The exact resolution function in transfer vector for the reflectometer HERMÈS at Laboratoire Léon Brillouin is calculated as an example of neutron time-of-fligh spectrometer with double-disk chopper. Calculation accounts for wavelength distribution of the incident beam, tilt of the chopper axis, collimation and gravity, without approximation of gaussian distributions or independence of these different contributions. Numerical implementation is provided that matches the sections of the paper. We show that data fitting using this exact resolution function allows us to reach much better results than its usual approximation by a gaussian profile.
We performed simulations of the resolution function of the 4SEASONS spectrometer at J-PARC by using the Monte Carlo simulation package McStas. The simulations showed reasonably good agreement with analytical calculations of energy and momentum resolutions by using a simplified description. We implemented new functionalities in Utsusemi, the standard data analysis tool used in 4SEASONS, to enable visualization of the simulated resolution function and predict its shape for specific experimental configurations.
The calculation of neutron reflectivity from raw time-of-flight data including instrumental corrections as well as improved resolution calculation is presented. The theoretical calculations are compared to experimental data measured on the vertical sample plane reflectometer D17 and the horizontal sample plane reflectometer FIGARO at the Institut Laue-Langevin, Grenoble, France (ILL). This article comprises the mathematical body of the time-of-flight reflectivity data reduction software COSMOS which is used on D17 and FIGARO.
VOR, the versatile optimal resolution chopper spectrometer, is designed to probe dynamic phenomena that are currently inaccessible for inelastic neutron scattering due to flux limitations. VOR is a short instrument by the standards of the European Spallation Source (ESS), 30.2 m moderator to sample, and provides instantaneous access to a broad dynamic range, 1 - 120 meV within each ESS period. The short instrument length combined with the long ESS pulse width enables a quadratic flux increase, even at longer wavelengths, by relaxing energy resolution from $Δ$E/E = 1% up to $Δ$E/E = 7%. This is…
The first eight years of operation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge is being reviewed. The instrument has been part of the facility user program since 2009, and more than 250 individual user experiments have been performed to date. CNCS is an extremely powerful and versatile instrument and offers leading edge performance in terms of beam intensity, energy resolution, and flexibility to trade one for another. Experiments are being routinely performed with the sample at extreme conditions: T~0.05K, p>=2GPa and B=8T can be achieved indi…
CSPEC is the cold chopper spectrometer of the European Spallation Source (ESS) and will come on-line with the ESS beam on target. CSPEC will be the first cold chopper spectrometer on a long pulsed spallation source which provides great opportunities in terms of signal to noise and novel measuring schemes. We provide a detailed overview of the instrument, scientific design considerations and engineering requirements.
The MAPS direct geometry time-of-flight chopper spectrometer at the ISIS pulsed neutron and muon source has been in operation since 1999 and its novel use of a large array of position-sensitive neutron detectors paved the way for a later generations of chopper spectrometers around the world. Almost two decades of experience of user operations on MAPS, together with lessons learned from the operation of new generation instruments, led to a decision to perform three parallel upgrades to the instrument. These were to replace the primary beamline collimation with supermirror neutron guides, to ins…
The design and performance of the new Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct geometry inelastic time-of-flight spectrometer, designed to cover essentially the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM2, AMATERAS at J-PARC, PHAROS at LANSCE and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good ag…
Inelastic neutron scattering at high momentum transfers (i.e. $Q\ge20$ Å) or DINS provides direct observation of the momentum distribution of light atoms, making it a powerful probe for studying single-particle motions in liquids and solids. The quantitative analysis of DINS data requires an accurate knowledge of the instrument resolution function $R_{i}({Q},E)$ at each $Q$ and energy transfer $E$, where the label $i$ indicates whether the resolution was experimentally observed $i={obs}$ or simulated $i=sim$. Here, we describe two independent methods for determining the total resolution functi…
The elastic energy resolution, integrated intensity, and peak intensity of the direct-geometry neutron chopper spectrometer 4SEASONS at Japan Proton Accelerator Research Complex (J-PARC) were re-investigated. This was done with respect to the incident energy and the rotation speed of the Fermi chopper using incoherent scattering of vanadium and simple analytical formulas. The model calculations reproduced the observed values satisfactorily. The present work should be useful for estimating in instrument performance in experiments.
Evaluation of a method for time-of-flight, wavelength and distance calibration for neutron scattering instruments by means of a mini-chopper and standard neutron monitors
Neutron correlation spectroscopy can exceed direct spectroscopy in the incoming beam intensity by up to two orders of magnitude at the same energy resolution. However, the propagation of the counting noise in the correlation algorithm of data reduction is disadvantageous for the lowest intensity parts of the observed spectrum. To mitigate this effect at pulsed neutron sources we propose two dimensional time-of-flight recording of each neutron detection event: with respect to both the neutron source pulses and to the rotation phase of the pseudo-random beam modulation statistical chopper. We ha…
The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demonstrator has an active area of 0.2 m$^2$. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering …
An analytical method is presented with allows to estimate the energy resolution of time-of-flight neutron spectrometers, as well as its partial contributions, over a dynamical range that extends from the elastic line to the accessible inelastic regions. Such a method, already successfully applied in the past to the TOSCA and HET neutron inelastic scattering spectrometers installed at the ISIS neutron spallation source [A M Gaspar, PhD Thesis, Universidade Tecnica de Lisboa, 2004], is here applied to the high resolution time-of-flight spectrometer TOFTOF, mainly dedicated to quasi-elastic neutr…
Etched multilayers obtained by forming a laminar grating pattern within interferential multilayer mirrors are used in the soft x-ray range to improve the spectral resolution of wavelength dispersive spectrometers equipped with periodic multilayers. We describe the fabrication process of such an etched multilayer dispersive element, its characterization through reflectivity measurement and simulations, and its implementation in a high-resolution Johann-type spectrometer. The specially designed patterning of a Mo/B4C multilayer is found fruitful in the range of the C K emission as the diffractio…
We describe a spin-resolved electron spectrometer capable of uniquely efficient and high energy resolution measurements. Spin analysis is obtained through polarimetry based on low-energy exchange scattering from a ferromagnetic thin-film target. This approach can achieve a similar analyzing power (Sherman function) as state-of-the-art Mott scattering polarimeters, but with as much as 100 times improved efficiency due to increased reflectivity. Performance is further enhanced by integrating the polarimeter into a time-of-flight (TOF) based energy analysis scheme with a precise and flexible elec…