TRIUMF上EMMA反冲质量谱仪的传输效率
Transmission Efficiency of the Recoil Mass Spectrometer EMMA at TRIUMF
AI总结:
研究通过不同角度孔径测量EMMA在17种动能/电荷偏差下的传输效率,结合离子光学计算和蒙特卡洛模拟,采用分段高斯函数拟合数据以描述角度和动能/电荷的关系。
摘要:
在TRIUMF上EMMA反冲质量谱仪的平均传输效率已通过6种不同的角度孔径,在相对于中心参考轨迹的17种动能/电荷偏差下进行测量。使用安装在谱仪目标位置的148Gdα源进行的测量与离子光学计算和蒙特卡洛模拟进行比较。传输效率作为角度和动能/电荷函数的经验描述通过分段高斯函数进行,其参数拟合到数据中。
英文摘要:
The mean transmission efficiency of the EMMA recoil mass spectrometer at TRIUMF has been measured with 6 different angular apertures at 17 kinetic energy/charge deviations with respect to the central, reference trajectory. Measurements performed using a 148Gd alpha source installed at the target position of the spectrometer are compared to ion-optical calculations and Monte Carlo simulations. The transmission efficiency as a function of angle and kinetic energy/charge is described empirically using piecewise Gaussian functions whose parameters are fit to the data.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。