The use of Thin-foil Proton Recoil (TPR) spectrometers for application in neutron spectroscopy is of high relevance for future fusion devices such as ITER, where neutron spectroscopy will play a crucial role in fuel content monitoring. Existing research based on simulations of the performance of TPR spectrometers at ITER has demonstrated positive results. However, experimental validation of the simulations would greatly benefit the reliability of conclusions. In this study, we designed and constructed a prototype TPR neutron spectrometer and employed a DT neutron generator as a neutron source to perform measurements. We compared the experimental results with the simulation results using the Geant4 model of the experiment. The simulation and experimental results match within silicon detector intrinsic energy resolution. This approach ensures the experimental validation of the Geant4 based simulations of the TPR spectrometer. The experimental results demonstrated the feasibility of utilizing nuclear reactions measured in silicon detectors, specifically $^{28}$Si(n,d) and $^{28}$Si(n,$α$), for energy calibration purposes. A comparison of the experiment and the simulation shows that the mean peak energy and full width at half maximum are within 150 keV. The calculated detector efficiency underestimates the experimentally determined efficiency up to 33\%. Discrepancies in the measured energy spectrum indicate the need for a more refined model and experiment control. Overall, the successful validation of the developed Geant4 simulation model against the experimentally measured energy spectra increases confidence in the applicability of such simulation results in other devices. The demonstrated energy calibration highlights new possibilities for neutron spectrometer monitoring during operation at ITER.
Effects of 3D printed capsule material on activation thin foil irradiation and counting for fusion neutron yield measurements
Plasma Science and Fusion Center, Massachusetts Institute of Technology(麻省理工学院等离子体科学与聚变中心);Commonwealth Fusion System(联邦聚变系统);Coastal Carolina University(沿海卡罗来纳大学)
Geant4 simulation of the PSI LEM beam line: energy loss and muonium formation in thin foils and the impact of unmoderated muons on the $μ$SR spectrometer
Transmission Efficiency of the Recoil Mass Spectrometer EMMA at TRIUMF
TRIUMF;Department of Physics, Simon Fraser University(西蒙菲莎大学物理系);Department of Chemistry, San José State University(圣何塞州立大学化学系);Department of Nuclear Engineering, Hanyang University(汉阳大学核工程系);Department of Physics, University of Surrey(萨里大学物理系);Department of Physics, University of York(约克大学物理系)
Design and characterization of a recoil ion momentum spectrometer for investigating molecular fragmentation dynamics upon MeV energy ion impact ionization
DSSSD based Spectrometer of the Dubna Gas-Filled Recoil Separator
最近,在DGFRS相关实验中,成功地发现了新的超重元素114至118。至于背景自由基抑制,在这些实验中,它是即主动相关的方法,这是适用于这一目标。注意,DSSSD检测器的应用允许人们更有效地应用该方法,尽管由于相邻条带边缘效应而具有一些困难。本文介绍了DGFRS光谱仪的现有版本。本文给出了自然Yb+48Ca反应中的ER记录能谱。本文还介绍了它在240 Pu +48 Ca =Fl全聚变核反应中的初步应用结果。最后得出结论,边缘效应可以用条纹间面积的作用来近似解释。
Commissioning of a mobile neutron spectrometer for LNGS
University of L’Aquila(拉奎拉大学);INFN, Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所,格兰萨索国家实验室);Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院);Heidelberg University(海德堡大学)
Measurement of Muon-induced High-energy Neutrons from Rock in an Underground Gd-doped Water Detector
我们提出了一个测量的相关中子捕获率的手表男孩探测器,部署在深度约390米水当量(m.w.e.)。Kimballton Underground Research Facility(KURF)WATCHBOY由一个2吨重的圆柱形水靶组成,其中掺杂了0.1%的钆,周围有一个40吨重的无掺杂水密封屏蔽层。我们提出了一个比较我们的结果与预期的相关中子捕获率所产生的高能中子入射在外面的手表屏蔽,预测的混合FLUKA/GEANT 4为基础的模拟。模拟中使用的入射中子能量分布是由快中子谱仪,1.8吨多重和反冲谱仪(MARS)探测器,在同一深度测量的。我们发现,测量的两个相关的中子的探测率是一致的模拟预测。这一结果为MARS使用的探测技术提供了额外的信心,因此也为在三个不同深度测量的MARS光谱提供了信心。快中子通量和能谱的确认是重要的,因为它有助于验证用于预测不同覆盖层下快中子通量的标度模型。