Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with excellent energy resolution. Despite these achievements, their resolving power has not yet reached the level required to rival modern wavelength-dispersive grating or crystal spectrometers. Here, we introduce a next-generation SQUID-based microcalorimeter concept that exploits the strong temperature dependence of the magnetic penetration depth of a superconductor operated close to its critical temperature. The resulting mutual-inductance-based readout enables in situ tunable signal amplification, while inherently avoiding hysteretic effects that commonly limit superconducting sensors. Experiments with prototype devices demonstrate robust and reproducible operation over a wide temperature range. Based on our measurements and modeling, we project that, using an optimized absorber-sensor combination, an energy resolution below 100meV (FWHM) should be achievable for soft X-ray photons with energies below 800eV. This approach therefore represents a promising pathway towards next-generation cryogenic detectors for high-precision X-ray emission spectroscopy.
The role of kinetic inductance on the performance of YBCO SQUID magnetometers
当优化由高温超导体YBa $_2$ Cu $_3$ O $_{7-x}$(YBCO)制成的超导量子干涉器件(SQUID)磁强计的性能时,电感是一个关键参数,因为较低的SQUID电感$L$导致较低的通量噪声,但也导致与拾取回路的较弱耦合。为了优化SQUID的设计,我们结合电感模拟和测量来提取不同的电感贡献,并测量的传递函数$V_Φ$和磁通噪声$S_Φ^{1/2}$对$L$的依赖性。两个样品之间的比较表明,动态电感的贡献随薄膜质量变化很大,因此使电感测量的SQUID表征的一个重要组成部分。由于改进了对动力学电感贡献的估计,可以在很大程度上避免先前发现的$V_Φ$和$S_Φ^{1/2}$的理论估计与测量值之间的差异。然后,我们使用测量结果和改进的理论估计来优化SQUID几何形状,并达到$S_B^{1/2}$ = 44 fT/ $\sqrt{\textrm{Hz}}$的噪声水平,以获得具有8.6 mm $\times$ 9.2 mm直接耦合拾取回路的最佳SQUID磁力计。最后,我们展示了一种可靠的一次性传感器校准方法,该方法在几个开尔文的温度范围内是恒定的,尽管存在温度相关的耦合贡献,如动力学电感。所发现的动态电感贡献的变化不仅对YBCO SQUID磁强计的设计有影响,而且对所有在其临界温度附近工作的基于窄线宽SQUID的器件也有影响。
A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays
Università di Milano-Bicocca(米兰比可卡大学);INFN, Sezione di Milano-Bicocca(意大利国家核物理研究所米兰比可卡分部);National Institute of Standards and Technology(美国国家标准与技术研究院);University of Colorado(科罗拉多大学)
Full-Scale Readout Electronics for the ECHo-100k Experiment
Institute for Data Processing and Electronics (IPE), Karlsruhe Institute of Technology (KIT)(数据处理与电子学研究所,卡尔斯鲁厄理工学院);Institute of Micro- and Nanoelectronic Systems (IMS), Karlsruhe Institute of Technology (KIT)(微纳电子系统研究所,卡尔斯鲁厄理工学院)