arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1807.00729physics.ins-det
收藏

基于动态电感放大器的4.2K太赫兹过渡沿传感器

Terahertz Transition-Edge Sensor with Kinetic-Inductance Amplifier at 4.2 K

Artem Kuzmin, Steffen Doerner, Stefan Singer, Ilya Charaev, Konstantin Ilin, Stefan Wuensch, Michael Siegel

摘要:

不同的地面太赫兹应用将受益于大型阵列,在液氦温度下在紧凑和廉价的低温冷却器中运行,灵敏度仅受300 K背景辐射的限制。作为THz探测器的电压偏置过渡边缘传感器(TES)具有足够的灵敏度,并且具有许多对于实际应用重要的优点,如响应线性度、高动态范围和简单的校准,但是它需要低噪声电流读出。通常,基于超导量子干涉器件(SQUID)的电流放大器用于读出,但由于操作和制造的复杂性,这种方法的可扩展性受到限制。最近,它已被证明,而不是SQUID,它是可以使用的电流传感器,这是基于非线性的动力学电感的载流超导条。将条带嵌入微波高Q超导谐振器中允许达到足够的电流灵敏度。更重要的是,它是可能的谐振器的方法,以扩大到大型阵列使用频分复用(FDM)在GHz范围。在这里,我们展示了在4.2 K的微波动电感电流放大器的电压偏置TES的操作。我们测量了预期的固有噪声等效功率NEP ~ $5\times 10^{-14} \; \rm W/Hz^{1/2}$,并证实了结合实际TES操作可以达到足够的读出灵敏度。使用新的电流放大器和已经存在的具有改进的热隔离的TES探测器的组合,可以实现在4.2 K下具有改进的灵敏度~ $10^{-15}\; \rm W/Hz^{1/2}$的阵列的构造。

英文摘要:

Different terrestrial terahertz applications would benefit from large-format arrays, operating in compact and inexpensive cryocoolers at liquid helium temperature with sensitivity, limited by the 300-K background radiation only. A voltage-biased Transition-Edge Sensor (TES) as a THz detector can have sufficient sensitivity and has a number of advantages important for real applications as linearity of response, high dynamic range and a simple calibration, however it requires a low-noise current readout. Usually, a current amplifier based on Superconducting Quantum-Interference Device (SQUID) is used for readout, but the scalability of this approach is limited due to complexity of the operation and fabrication. Recently, it has been shown that instead of SQUID it is possible to use a current sensor, which is based on the nonlinearity of the kinetic inductance of a current-carrying superconducting stripe. Embedding the stripe into a microwave high-Q superconducting resonator allows for reaching sufficient current sensitivity. More important, it is possible with the resonator approach to scale up to large arrays using Frequency-Division Multiplexing (FDM) in GHz range. Here, we demonstrate the operation of a voltage-biased TES with a microwave kinetic-inductance current amplifier at 4.2 K. We measured the expected intrinsic Noise-Equivalent Power NEP ~$5\times 10^{-14} \; \rm W/Hz^{1/2}$ and confirmed that a sufficient sensitivity of the readout can be reached in conjunction with a real TES operation. The construction of an array with the improved sensitivity ~ $10^{-15}\; \rm W/Hz^{1/2}$ at 4.2 K could be realized using a combination of the new current amplifier and already existing TES detectors with improved thermal isolation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑