arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2402.04473physics.ins-dethep-ex
收藏

NEXUS低温设施中动力学电感声子介导探测器的性能

Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

Dylan J Temples, Osmond Wen, Karthik Ramanathan, Taylor Aralis, Yen-Yung Chang, Sunil Golwala, Lauren Hsu, Corey Bathurst, Daniel Baxter, Daniel Bowring, Ran Ch… 展开作者

Dylan J Temples, Osmond Wen, Karthik Ramanathan, Taylor Aralis, Yen-Yung Chang, Sunil Golwala, Lauren Hsu, Corey Bathurst, Daniel Baxter, Daniel Bowring, Ran Chen, Enectali Figueroa-Feliciano, Matthew Hollister, Christopher James, Kyle Kennard, Noah Kurinsky, Samantha Lewis, Patrick Lukens, Valentina Novati, Runze Ren, Benjamin Schmidt

AI总结:

本文报道了在NEXUS设施中运行的KIPM原型探测器,通过470 nm光子校准实现了2.1 eV的声子传感基线分辨率,并分析了准粒子寿命和噪声对能量分辨率的影响。

摘要:

利用微波动力学电感探测器读取粒子吸收靶中声子信号的微量热计,被称为动力学电感声子介导(KIPM)探测器,为探索暗物质(DM)直至费米子热遗迹质量极限提供了一种有吸引力的探测器架构。一个原型KIPM探测器在费米实验室的NEXUS低本底设施中运行,该探测器在1克硅衬底上图案化了一个单一铝谐振器,用于表征和评估该探测器架构在暗物质搜索中的有效性。通过将裸衬底暴露于470 nm光子的脉冲源进行能量校准,声子传感器吸收能量的基线分辨率为$2.1\pm0.2$ eV,比当前最先进水平好两倍,这得益于毫秒级的准粒子寿命。然而,由于声子收集效率低于百分之一,衬底中沉积能量的分辨率被限制为$σ_E=318 \pm 28$ eV。我们进一步将信号脉冲形状建模为器件温度的函数,以提取准粒子寿命以及观测到的噪声谱,这两者都影响传感器的基线分辨率。

英文摘要:

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $σ_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑