本文介绍了一种低温恒温器的发展,旨在提高低能量阈值(低于0.5 keV)的p型点接触锗γ射线谱仪。超低能量阈值在低能核反冲的探测中是重要的,低能核反冲是与暗物质直接探测和相干中微子-核散射测量相关的事件类别。低温恒温器的设计,包括一个热和电场模型,给出。一个原型低温恒温器已组装和数据采集,以评估其真空和热性能。

英文摘要:

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The cryostat design, including a thermal and electrical-field model, is given. A prototype cryostat has been assembled and data acquired to evaluate its vacuum and thermal performance.