arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2401.01281physics.med-ph
收藏

扫描平面对人类脊髓功能磁共振回波平面成像的影响

Influence of scanning plane on Human Spinal Cord functional Magnetic Resonance echo planar imaging

Marta Moraschi, Silvia Tommasin, Laura Maugeri, Mauro DiNuzzo, Julien Cohen-Adad, Marco Masullo, Fabio Mangini, Lorenzo Giovannelli, Daniele Mascali, Tommaso Gi… 展开作者

Marta Moraschi, Silvia Tommasin, Laura Maugeri, Mauro DiNuzzo, Julien Cohen-Adad, Marco Masullo, Fabio Mangini, Lorenzo Giovannelli, Daniele Mascali, Tommaso Gili, Valerio Pisani, Ugo Nocentini, Federico Giove, Michela Fratini

AI总结:

本研究比较了脊髓fMRI中矢状位与轴位EPI扫描的效果,发现轴位扫描在tSNR和重现性上更优,是减轻生理噪声和受试者间方差的优选方案。

摘要:

背景:功能磁共振成像(fMRI)基于血氧水平依赖(BOLD)对比度,已被用于间接研究大脑和脊髓内的神经元活动。然而,由于技术限制,脊髓fMRI(scfMRI)的解释仍存在争议,其应用也相当有限。克服这些限制将对脊髓损伤和神经退行性疾病的评估与随访产生有益影响。目的:本研究旨在系统验证使用EPI读数的scfMRI矢状位扫描是否可作为更常见的轴位扫描的可行替代方案,并基于Spinal Cord Toolbox(SCT)优化基于EPI的scfMRI数据分析流程。方法:45名健康受试者在Philips Achieva 3T MRI扫描仪中接受MRI采集。在等距运动任务期间,使用GE-EPI序列沿矢状面和轴面采集T2*加权fMRI数据。通过p=0.05的配对双样本t检验评估基准差异。结果:我们通过多种指标研究了采集策略的影响,如时间信噪比(tSNR)、评估几何畸变的Dice系数、重现性和敏感性。轴位扫描的tSNR高于矢状位扫描,且在整个脊髓掩膜(t=7.4,p<0.01)和GM掩膜(t=4.2,p<0.01)内的重现性也更高。与畸变和功能响应相关的其他基准在沿轴面和矢状面获得的图像之间未显示出差异。结论:数据质量的定量指标表明轴位扫描是最佳选择。我们得出结论,轴位采集具有优势,特别是在减轻生理噪声影响和最小化受试者间方差方面。

英文摘要:

BACKGROUND: Functional Magnetic Resonance Imaging (fMRI) is based on the Blood Oxygenation Level Dependent contrast and has been exploited for the indirect study of the neuronal activity within both the brain and the spinal cord. However, the interpretation of spinal cord fMRI (scfMRI) is still controversial and its diffusion is rather limited because of technical limitations. Overcoming these limitations would have a beneficial effect for the assessment and follow-up of spinal injuries and neurodegenerative diseases. PURPOSE: This study was aimed at systematically verify whether sagittal scanning in scfMRI using EPI readout is a viable alternative to the more common axial scanning, and at optimizing a pipeline for EPI-based scfMRI data analysis, based on Spinal Cord Toolbox (SCT). METHODS: Forty-five healthy subjects underwent MRI acquisition in a Philips Achieva 3T MRI scanner. T2*-weighted fMRI data were acquired using a GE-EPI sequence along sagittal and axial planes during an isometric motor task. Differences on benchmarks were assessed via paired two-sample t-test at p=0.05. RESULTS: We investigated the impact of the acquisition strategy by means of various metrics such as Temporal Signal to Noise Ratio (tSNR), Dice Coefficient to assess geometric distortions, Reproducibility and Sensitivity. tSNR was higher in axial than in sagittal scans, as well as reproducibility within the whole cord mask (t=7.4, p<0.01) and within the GM mask (t=4.2, p<0.01). The other benchmarks, associated with distortion and functional response, showed no difference between images obtained along the axial and sagittal planes. CONCLUSIONS: Quantitative metrics of data quality suggest that axial scanning would be the optimal choice. We conclude that axial acquisition is advantageous specially to mitigate the effects of physiological noise and to minimize inter-subject variance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑