双面条形高纯度锗探测器的深度校准用于科姆pton光谱仪和成像卫星

Depth Calibration of Double-sided Strip Germanium Detectors for the Compton Spectrometer and Imager Satellite

University of California, Berkeley(加州大学伯克利分校);University of California, San Diego(加州大学圣地亚哥分校);NASA Goddard Space Flight Center(美国国家航空航天局戈达德太空飞行中心)
Field R. Rogers, Sean N. Pike, Samer Alnussirat, Robin Anthony-Petersen, Steven E. Boggs, Felix Hagemann, Sophia E. Haight, Alyson Joens, Carolyn Kierans, Alexa… 展开作者

Field R. Rogers, Sean N. Pike, Samer Alnussirat, Robin Anthony-Petersen, Steven E. Boggs, Felix Hagemann, Sophia E. Haight, Alyson Joens, Carolyn Kierans, Alexander Lowell, Brent Mochizuki, Albert Y. Shih, Clio Sleator, John A. Tomsick, Andreas Zoglauer

AI总结:

本文首次展示了用于COSI卫星的双面条形高纯度锗探测器的深度校准,通过模拟和数据验证,实现了高分辨率的深度测量。

摘要:

双面条形高纯度锗探测器具有三维位置重建能力,经过三十年的发展,在高能天体物理和日物理学中已应用于空间应用。三维位置分辨率对于重建康普顿散射事件至关重要,包括即将发射的康普顿光谱仪和成像卫星(COSI)任务。通过将两个探测器面分割成正交的条形接触来实现二维位置重建,从而实现像素化分析。交互深度不能直接测量,必须通过探测器两个面之间的电荷收集时间差来推断。在这里,我们首次展示了使用为COSI任务开发的应用专用集成电路(ASIC)读出的探测器的深度校准。在本工作中,我们使用基于Julia的模拟包SolidStateDetectors$.$jl将电荷收集时间差映射到深度,并通过与观测到的定时分布的比较来验证。我们还利用模拟和数据证明了每个像素的深度分辨率,其中超过90%的像素在59.5 keV时具有<0.9 mm(FWHM)的分辨率,在122.1 keV时具有<0.6 mm(FWHM)的分辨率。

英文摘要:

Double-sided strip high-purity germanium detectors with three-dimensional position reconstruction capability have been developed over three decades, with space-based applications in high-energy astrophysics and heliophysics. Position resolution in three dimensions is key to reconstruction of Compton scattering events, including for the upcoming Compton Spectrometer and Imager (COSI) satellite mission. Two-dimensional position reconstruction is enabled by segmentation of the two detector faces into orthogonal strip contacts, enabling a pixelized analysis. The depth of an interaction cannot be measured directly but must be inferred from the charge collection time difference between the two faces of the detector. Here, we demonstrate for the first time the depth calibration of a detector with the COSI satellite geometry read out using an application specific integrated circuit (ASIC) developed for the COSI mission. In this work, we map collection time difference to depth using the Julia-based simulation package SolidStateDetectors$.$jl and validate it with comparison to the timing distributions observed in data. We also use simulations and data to demonstrate the depth resolution on a per-pixel basis, with >90% of pixels having <0.9 mm (FWHM) resolution at 59.5 keV and <0.6 mm (FWHM) resolution at 122.1 keV.