We demonstrate a high average power terahertz time-domain (THZ-TDS) spectrometer based on optical rectification in the tilted-pulse front geometry in lithium niobate at room temperature, driven by a commercial, industrial femtosecond-laser operating with flexible repetition rate between 40 kHz - 400 kHz. The driving laser provides a pulse energy of 41 uJ for all repetition rates, at a pulse duration of 310 fs, allowing us to explore repetition rate dependent effects in our TDS. At the maximum repetition rate of 400 kHz, up to 16.5 W of average power are available to drive our THz source, resulting in a maximum of 24 mW of THz average power with a conversion efficiency of ~ 0.15 % and electric field strength of several tens of kV/cm. At the other available lower repetition rates, we show that the pulse strength and bandwidth of our TDS is unchanged, showing that the THz generation is not affected by thermal effects in this average power region of several tens of watts. The resulting combination of high electric field strength with flexible and high repetition rate is very attractive for spectroscopy, in particular since the system is driven by an industrial, compact laser without the need for external compressors or other specialized pulse manipulation.
We report generation of a femtosecond supercontinuum extending from the ultraviolet to the near-infrared and detection of its carrier-envelope phase variation by f-to-2f interferometry. The spectrum is generated in a gas-filled hollow-core photonic crystal fiber where soliton dynamics allows CEP-stable self-compression of OPCPA pump pulses at 800 nm to a duration of 1.7 optical cycles, followed by dispersive wave emission. The source provides up to 1 μJ of pulse energy at 800 kHz repetition rate resulting in 0.8 W of average power, and can be extremely useful for example in strong-field physic…
Deep ultraviolet (DUV) laser pulses with tuneable wavelength and very short duration are a key enabling technology for next-generation technology and ultrafast science. Their generation has been the subject of extensive experimental effort, but no technique demonstrated thus far has been able to meet all requirements in one light source. Here we demonstrate a bright, efficient, and compact source of tuneable deep ultraviolet ultrafast laser pulses based on resonant dispersive wave emission in hollow capillary fibre. In a total footprint of only 120 x 75 cm, including the ytterbium-based drive …
Liquid dye lasers have long been considered as ideal tunable laser sources in the visible range but are bulky, expensive, and require a complex system for dye circulation. Here, we present a system that relies on a low-cost blue laser diode as the pump source and a sealed dye cell with no flowing circuitry, resulting in a device that combines the convenience and size of a solid-state device with the stability of a liquid organic laser. A very high photo-stability is obtained (up to 1.2 x 10$^9$ pulses or 12 days at 1 kHz), which is five orders of magnitude higher than a solid-state dye laser o…
We report the coherent generation and detection of terahertz (THz) pulses covering the bandwidth of 0.1-9 THz in a high repetition rate, low pulse energy laser system. In this work we demonstrate the application and evaluation of solid-state biased coherent detection in combination with a spintronic emitter. This combination was used to generate and detect THz pulses in a time-domain spectroscopy (TDS) setup and tested on bulk nonlinear crystals. These results establish a new promising candidate to extend the possibilities for compact, broadband THz TDS systems driven by high repetition rate l…
We demonstrate a compact source of energetic and phase-locked multi-terahertz pulses at a repetition rate of 190 kHz. Difference frequency mixing of the fundamental output of an Yb:KGW amplifier with the idler of an optical parametric amplifier in GaSe and LiGaS2 crystals yields a passively phase-locked train of waveforms tunable between 12 and 42 THz. The shortest multi-terahertz pulses contain 1.8 oscillation cycles within the intensity FWHM. Pulse energies of up to 0.16 μJ and peak electric fields of 13 MV/cm are achieved. Electro-optic sampling reveals a phase stability better than 0.1 $π$…
Coherent soft x-ray (SXR) sources enable fundamental studies in the important water window spectral region. Until now, such sources have been limited to repetition rates of 1 kHz or less, which limits count rates and signal-to-noise ratio for a variety of experiments. SXR generation at high repetition rate has remained challenging because of the missing high-power mid-infrared (mid-IR) laser sources to drive the high-harmonic generation (HHG) process. Here we present a mid-IR optical parametric chirped pulse amplifier (OPCPA) centered at a wavelength of 2.2 μm and generating 16.5-fs pulses (2.…
A high repetition rate, picosecond THz parametric amplifier (TPA) with a LiNbO3 (LN) crystal has been demonstrated in this work. At 10 kHz repetition rate, a peak power of 200 W and an average power of 12 μW have been obtained over a wide range around 2 THz; at 100 kHz repetition rate, a maximum peak power of 18 W and average power of 10.8 μW have been obtained. The parametric gain of the LN crystal was also investigated and a modified Schwarz-Maier model was introduced to interpret the experimental results.
Time- and angle-resolved photoelectron spectroscopy (trARPES) employing a 500 kHz extreme-ultravioled (XUV) light source operating at 21.7 eV probe photon energy is reported. Based on a high-power ytterbium laser, optical parametric chirped pulse amplification (OPCPA), and ultraviolet-driven high-harmonic generation, the light source produces an isolated high-harmonic with 110 meV bandwidth and a flux of more than $10^{11}$ photons/second on the sample. Combined with a state-of-the-art ARPES chamber, this table-top experiment allows high-repetition rate pump-probe experiments of electron dynam…
We report on a multi-mJ 2.1-$μ$m OPCPA system operating at a 1-kHz repetition rate, pumped by a picosecond cryogenic Yb:YAG pump laser, and the phase-matched high-flux high-harmonic soft X-ray generation.
Time-resolved femtosecond stimulated Raman spectroscopy (FSRS) is a powerful tool for investigating ultrafast structural and vibrational dynamics in light absorbing systems. However, the technique generally requires exposing a sample to high laser pulse fluences and long acquisition times to achieve adequate signal-to-noise ratios. Here, we describe a timeresolved FSRS instrument built around a Yb ultrafast amplifier operating at 200 kHz, and address some of the unique challenges that arise at high repetition-rates. The setup includes detection with a 9 kHz CMOS camera and an improved dual-cho…
We report on an environmentally stable, Yb-doped, all-normal dispersion, mode-locked fibre laser that is capable of creating broadband pulses with ultra-low repetition rates. Specifically, through careful positioning of fibre sections in an all-PM-fibre cavity mode-locked with a nonlinear amplifying loop mirror, we achieve stable pulse trains with repetition rates as low as 506 kHz. The pulses have several nanojules of energy and are compressible down to ultrashort (< 500 fs) durations.
Recently, we introduced a Portable HAndheld Spectral Reflection (PHASR) Scanner to allow THz Time-Domain Spectroscopic (THz-TDS) imaging in clinical and industrial settings using a fiber-coupled and alignment-free telecentric beam steering design. The key limitations of the version 1.0 of the PHASR Scanner were its field-of-view and speed of time-domain trace acquisition. In this paper, we address these limitations by introducing a heliostat geometry for beam scanning to achieve an extended field-of-view, and by reconfiguring the ASynchronous OPtical Sampling (ASOPS) system to perform Electron…
Bright, coherent soft X-ray (SXR) radiation is essential to a variety of applications in fundamental research and life sciences. So far, high photon flux in this spectral region can only be delivered by synchrotrons, free electron lasers or high-order harmonic generation (HHG) sources, which are driven by kHz-class repetition rate lasers with very high peak powers. Here, we establish a novel route toward powerful and easy-to-use SXR sources by presenting a compact experiment, in which nonlinear pulse self-compression to the few-cycle regime is combined with phase-matched HHG in a single, heliu…
A compact pulsed Nd:LuAG laser at 1064 nm based on the self-Q-switching technique is reported, having the output power as high as 6.61 W at the incident pump power of 21.32 W, corresponding to the optical conversion efficiency of ~31 %. The temporal width of the pulse was in the range from 532.2 ns to 652.6 ns, and the repetition rate varied between 488.6 kHz and 551.9 kHz. To the best of our knowledge, this is the first report on the self-Q-switching Nd:LuAG laser. Possible reasons for the self-Q-switching of Nd:LuAG were also provided, and the factor leading to the high repetition rate was a…
We present a near-infrared optical parametric chirped-pulse amplifier (OPCPA) and soft X-ray (SXR) high-harmonic generation system. The OPCPA produces few-cycle pulses at a center wavelength of 800 nm and operates at a high repetition rate of 100 kHz. It is seeded by fully programmable amplitude and phase controlled ultra-broadband pulses from a Ti:sapphire oscillator. The output from the OPCPA system was compressed to near-transform-limited 9.3-fs pulses. High-power operation up to an average power of 35 W was achieved, and a fully characterized pulse compression was recorded for a power leve…
We experimentally demonstrate that the transmission of a 1030~nm, 1.3~ps laser beam of 100 mJ energy through fog increases when its repetition rate increases to the kHz range. Due to the efficient energy deposition by the laser filaments in the air, a shockwave ejects the fog droplets from a substantial volume of the beam, at a moderate energy cost. This process opens prospects for applications requiring the transmission of laser beams through fogs and clouds.
We present efficient high-order harmonic generation (HHG) based on a high-repetition rate, few-cycle, near infrared (NIR), carrier-envelope phase stable, optical parametric chirped pulse amplifier (OPCPA), emitting 6fs pulses with 9μJ pulse energy at 200kHz repetition rate. In krypton, we reach conversion efficiencies from the NIR to the extreme ultraviolet (XUV) radiation pulse energy on the order of ~10^{-6} with less than 3μJ driving pulse energy. This is achieved by optimizing the OPCPA for a spatially and temporally clean pulse and by a specially designed high-pressure gas target. In the …
The output of a 200 kHz, 34 W, 300 fs Yb amplifier is compressed to 31 fs with > 88 % efficiency to reach a peak power of 2.5 GW, which to date is a record for a single-stage bulk multi-pass cell. Despite operation 80 times above the critical power for self-focusing in bulk material, the setup demonstrates excellent preservation of the input beam quality. Extensive beam and pulse characterizations are performed to show that the compressed pulses are promising drivers for high harmonic generation and nonlinear optics in gases or solids.
We report on the development of a high-order harmonic generation (HHG)-based ultrafast high-repetition-rate (250 kHz) monochromatic extreme ultraviolet (21.6 eV) source with polarization tunability, specifically designed for multi-modal dichroism in time- and angle-resolved photoemission spectroscopy. Driving HHG using an annular beam allows us to spatially separate the high-power 515 nm driving laser from the XUV beamlet while preserving the linear polarization axis angle tunability. This enables controlling the polarization state of the XUV radiation with a fixed all-reflective phase-shifter…
High-repetition-rate attosecond pulse sources are indispensable tools of time-resolved studies of electron dynamics, such as coincidence spectroscopy and experiments with high demands on statistics or signal-to-noise ratio, especially in case of solid and big molecule samples in chemistry and biology. Although with the high-repetition-rate lasers such attosecond pulses in a pump-probe configuration are possible to achieve, until now only a few such light sources have been demonstrated. Here, by shaping the driving laser to an annular beam, a 100-kHz attosecond pulse train (APT) is reported wit…
Although ultraviolet (UV) light is important in many areas of science and technology, there are very few if any lasers capable of delivering wavelength-tunable ultrashort UV pulses at MHz repetition rates. Here we report the generation of deep-UV laser pulses at MHz repetition rates and μJ-energies by means of dispersive wave (DW) emission from self-compressed solitons in gas-filled single-ring hollow-core photonic crystal fiber (SR-PCF). Pulses from an ytterbium fiber laser (~300 fs) are first compressed to ~25 fs in a SR-PCF-based nonlinear compression stage, and subsequently used to pump a …
Novel table-top sources of extreme-ultraviolet light based on high-harmonic generation yield unique insight into the fundamental properties of molecules, nanomaterials, or correlated solids, and enable advanced applications in imaging or metrology. Extending high-harmonic generation to high repetition rates portends great experimental benefits, yet efficient extreme-ultraviolet conversion of correspondingly weak driving pulses is challenging. Here, we demonstrate a highly efficient source of femtosecond extreme-ultraviolet pulses at 50-kHz repetition rate, utilizing the ultraviolet second-harm…
We demonstrate a femtosecond pump-probe spectrometer which utilizes a white light supercontinuum as input, and relies on mutual synchronization of acousto-optical chopper, pump-probe delay stage and the CCD camera to record shot-to-shot pump-probe spectra while the pump-probe delay is scanned synchronously with the laser repetition rate. The unique combination of technologies implemented here allows for electronically controllable and repetition-rate scalable detection throughput that is only limited by the camera frame rate. Despite RMS white-light probe fluctuations of ~5.5%, fully leveragin…
We extend the technique of multiplex coherent Raman spectroscopy with two femtosecond mode-locked lasers to oscillators of a pulse repetition frequency of 1 GHz. We demonstrate spectra of liquids, which span 1100 cm$^{-1}$ of Raman shifts. At a resolution of 6 cm$^{-1}$, their measurement time may be as short as 5 microseconds for a refresh rate of 2 kHz. The waiting period between acquisitions is improved ten-fold compared to previous experiments with two lasers of 100-MHz repetition frequencies.
The generation of coherent light pulses in the extreme ultraviolet (XUV) spectral region with attosecond pulse durations constitutes the foundation of the field of attosecond science. Twenty years after the first demonstration of isolated attosecond pulses, they continue to be a unique tool enabling the observation and control of electron dynamics in atoms, molecules and solids. It has long been identified that an increase in the repetition rate of attosecond light sources is necessary for many applications in atomic and molecular physics, surface science, and imaging. Although high harmonic g…
We report a 21-W mid-IR OPCPA that generates 131-μJ and 97 fs (sub-9-cycle) pulses at 160 kHz repetition rate and at a centre wavelength of 3.25 μm. Pulse-to-pulse stability of the CEP-stable output is excellent with 0.33% rms over 288 million pulses (30 min) and compression close to a single optical cycle was achieved through soliton self- compression inside a gas-filled mid-IR anti-resonant-guiding photonic crystal fibre. Without any additional compression device, stable generation of 14.5 fs (1.35-optical-cycle) pulses was achieved at an average power of 9.6 W. The resulting peak power of 3…
We present a laser source delivering waveform-controlled 1.5-cycle pulses that can be focused to relativistic intensity at 1 kHz repetition rate. These pulses are generated by nonlinear compression of high-temporal-contrast sub-25\,fs pulses from a kHz Ti:Sapphire double-chirped pulse amplifier in a stretched flexible hollow fiber compressor scaled for high peak power. The unique capabilities of this source are demonstrated by observing carrier-envelope phase effects in laser-wakefield acceleration of relativistic electrons for the first time.
We demonstrate laser driven acceleration of electrons to MeV-scale energies at 1kHz repetition rate using <10mJ pulses focused on near-critical density He and H2 gas jets. Using the H2 gas jet, electron acceleration to ~0.5MeV in ~10fC bunches was observed with laser pulse energy as low as 1.3mJ. Increasing the pulse energy to 10mJ, we measure ~1pC charge bunches with >1MeV energy for both He and H2 gas jets.
We construct a terahertz time-domain spectrometer (THz-TDS) system based on photoconductive antenna (PCA). A 800 nm Ti sapphire femtosecond laser with 80 MHz repetition rate provides the pump and probe laser pulse, which has a 45 fs pulse width (as short as 15 fs is available) and as much as 400 mW power. Two commercial PCAs with 34 um and 6 um gap size are used as the emitter and receiver, respectively. We characterize this system by measuring its absolute radiated THz power, spectral bandwidth, signal-to-noise ratio (SNR), dynamic range and beam profile at the focal plane. We further analyze…
We present on THz generation in the two-color gas plasma scheme driven by a high-power, ultrafast fiber laser system. The applied scheme is a promising approach for scaling the THz average power but it has been limited so far by the driving lasers to repetition rates up to 1 kHz. Here, we demonstrate recent results of THz generation operating at a two orders of magnitude higher repetition rate. This results in a unprecedented THz average power of 50 mW. The development of compact, table-top THz sources with high repetition rate and high field strength is crucial for studying nonlinear response…
Manipulating the atomic and electronic structure of matter with strong terahertz (THz) fields while probing the response with ultrafast pulses at x-ray free electron lasers (FELs) has offered unique insights into a multitude of physical phenomena in solid state and atomic physics. Recent upgrades of x-ray FEL facilities are pushing to much higher repetition rates, enabling unprecedented signal to noise for pump probe experiments. This requires the development of suitable THz pump sources that are able to deliver intense pulses at compatible repetition rates. Here we present a high power laser-…
The repetition rate stabilization of an optical frequency comb based on diode-pumped solid-state laser technology is demonstrated using an intra-cavity electro-optic modulator. The large feedback bandwidth of such modulators allows disciplining the comb repetition rate on a cavity-stabilized continuous-wave laser with a locking bandwidth up to 700 kHz. This surpasses what can be achieved with any other type of actuator reported so far. An in-loop integrated phase noise of 133 mrad has been measured and the PM-to-AM coupling of the electro-optic modulator has been investigated as well.
Higher repetition-rate optical pulse trains have been desired for various applications such as high-bit-rate optical communication, photonic analogue-to-digital conversion, and multi- photon imaging. Generation of multi GHz and higher repetition-rate optical pulse trains directly from mode-locked oscillators is often challenging. As an alternative, harmonic injection locking can be applied for extra-cavity repetition-rate multiplication (RRM). Here we have investigated the operation conditions and achievable performances of all-fibre, highly tunable harmonic injection locking-based pulse RRM. …
Low loss, optical channel waveguides have been successfully produced by high repetition rate, femtosecond laser inscription in a Li-Zn fluoroborate glass (64.9B2O3 + 25Li2O + 10ZnF2 + 0.1Er2O3). High quality waveguides were produced at 500 kHz, 1 MHz and 2 MHz laser repetition rates, showing a refractive index contrast in the range of 3-6 x 10-3 depending on various fluences. Dependence of experimental parameters such as average laser power, pulse repetition rate and writing speed on the properties of fabricated waveguides has been discussed. The comparison of optical and compositional charact…
The generation of microwaves from optical signals suffers from thermal and shot noise inherent in the photodetection process. This problem is more acute at lower pulse repetition rates where photodiode saturation limits the achievable signal-to-noise ratio. In this paper, we demonstrate a 10-15 dB reduction in the 10 GHz phase noise floor by multiplication of the pulse repetition rate. Starting with a 250 MHz fundamentally mode-locked erbium(Er):fiber laser, we compare two different approaches to repetition rate multiplication: Fabry-Perot cavity filtering and a cascaded, unbalanced Mach-Zehnd…
We report a new technique for the realization of second-order correlation ($g^2(τ)$) measurement under low-repetition-rate pulsed excitation (1 kHz), with timing jitter calibrated to restore lateral $g^2(τ)$ curves and determine $g^2(0)$. We use CdSe nanowire (NW) laser to demonstrate the jitter-calibrated $g^2(τ)$ measurement, where $g^2(0)$ evolution shows the laser emission transition process. The exciting pulses are split into reference and excitation channels, which enables the jitter calibration when the exciting pulses have significant timing jitter and low repetition rate. After using …