Geometrical characterization of healthy red blood cells using digital holographic microscopy and parametric shape models for biophysical studies and diagnostic applications
Gaurav D. Bhabhor, Chetna Patel, Nishant Chhillar, Arun Anand, Kirit N. Lad
Modeling of the red blood cell (RBC) shape is an integral part of the experimental and computer simulation investigations of light scattering by these cells for fundamental studies as well as diagnostic applications in techniques like cytometry and quantitative phase imaging. In the present work, a comprehensive study of the geometrical characterization of healthy human RBCs using digital holographic microscopy (DHM) and six frequently employed parametric shape models is reported. It is shown that the comparison of the optical phase profiles, and the thickness profiles given by the models with the DHM results gives a better judgment of the appropriateness of the parametric shape models. It is also shown that the RBC parametric models offer a simpler solution to RI-thickness decoupling problem in QPI methods. Results of geometrical characterization of 500 healthy RBCs in terms of volume, surface area (SA), and sphericity index (SI) led to the classification of the parametric models in two categories based on the nature of variation of these quantities with the cell diameter. In light of the variability of the healthy RBC shapes, our findings suggest that the parametric models exhibiting a negative correlation between the SI and the cell diameter would provide more reliable estimates of the RBC parameters in diagnostic applications. Statistical distributions and descriptive statistics of the RBC volume, SA and SI serve as a guide for the assessment of the capability of the studied parametric models to give a reliable account of the variability of the healthy RBC shape and size.
Quantifying the Biophysical Properties of Red Blood Cells in Gaucher Disease
Brown University(布朗大学);Université Paris Saclay(巴黎萨克雷大学);CNRS UMR 8000(法国国家科学研究中心第8000联合研究单位);Institut de Chimie Physique(物理化学研究所);Université Paris Cité(巴黎西岱大学);INSERM(法国国家健康与医学研究院);EFS(法国血液服务机构);BIGR U1134(BIGR第1134联合研究单位);Team BioTiGR(BioTiGR团队);Initiatives IdEx Globule Rouge d’Excellence (InIdex GR-Ex)(卓越红细胞倡议(InIdex GR-Ex));Team PAMS(PAMS团队)
Superparamagnetic iron oxide polyacrylic acid coated γ-Fe2O3 nanoparticles does not affect kidney function but causes acute effect on the cardiovascular function in healthy mice
本研究描述了静脉注射聚丙烯酸(PAA)涂层γ-Fe 2 O3纳米粒(10 mg kg-1)在健康BALB/cJ小鼠器官、细胞和亚细胞水平的分布,并平行讨论了纳米粒注射对肾功能、血压和血管收缩力的影响。磁共振成像(MRI)和透射电子显微镜(TEM)显示,静脉输注后1小时内,NPs在肝脏中蓄积,通过内皮细胞和枯否细胞的细胞内摄取调节,随后在肾细胞,特别是近端小管的细胞质,足细胞和系膜细胞中的细胞内摄取调节。通过动脉酸碱状态和长期留置导管后测量肾小球滤过率(GFR)来评价NP对肾功能的影响。注射生理盐水或NP后0.5 h,小鼠动脉pH值分别为7.46和7.41,在接下来的12 h内没有变化。此外,注射NP也不影响动脉PCO 2或[HCO 3-]。NP注射后24小时和96小时,GFR平均值分别为11.0和13.0 ml min-1 g-1,与对照组(14.0和14.0 ml min-1 g-1)具有统计学可比性。NP注射后12- 24小时平均动脉血压(MAP)降低(111 vs 123 min-1),与肠系膜小动脉收缩力降低相关,通过肌造影显示肠系膜小动脉收缩力降低,从而降低内皮功能。总之,我们的研究表明,超顺磁性氧化铁纳米颗粒的积累不会影响健康小鼠的肾功能,但会暂时降低血压。
Acoustic Probing of New Biomarkers for Rapid Sickle Cell Disease Screening
Biomedical Engineering Program, University of Colorado Boulder(科罗拉多大学博尔德分校生物医学工程项目);Materials Science and Engineering Program, University of Colorado Boulder(科罗拉多大学博尔德分校材料科学与工程系);BioFrontiers Institute, University of Colorado, Boulder(科罗拉多大学博尔德分校生物前沿研究所)