arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2401.08451physics.med-ph
收藏

小鼠肿瘤中 radon-220 扩散的首次测量:迈向扩散 α 发射体放射治疗中的治疗规划

First measurements of radon-220 diffusion in mice tumors, towards treatment planning in diffusing alpha-emitters radiation therapy

Guy Heger, Mirta Dumančić, Ishai Luz, Maayan Vatarescu, Noam Weizman, Brian W. Miller, Tomer Cooks, Lior Arazi

AI总结:

本研究通过 24 个小鼠皮下肿瘤的放射自显影测量,首次实验估计 Alpha-DaRT 中 radon-220 的扩散长度,并发现体内远处活度扩散可能与血管贡献有关。

摘要:

Alpha-DaRT 是一种利用 α 粒子治疗实体瘤的新方法,其依赖于从插入肿瘤内的源中释放 radium-224 的发射 α 粒子的子体原子。Alpha-DaRT 剂量学中最重要的模型参数是 radon-220 和 lead-212 的扩散长度,对其进行估计对于治疗规划至关重要。本工作的目标是提供 radon-220 扩散长度的首批实验估计值。radon-220 的扩散长度是通过对取自 24 个小鼠携带的、五种不同类型皮下肿瘤的组织学切片进行放射自显影测量来估计的。实验分两组进行:14 个体内肿瘤,在治疗期间这些肿瘤仍由具有活跃血液供应的小鼠携带;以及 10 个体外肿瘤,这些肿瘤在插入源之前被切除,并在源位于其中的情况下保存于 37 摄氏度的培养基中。测得的 radon-220 扩散长度位于 0.25–0.6 mm 范围内,体内和体外肿瘤测得的平均值之间没有显著差异:体内为 0.40 ± 0.08 mm,而体外为 0.39 ± 0.07 mm。然而,体内肿瘤在距源 2–3 mm 处表现出增强的活度扩散。这一效应无法由当前模型解释,并且在体外肿瘤中明显较弱。体内和体外肿瘤中测得的 radon-220 平均扩散长度均接近此前估计的 0.2–0.4 mm 范围的上限。在靠近源的位置,体内与体外肿瘤之间没有明显差异,并且该区域与理论模型吻合良好,这些观察结果表明 radon-220 在该区域的扩散主要为扩散性传播。体内肿瘤在较大径向距离处偏离模型预测,可能暗示存在潜在的血管贡献。

英文摘要:

Alpha-DaRT is a new method for treating solid tumors with alpha particles, relying on the release of the alpha-emitting daughter atoms of radium-224 from sources inserted into the tumor. The most important model parameters for Alpha-DaRT dosimetry are the diffusion lengths of radon-220 and lead-212, and their estimation is essential for treatment planning. The aim of this work is to provide first experimental estimates for the diffusion length of radon-220. The diffusion length of radon-220 was estimated from autoradiography measurements of histological sections taken from 24 mice-borne subcutaneous tumors of five different types. Experiments were done in two sets: fourteen in-vivo tumors, where during the treatment the tumors were still carried by the mice with active blood supply, and ten ex-vivo tumors, where the tumors were excised before source insertion and kept in a medium at 37 degrees C with the source inside. The measured diffusion lengths of radon-220 lie in the range 0.25-0.6 mm, with no significant difference between the average values measured in in-vivo and ex-vivo tumors: 0.40 $\pm$ 0.08 mm for in-vivo vs. 0.39 $\pm$ 0.07 mm for ex-vivo. However, in-vivo tumors display an enhanced spread of activity 2-3 mm away from the source. This effect is not explained by the current model and is much less pronounced in ex-vivo tumors. The average measured radon-220 diffusion lengths in both in-vivo and ex-vivo tumors lie close to the upper limit of the previously estimated range of 0.2-0.4 mm. The observation that close to the source there is no apparent difference between in-vivo and ex-vivo tumors, and the good agreement with the theoretical model in this region suggest that the spread of radon-220 is predominantly diffusive in this region. The departure from the model prediction in in-vivo tumors at large radial distances may hint at potential vascular contribution.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑