High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
F. Bellini, L. Cardani, N. Casali, M. G. Castellano, I. Colantoni, C. Cosmelli, A. Cruciani, A. D'Addabbo, S. Di Domizio, M. Martinez, C. Tomei, M. Vignati
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and the natural multiplexed read-out, Kinetic Inductance Detectors (KIDs) are particularly suitable for this purpose. To efficiently couple KIDs-based light detectors to the large crystals used by the most advanced bolometric detectors, active surfaces of several cm$^2$ are needed. For this reason, we are developing phonon-mediated detectors. In this paper we pr…
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Washington University in St. Louis(圣路易斯华盛顿大学);SLAC National Accelerator Laboratory(斯坦福直线加速器中心);California Institute of Technology(加州理工学院);University of California, Berkeley(加州大学伯克利分校);Stanford University(斯坦福大学)
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally m…
Exploring the proximity effect of thin tungsten-aluminum films for phonon-mediated kinetic inductance detectors
INFN - Sezione di Roma(意大利国家核物理研究所罗马分部);Max-Planck-Institut für Physik(马克斯·普朗克物理研究所);LIBPhys-UC, Departamento de Fisica, Universidade de Coimbra(科英布拉大学LIBPhys);Dipartimento di Fisica, Sapienza Università di Roma(罗马第一大学物理系);Université Grenoble Alpes, CNRS, Grenoble INP, Institut Néel(格勒诺布尔阿尔卑斯大学)
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per readout line. We describe a novel readout system for large arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout, which is a combination of a digital front- and back-end and an an…
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photon…
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 -- 8 GH…
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every category of size, weight, power, cost, and bandwidth over the previous generation readout systems. We describe a baseline firmware design which can read out four independent RF networks each with 500 MH…
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited in the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle life…
Kinetic inductance bolometer (KIB) technology is a candidate for passive sub-millimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature range of 5 -- 10 K. We have previously demonstrated the scalability in terms of device fabrication, optics integration, and cryogenics. In this article, we address the last missing ingredient, the readout. The concept, serial addressed frequency excitation (SAFE), is an alternative to full frequency-division multiplexing at microwave frequencies conventional…
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of cutting-edge superconducting detector. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We …
We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux th…
An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators
Arizona State University(亚利桑那州立大学);California Institute of Technology(加州理工学院);NASA Jet Propulsion Laboratory(美国国家航空航天局喷气推进实验室);University of Virginia(弗吉尼亚大学);Johns Hopkins University(约翰斯·霍普金斯大学);Custom Design and Instrumentation, LLC(Custom Design and Instrumentation有限责任公司)
Molybdenum based crystals such as Li$_2$MoO$_4$ and CaMoO$_4$ are emerging as leading candidates for next generation experiments searching for neutrino-less double beta decay with cryogenic calorimeters (CUPID, AMoRE). The exquisite energy resolution and high radio-purity of these crystals come at the cost of a potentially detrimental background source: the two neutrinos double beta decay of $^{100}$Mo. Indeed, the fast half-life of this decay mode, combined with the slow response of cryogenic calorimeters, would result in pile-up events in the energy region of interest for neutrino-less doubl…
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an inte…
To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temperature dependent box resonances are absent. The dark KID properties have been measured in a large set of resonators. A surprisingly long lifetime, up to 5.6 ms is observed in a few KIDs. For the othe…
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors allows simultaneous read-out of the light and heat signals and enables background suppression through particle identification. The Cryogenic wide- Area Light Detector with Excellent Resolution (CALDER) R&D already proved the potential of this technique using the phonon-mediated Kinetic Inductance Detectors (KIDs) approach. The first array prototype with 4 Alum…
We have developed a passive 350 GHz (850 μm) video-camera to demonstrate lumped element kinetic inductance detectors (LEKIDs) -- designed originally for far-infrared astronomy -- as an option for general purpose terrestrial terahertz imaging applications. The camera currently operates at a quasi-video frame rate of 2 Hz with a noise equivalent temperature difference per frame of $\sim$0.1 K, which is close to the background limit. The 152 element superconducting LEKID array is fabricated from a simple 40 nm aluminum film on a silicon dielectric substrate and is read out through a single microw…
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium M…
In Kinetic Inductance Detectors (KIDs) and other similar applications of superconducting microresonators, both the large and small-signal behaviour of the device may be affected by electrothermal feedback. Microwave power applied to read out the device is absorbed by and heats the superconductor quasiparticles, changing the superconductor conductivity and hence the readout power absorbed in a positive or negative feedback loop. In this work, we explore numerically the implications of an extensible theoretical model of a generic superconducting microresonator device for a typical KID, incorpora…
One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and limit the array yield. Here we study the resonance frequency deviation of a 4-inch kilo-pixel lumped-element kinetic inductance detector (LEKID) array using optical mapping. Using the measured resonator dimensions and film thickness, the fractional deviation can be explained within $\pm 25\times 10^{-3}$, whereas the residual deviation is due to variation of…
Ultrasensitive magnetic field detection is utilized in the fields of science, medicine and industry. We report on a novel magnetometer relying on the kinetic inductance of superconducting material. The kinetic inductance exhibits a non-linear response with respect to DC current, a fact that is exploited by applying magnetic flux through a superconducting loop to generate a shielding current and a change in the inductance of the loop. The magnetometer is arranged into a resonator, allowing readout through a transmission measurement that makes the device compatible with radio frequency multiplex…
Different terrestrial terahertz applications would benefit from large-format arrays, operating in compact and inexpensive cryocoolers at liquid helium temperature with sensitivity, limited by the 300-K background radiation only. A voltage-biased Transition-Edge Sensor (TES) as a THz detector can have sufficient sensitivity and has a number of advantages important for real applications as linearity of response, high dynamic range and a simple calibration, however it requires a low-noise current readout. Usually, a current amplifier based on Superconducting Quantum-Interference Device (SQUID) is…
We present a design for an array of kinetic inductance detectors (KIDs) integrated with phased array antennas for imaging at 150 GHz under high background conditions. The microstrip geometry KID detectors are projected to achieve photon noise limited sensitivity with larger than 100 pW absorbed optical power. Both the microstrip KIDs and the antenna feed network make use of a low-loss amorphous silicon dielectric. A new aspect of the antenna implementation is the use of a NbTiN microstrip feed network to facilitate impedance matching to the 50 Ohm antenna. The array has 256 pixels on a 6-inch …
We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure power through the temperature-dependent resonant frequency of a superconducting microresonator bolometer. At high readout probe power and probe frequency detuned from the TKID resonant frequency, we observe electrothermal feedback loop gain up to $\mathcal L$ $\approx$ 16 through measuring the reduction of settling time. We also show that the detector respons…
We present recent developments in Kinetic Inductance Detectors (KID) for large arrays of detectors. The main application is ground-based millimeter wave astronomy. We focus in particular, as a case study, on our own experiment: NIKA (Néel IRAM KID Arrays). NIKA is today the best in-the-field experiment using KID-based instruments, and consists of a dual-band imaging system designed for the IRAM 30 meter telescope at Pico Veleta. We describe in this article, after a general context introduction, the KID working principle and the readout electronics, crucial to take advantage of the intrinsic KI…
We present a measurement of phonon propagation in a silicon wafer utilizing an array of frequency-multiplexed superconducting resonators coupled to a single transmission line. The electronic readout permits fully synchronous array sampling with a per-resonator bandwidth of 1.2 MHz, allowing sub-$μ$s array imaging. This technological achievement is potentially vital in a variety of low-temperature applications, including single-photon counting, quantum-computing and dark-matter searches.
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both…
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a…
The kinetic inductance detector (KID) is a versatile and scalable detector technology with a wide range of applications. These superconducting detectors offer significant advantages: simple and robust fabrication, intrinsic multiplexing that will allow thousands of detectors to be read out with a single microwave line, and simple and low cost room temperature electronics. These strengths make KIDs especially attractive for HEP science via mm-wave cosmological studies. Examples of these potential cosmological observations include studying cosmic acceleration (Dark Energy) through measurements o…
The non-homogeneity in the critical temperature $T_{c}$ of an Microwave Kinetic Inductance Detector (MKID) could be caused by non-uniformity in the deposition process of the thin superconducting film. This produces low percent yield and frequency collision in the readout of the MKIDs. Here, we show the homogeneity that offers Atomic Layer Deposition (ALD). We report an improvement of up to a factor of 50 in the fractional variation of the $T_{c}$ for TiN MKIDs fabricated with Atomic Layer Deposition in comparison with MKIDs fabricated with sputtering. We measured the critical temperature of 48…
Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang …
We describe sensitive magnetometry using lumped-element resonators fabricated from a superconducting thin film of NbTiN. Taking advantage of the large kinetic inductance of the superconductor, we demonstrate a continuous resonance frequency shift of $27$ MHz for a change in magnetic field of $1.8~μ$T within a perpendicular background field of 60 mT. By using phase-sensitive readout of microwaves transmitted through the sensors, we measure phase shifts in real time with a sensitivity of $1$ degree/nT. We present measurements of the noise spectral density of the sensors, and find their field sen…
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulat…
We have fabricated 2024 pixel microwave kinetic inductance detector (MKID) arrays in the ultraviolet/optical/near-IR (UVOIR) regime that are currently in use in astronomical instruments. In order to make MKIDs desirable for novel instruments, larger arrays with nearly perfect yield need to be fabricated. As array size increases, however, the percent yield often decreases due to frequency collisions in the readout. The per-pixel performance must also be improved, namely the energy resolution. We are investigating ways to reduce frequency collisions and to improve the per pixel performance of ou…
Kilopixel Performance of the Kinetic Inductance Detectors for the Terahertz Intensity Mapper
University of California, Los Angeles(加州大学洛杉矶分校);California Institute of Technology(加州理工学院);Jet Propulsion Laboratory, California Institute of Technology(加州理工学院喷气推进实验室);Arizona State University(亚利桑那州立大学)
Microwave Kinetic Inductance Detectors (MKIDs) are cryogenic photon detectors and are attractive because they permit simultaneous time, energy and spatial resolution of faint astronomical sources. We present a cost-effective alternative to dedicated (e.g. analogue) electronics for prototyping readout of single-pixel Optical/NIR MKIDs by repurposing existing and well-known ROACH-1 boards. We also present a pipeline that modernises previously-developed software and data frameworks to allow for extensiblity to new applications and portability to new hardware (e.g. Xilinx ZCU111 or 2x2 RFSoC board…
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden. The instrument contains 2317 single-polarization, horn-coupled, aluminum lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be maintained at 100 mK with an adiabatic demagnetization refrigerator. The polarimeter operates in two configurations, one sensitive to a spectral band…
We present a compact current sensor based on a superconducting microwave lumped-element resonator with a nanowire kinetic inductor, operating at 4.2 K. The sensor is suitable for multiplexed readout in GHz range of large-format arrays of cryogenic detectors. The device consists of a lumped-element resonant circuit, fabricated from a single 4-nm-thick superconducting layer of niobium nitride. Thus, the fabrication and operation is significantly simplified in comparison to state-of-the-art approaches. Because the resonant circuit is inductively coupled to the feed line the current to be measured…
Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution. Substantial efforts have been devoted to developing a high spatial and temporal resolution neutron imager. We have been developing a neutron imager aiming at conducting high spatial and temporal resolution imaging based on a delay-line neutron detector, called the current-biased kinetic-inductance detector, with a conversion layer $^{10}$B. The detector allowed …
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their well-established reproducibility, Kinetic Inductance Detectors (KIDs) are good candidates for the development of next generation light detectors. The CALDER project is investigating the potential of p…
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find t…
A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID Multiplexers ($μ$mux) and Microwave Kinetic Inductance Detectors. In these readout schemes, sky signal is encoded as resonance frequency changes. One way to interrogate these superconducting resonators is to calibrate the probe tone phase such that any sky signal induced frequency shifts from the resonators show up primarily as voltage changes in only one of the two…
CCAT: Detector Noise Limited Performance of the RFSoC-based Readout Electronics for mm/sub-mm/far-IR KIDs
University of British Columbia(不列颠哥伦比亚大学);University of Victoria(维多利亚大学);Herzberg Astronomy and Astrophysics Research Centre, National Research Council Canada(加拿大国家研究委员会赫茨伯格天文学与天体物理学研究中心);Cornell University(康奈尔大学);National Institute of Standards and Technology(美国国家标准与技术研究院);University of California, Riverside(加州大学河滨分校);Arizona State University(亚利桑那州立大学)
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of band-width uti…