processes, crystal electric field excitations, and spin fluctuations. It is a variant of the conventional neutron spin-echo technique (NSE) by i) replacing the long precession coils by pairs of longitudinal neutron spin-echo coils combined with RF-spin flippers and ii) by stabilizing the neutron polarization with small longitudinal guide fields that can in addition be used as…
There is currently a big effort put into the operation and construction of world class neutron scattering facilities (SNS and SNS-TS2 in the US, J-PARC in Japan, ESS in Europe, CSS in China, PIK in Russia). On the other hand, there exists a network of smaller neutron scattering facilities which play a key role in creating a large neutron scattering community who is able to efficiently use the existing facilities. With the foreseen closure of the ageing nuclear research reactors, especially in Europe there is a risk of seeing a shrinking of the community who would then be able to use efficientl…
SPHERES, Jülich's High-Flux Neutron Backscattering Spectrometer at FRM II
SPHERES(SPectrometer with High Energy RESolution)是第三代中子背散射谱仪,位于德国20 MW中子源FRM II,由Juelich中子科学中心运营。它的能量分辨率(fwhm)优于0.65 micro-eV,动态范围为+-31 micro-eV,信噪比高达1750:1。
The MAPS direct geometry time-of-flight chopper spectrometer at the ISIS pulsed neutron and muon source has been in operation since 1999 and its novel use of a large array of position-sensitive neutron detectors paved the way for a later generations of chopper spectrometers around the world. Almost two decades of experience of user operations on MAPS, together with lessons learned from the operation of new generation instruments, led to a decision to perform three parallel upgrades to the instrument. These were to replace the primary beamline collimation with supermirror neutron guides, to ins…
In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer, the Mimac-FastN detector, having a very large neutron energy range (10 keV - 600 MeV) with different gas mixtures and pressures. The present paper shows its main features and functionality and demonst…
Neutron and gamma-ray spectroscopy (NGRS) is a well established technique for studying the geochemical composition and volatile abundance relevant to planetary structure and evolution of planetary bodies. Previous NGRS instruments have used separate gamma-ray and neutron spectrometers. The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) instrument is an innovative and fully integrated NGRS with low resource requirements. EPICS utilizes elpasolite scintillator read out by silicon photomultipliers to combine the gamma-ray and neutron spectrometer into a single instrument, leading t…
The European Spallation Source (ESS) is intended to become the most powerful spallation neutron source in the world and the flagship of neutron science in the upcoming decades. The exceptionally high neutron flux will provide unique opportunities for scientific experiments, but also set high requirements for the detectors. One of the most challenging aspects is the rate capability and in particular the peak instantaneous rate capability, i.e. the number of neutrons hitting the detector per channel or cm$^2$ at the peak of the neutron pulse. The primary purpose of this paper is to estimate the …
A new muon source has been proposed to conduct muon spin rotation/relaxation/resonance ($μ$SR) measurements at China Spallation Neutron Source (CSNS). Only 1 Hz of the CSNS proton beams (25 Hz in total) will be allocated for muon production. To make better use of muons in every pulse, an ultrahigh-array $μ$SR spectrometer (UHAM) with thousands of detector channels is under design. Due to such a high granularity of detectors, multiple counting events generated from particle scattering or spiral motions of positrons in a strong longitudinal field should be carefully considered in the design. Six…
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2, 100 um thick single crystal CVD commercial diamond plates. The measurements were performed in the fission spectrum domain at five different neutron energies varying from 0.3 up to 2 MeV. The obtaine…
The elastic energy resolution, integrated intensity, and peak intensity of the direct-geometry neutron chopper spectrometer 4SEASONS at Japan Proton Accelerator Research Complex (J-PARC) were re-investigated. This was done with respect to the incident energy and the rotation speed of the Fermi chopper using incoherent scattering of vanadium and simple analytical formulas. The model calculations reproduced the observed values satisfactorily. The present work should be useful for estimating in instrument performance in experiments.
Results for the response function determination of the Compact Neutron Spectrometer
紧凑型中子谱仪(CNS)是一个联合欧洲环(JET)增强项目,设计用于不同等离子体场景下的聚变诊断。CNS基于液体闪烁体(BC 501 A),可以很好地区分中子和伽马辐射。使用BC 501 A谱仪进行中子能谱测量需要使用可靠的、完全表征的探测器。响应矩阵的测定在联邦物理技术研究所(PTB)的离子加速器设施(PIAF)进行。该设施提供了几个单能束(2.5,8,10,12和14 MeV)和一个“白场”(Emax ~17 MeV),这使得光谱仪在感兴趣的区域(从~1.5 MeV到~17 MeV)的全面表征成为可能。入射中子的能量由飞行时间方法(TOF)确定,时间分辨率为1 ns。为了检查响应矩阵,测量的脉冲高度谱展开与代码MAXED和由此产生的能量分布从TOF得到的那些进行了比较。CNS项目需要修改PTB BC 501 A光谱仪的设计,用Ente per le Nuove tecnologie,l 'Energia e l' Ambiente '(ENEA)开发的数字系统取代模拟数据采集系统(NIM模块)。使用专门为此项目开发的新软件对新数字系统的结果进行了评估。
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of signal at detector side was implemented to improve the resolution. This preamplification is based on RF transformer not sensitive to h…
The neutron background spectrum from thermal neutron to 20 MeV fast neutron was measured at the first experimental hall of China Jinping underground laboratory with a Bonner multi-sphere spectrometer. The measurement system was validated by a Cf252 source and inconformity was corrected. Due to micro charge discharge, the dataset was screened and background from the steel of the detectors was estimated by MC simulation. Based on genetic algorithm we obtained the energy distribution of the neutron and the total flux of neutron was (2.69 +/-1.02) *10^-5 cm^-2s^-1
The use of Thin-foil proton recoil (TPR) spectrometers to measure neutrons from Deuterium-Tritium (DT) fusion plasma has been studied previously and is a well established technique for neutron spectrometry. The study presented here focuses on the optimisation of the TPR spectrometer configurations consisting of dE and E silicon detectors. In addition an investigation of the spectrometer's ability to determine fuel ion temperature and fuel ion density ratio in ITER like DT plasmas has been performed. A Python code was developed for the purpose of calculating detection efficiency and energy reso…
The instrumental layout and technical realisation of the neutron resonant spin echo (NRSE) spectrometer RESEDA at the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching, Germany, is presented. RESEDA is based on a longitudinal field configuration, boosting both dynamic range and maximum resolution of the spectrometer compared to the conventional transverse layout. The resonant neutron spin echo technique enables the realisation of two complementary implementations: A longitudinal NRSE (LNRSE) option comparable to the classical neutron spin echo (NSE) method for highest energy resolution and large …
The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is a…
A self-adaptive differential evolution neutron spectrum unfolding algorithm (SDENUA) was established in this paper to unfold the neutron spectra obtained from a Water-pumping-injection Multi-layered concentric sphere Neutron Spectrometer (WMNS). Specifically, the neutron fluence bounds were estimated to accelerate the algorithm convergence, the minimum error between the optimal solution and the input neutron counts with relative uncertainties was limited to 10-6 to avoid useless calculation. Furthermore, the crossover probability and scaling factor were controlled self-adaptively. FLUKA Monte …
General Fusion is building the Fusion Demonstration Plant to demonstrate a magnetized target fusion scheme in which a deuterium plasma is heated from 200 eV to 10 keV by piston-driven compression of a liquid-lithium liner. The multilayer coaxial time-of-flight (MCTOF) neutron emission spectrometer is designed to measure the ion temperature near peak compression at which time the neutron yield will approach $10^{18}$ neutrons/s. The neutron energy distribution is expected to be Gaussian since the machine uses no neutral beam or radiofrequency heating. In this case, analysis shows that as few as…
Inelastic neutron scattering at high momentum transfers (i.e. $Q\ge20$ Å) or DINS provides direct observation of the momentum distribution of light atoms, making it a powerful probe for studying single-particle motions in liquids and solids. The quantitative analysis of DINS data requires an accurate knowledge of the instrument resolution function $R_{i}({Q},E)$ at each $Q$ and energy transfer $E$, where the label $i$ indicates whether the resolution was experimentally observed $i={obs}$ or simulated $i=sim$. Here, we describe two independent methods for determining the total resolution functi…