Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates ($\bar{DR}$) above 100 Gy/s and doses per pulse ($D_p$) exceeding 1.5 Gy typical of UHDR (FLASH)-RT. The aim of this study was to characterize a novel scintillator dosimetry system with the potential of accommodating UHDRs. Methods: A thorough dosimetric characterization of the system was performed on an UHDR electron beamline. The system's response as a function of dose, $\bar{DR}$, $D_p$, and the pulse dose rate ${DR}_p$ was investigated, together with the system's dose sensitivity (signal per unit dose) as a function of dose history. The capabilities of the system for time-resolved dosimetric readout were also evaluated. Results: Within a tolerance of $\pm$3% the system exhibited dose linearity and was independent of $\bar{DR}$ and $D_p$ within the tested ranges of 1.8-1341 Gy/s and 0.005-7.68 Gy, respectively. A 6% reduction in the signal per unit dose was observed as ${DR}_p$ was increased from 8.9e4-1.8e6 Gy/s. Additionally, the dose delivered per integration window of the continuously sampling photodetector had to remain between 0.028 and 11.64 Gy to preserve a stable signal response per unit dose. The system accurately measured $D_p$ of individual pulses delivered at up to 120 Hz. The day-to-day variation of the signal per unit dose at a reference setup varied by up to $\pm$13% but remained consistent (<$\pm$2%) within each day of measurements and showed no signal loss as a function of dose history. Conclusions: With daily calibrations and ${DR}_p$ specific correction factors, the system reliably provides real-time, millisecond-resolved dosimetric measurements of pulsed conventional and UHDR beams from typical electron linacs, marking an important advancement in UHDR dosimetry.
Characterization of a novel plastic scintillation detector for in vivo electron dosimetry
University Medical Centre Mannheim, Heidelberg University(海德堡大学曼海姆医学中心);DKFZ-Hector Cancer Institute, University Medical Centre Mannheim(德国癌症研究中心-海克特癌症研究所,曼海姆医学中心);Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty Mannheim, Heidelberg University(海德堡大学曼海姆医学院曼海姆智能医学系统研究所)
A mathematical approach to aspects of LET, micro- and nano-dosimetry in radiation therapy with photons and charged particles
Co ~(60)的辐射效应作为考虑正常和肿瘤组织剂量效应关系中LET和RBE的参考系,通常采用线性二次模型(LQ)处理。这种近似非常适合肩部区域。在粒子治疗中,我们在初始平台和布拉格峰的环境中的RBE之间有严格的区别。因此,对于质子,初始平台的LET和RBE与Co 60一致,而在布拉格峰域中,这两种性质都增加,但SOBP的RBE仅在1.1和1.17之间变化。碳离子的RBE再次增加,由于密集的电离辐射效应,它们的剂量效应曲线更陡,肩域相当小。因此,质子在布拉格峰区域也是密集电离的,但与碳离子相比具有相当小的幅度。基于非线性反应扩散模型,提出了一种推广的LQ模型,用于描述致密电离粒子的LET和RBE,该模型考虑了微米和纳米剂量学的性质。反应扩散公式中的线性项描述了细胞的破坏,非线性项与修复有关,扩散项反映了辐射损伤的密度。根据Co_(60)的剂量-效应特性,可以确定致密电离粒子的参数,并与测量数据进行比较。RBE和剂量效应曲线中辐射效应的局部密集性及其后果提供了理解不同模态的现代治疗计划的关键,并通过数学描述解释了纳米剂量学的性质。球状体的照射是微剂量测定的特征,而细胞内暴露是指纳米剂量测定。
New dosimetry planning strategy based on continuous dose gradient used to reduce dose estimation errors due to respiratory motion in breast radiation therapy
Wide Area Surface Dosimetry with Conformal Scintillator Array for External Beam Radiotherapy
Thayer School of Engineering, Dartmouth College(达特茅斯学院泰勒工程学院);Department of Radiation Oncology and Applied Sciences, Geisel School of Medicine, Dartmouth College(达特茅斯学院吉泽尔医学院放射肿瘤与应用科学系)
Artificial intelligence for simplified patient-centered dosimetry in radiopharmaceutical therapies
Bern University Hospital, University of Bern(伯尔尼大学医院,伯尔尼大学);BC Cancer Research(不列颠哥伦比亚省癌症研究中心);Geneva University Hospital(日内瓦大学医院);University of British Columbia(不列颠哥伦比亚大学)
Analytical expressions for stopping-power ratios relevant for accurate dosimetry in particle therapy
在粒子治疗中,精确的电离室剂量测定需要了解离子束对空气和水的停止功率比(STPR)。早期的工作已经研究了原始碳离子束的STPR,但在这里,我们将计算扩展到离子范围(1 <= z <= 18)以及分散布拉格峰(SOBP),并提供了一个理论上的深入研究,特别关注与粒子治疗相关的参数机制。蒙特卡罗输运程序SHIELD-HIT用于计算根据国际原子能机构(IAEA)的建议确定STPR所需的完整粒子注量谱。我们确认,STPR主要取决于当前的离子的能量,而不是他们的电荷z或在介质中的绝对位置。然而,STPR为不同的停止功率数据的水和空气的国际辐射单位与测量委员会(ICRU)建议的比较,包括最近修订的数据水,在高原地区产生的偏差高达2%。相比之下,二次粒子谱对STPR的影响在整个区域内直到实际范围都要小两个数量级。所获得的见解,使我们能够提出一个解析近似的STPR为原始和SOBPs作为穿透深度的函数,参数仅依赖于初始能量和离子的残留范围,分别。
An innovative dose rate independent 2D Ce-doped YAG scintillating dosimetry system for time resolved beam monitoring in ultra-high dose rate electron FLASH radiation therapy
Roadmap towards Personalized Approaches and Safety Considerations in Non-Ionizing Radiation: From Dosimetry to Therapeutic and Diagnostic Applications
Aalto University(阿尔托大学);Eindhoven University of Technology(埃因霍温理工大学);Erasmus University Medical Center Cancer Institute(伊拉斯谟斯大学医学中心癌症研究所);Nagoya Institute of Technology(名古屋工业大学);Korea Advanced Institute of Science and Technology(韩国科学技术院);University of Wisconsin-Madison(威斯康星大学麦迪逊分校);Sapienza University of Rome(罗马第一大学);University of Houston(休斯顿大学);National Institute of Mental Health, NIH(美国国立精神卫生研究所);University of L’Aquila(拉奎拉大学);South China Agricultural University(华南农业大学);University of Malta(马耳他大学);CNR – National Research Council, Institute of Electronics Computer and Telecommunication (IEIIT)(意大利国家研究委员会电子计算机与电信研究所);Delft University of Technology(代尔夫特理工大学);Hokkaido University(北海道大学);Worcester Polytechnic Institute(伍斯特理工学院);Athinoula A. Martinos Ctr. for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School(哈佛大学医学院马萨诸塞总医院阿西诺拉A马丁诺斯生物医学成像中心);National Institute of Information and Communications Technology(日本信息通信研究机构);University of Minnesota(明尼苏达大学);University of Warwick(华威大学);The George Washington University(乔治华盛顿大学);University of Maryland School of Medicine(马里兰大学医学院)
From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy
Adapting a 3D scanning water phantom for use in brachytherapy dosimetry
Royal Brisbane & Women’s Hospital(皇家布里斯班妇女医院);Herston Biofabrication Institute(赫斯顿生物制造研究所);University of Queensland(昆士兰大学);Queensland University of Technology(昆士兰科技大学)
Commissioning, characterization and first high dose rate irradiations at a compact X-ray tube for microbeam and minibeam radiation therapy
Technical University of Munich, TUM School of Medicine and Health, Department of Radiation Oncology, TUM University Hospital(慕尼黑工业大学,医学院与健康学院,放射肿瘤学系,慕尼黑工业大学附属医院);Technical University of Munich, School of Natural Sciences, Department of Physics(慕尼黑工业大学,自然科学学院,物理系);Heinz Maier-Leibnitz Zentrum (MLZ)(海因茨·迈尔-莱布尼茨中心);Helmholtz-Institute Mainz, Accelerator Design and Integrated Detectors(美因茨亥姆霍兹研究所,加速器设计与集成探测器);Technical University of Munich, TUM School of Medicine and Health, Department of Nuclear Medicine, TUM University Hospital(慕尼黑工业大学,医学院与健康学院,核医学科,慕尼黑工业大学附属医院);Technical University of Munich, Munich Institute of Biomedical Engineering(慕尼黑工业大学,慕尼黑生物医学工程研究所);German Cancer Consortium (DKTK), Partner Site Munich and German Cancer Research Center (DKFZ)(德国癌症联盟(DKTK),慕尼黑合作站点和德国癌症研究中心(DKFZ));ISF, Faculty of Mechanical Engineering, RWTH Aachen University(ISF,机械工程学院,亚琛工业大学);Johannes Gutenberg University, Institute for Nuclear Physics(约翰内斯·古腾堡大学,核物理研究所)
Dose Validation of GRID Block Treatment Applicator within the RayStation Treatment Planning System
University of Rhode Island(罗德岛大学);Mary Bird Perkins Cancer Center(玛丽·伯德·珀金斯癌症中心);Indiana University Medical School(印第安纳大学医学院);Warren Alpert Medical School of Brown University(布朗大学沃伦·阿尔帕特医学院)
External beam irradiation angle measurement using Cerenkov emission I: Signal dependencies consideration
本研究介绍了一种新型的混合切伦科夫闪烁剂量计,其目的是用于照射角度测量的切伦科夫角度依赖性的基础上。第一测量旨在通过同时测量沉积剂量来验证解释切伦科夫电子能谱依赖性的能力,从而隔离由角度依赖性引起的信号变化。切伦科夫探头是由一个10毫米长的透明PMMA光纤的敏感体积由一个吸收过滤器从1毫米直径的传输光纤分离。使用Hyperscint RP-200闪烁剂量测定平台分别收集来自敏感体积和传输光纤的过滤和原始Cerenkov信号。使用高光谱方法对总信号进行解混。用光子和电子束完成探测器信号的剂量校准。使用固体水模型,在固定的入射角,涵盖了广泛的剂量和输出因子的测量实现。对于固定的入射角,切伦科夫检测器的信号表征显示线性剂量-光关系。正如预期的那样,发现灵敏体积信号是能量依赖性的。对于高达25 cm x 25 cm的场尺寸,使用光子和电子,输出因子精确测量在0.8%以内。第一次验证的切伦科夫角度依赖性显示了一个线性的剂量-光的关系,为整个范围内的角度测试。正如预期的那样,由于角度依赖性,每剂量单位的切伦科夫信号强度基于照射角度而变化。结果表明,使用电子能谱类似于测量条件的校准条件允许依赖于沉积剂量来解释这种依赖性。这些初步结果构成了实验照射角测量的第一步。