arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2207.11961cond-mat.mtrl-sciphysics.chem-ph
收藏

通过金刚石中的P1中心的$^{13}$ C的大型室温本体DNP

Large Room Temperature Bulk DNP of $^{13}$C via P1 Centers in Diamond

Daphna Shimon, Kelly A. Cantwell, Linta Joseph, Ethan Q. Williams, Zaili Peng, Susumu Takahashi, Chandrasekhar Ramanathan

摘要:

我们利用微波诱导金刚石中的替位氮缺陷(P1心)的动态核极化(DNP),在室温3.34 T下超极化单晶和粉末样品中的体$^{13}$ C核。所证明的大的($>100$ -倍)增强对应于在1\%丰度的$^{13}$ C自旋的信号平均方面大于10,000倍的改进。在静态(非旋转)条件下使用低功率固态源进行DNP。金刚石粉末的DNP谱(DNP增强作为微波频率的函数)显示出与EPR谱广泛相关的特征。在$^{14}$ N自旋的中心($m_I=0$)流形上观察到一个明确的负Overhauser峰和两个固体效应峰。以前在金刚石中的低温测量已经测量了该流形中的正Overhauser增强。频率啁啾毫米波激发的电子自旋被认为是显着提高两个外部核自旋流形($m_I = \pm 1$)的增强和模糊的一些尖锐的功能与中央流形。使用交叉效应和截断交叉效应的组合来最好地拟合外部线-已知其模仿Overhauser效应的特征。在单晶样品的实验中也观察到类似的特征。在相同的实验条件下,在单一材料系统中观察到所有这些机制可能是由于所使用的高压高温(HPHT)Ib型金刚石样品的显著不均匀性。在几特斯拉以上的场的大的室温DNP增强使得光谱研究在环境条件下具有更好的化学位移分辨率。

英文摘要:

We use microwave-induced dynamic nuclear polarization (DNP) of the substitutional nitrogen defects (P1 centers) in diamond to hyperpolarize bulk $^{13}$C nuclei in both single crystal and powder samples at room temperature at 3.34 T. The large ($>100$-fold) enhancements demonstrated correspond to a greater than 10,000 fold improvement in terms of signal averaging of the 1\% abundant $^{13}$C spins. The DNP was performed using low-power solid state sources under static (non-spinning) conditions. The DNP spectrum (DNP enhancement as a function of microwave frequency) of diamond powder shows features that broadly correlate with the EPR spectrum. A well-defined negative Overhauser peak and two solid effect peaks are observed for the central ($m_I=0$) manifold of the $^{14}$N spins. Previous low temperature measurements in diamond had measured a positive Overhauser enhancement in this manifold. Frequency-chirped millimeter-wave excitation of the electron spins is seen to significantly improve the enhancements for the two outer nuclear spin manifolds ($m_I = \pm 1$) and to blur some of the sharper features associated with the central manifolds. The outer lines are best fit using a combination of the cross effect and a truncated cross effect -- which is known to mimic features of an Overhauser effect. Similar features are also observed in experiments on single crystal samples. The observation of all of these mechanisms in a single material system under the same experimental conditions is likely due to the significant heterogeneity of the high pressure, high temperature (HPHT) type Ib diamond samples used. Large room temperature DNP enhancements at fields above a few Tesla enable spectroscopic studies with better chemical shift resolution under ambient conditions.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑