针对前列腺MRI偏置场校正难题,提出结合Hadamard U-Net与条件变分自编码器的PHU-Net,可快速生成高质量校正图像,提升前列腺MRI分割精度。

摘要:

磁场不均匀性校正仍是MRI分析中的一项挑战性任务。大多数成熟技术都是针对脑部MRI设计的,其假设同一组织内的图像强度服从均匀分布。这一假设难以应用于其他器官,尤其是那些尺寸小、纹理异质性强(强度变化大)的器官,例如前列腺。为解决该问题,本文提出一种用于前列腺MRI偏置场校正的概率型Hadamard U-Net(PHU-Net)。首先,本文提出一种新型Hadamard U-Net(HU-Net)用于提取低频标量场,将其与原始输入相乘得到原型校正图像。HU-Net通过Hadamard变换将输入图像从时域转换到频域。在频域中,利用可训练滤波器(缩放层)、硬阈值层和稀疏性惩罚去除高频分量。随后,采用条件变分自编码器将可能的偏置场校正变体编码到低维潜空间中。从潜空间中抽取的随机样本再与原型校正图像结合,生成多幅合理的校正图像。实验结果表明,PHU-Net在前列腺MRI偏置场校正中具有有效性,且推理速度快。研究还显示,借助PHU-Net生成的高质量校正图像,前列腺MRI的分割精度得到提升。代码将在本论文的最终版本中提供。

英文摘要:

Magnetic field inhomogeneity correction remains a challenging task in MRI analysis. Most established techniques are designed for brain MRI by supposing that image intensities in the identical tissue follow a uniform distribution. Such an assumption cannot be easily applied to other organs, especially those that are small in size and heterogeneous in texture (large variations in intensity), such as the prostate. To address this problem, this paper proposes a probabilistic Hadamard U-Net (PHU-Net) for prostate MRI bias field correction. First, a novel Hadamard U-Net (HU-Net) is introduced to extract the low-frequency scalar field, multiplied by the original input to obtain the prototypical corrected image. HU-Net converts the input image from the time domain into the frequency domain via Hadamard transform. In the frequency domain, high-frequency components are eliminated using the trainable filter (scaling layer), hard-thresholding layer, and sparsity penalty. Next, a conditional variational autoencoder is used to encode possible bias field-corrected variants into a low-dimensional latent space. Random samples drawn from latent space are then incorporated with a prototypical corrected image to generate multiple plausible images. Experimental results demonstrate the effectiveness of PHU-Net in correcting bias-field in prostate MRI with a fast inference speed. It has also been shown that prostate MRI segmentation accuracy improves with the high-quality corrected images from PHU-Net. The code will be available in the final version of this manuscript.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑